Loading...
HomeMy WebLinkAbout2018-08-08 e-packet@6:00Wednesday, August 8, 2018 6:00 PM City of South San Francisco P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA Municipal Services Building, Council Chambers 33 Arroyo Drive, South San Francisco, CA Special City Council Special Meeting Agenda August 8, 2018Special City Council Special Meeting Agenda NOTICE IS HEREBY GIVEN, pursuant to Section 54956 of the Government Code of the State of California, the City Council of the City of South San Francisco will hold a Special Meeting on Wednesday, August 8, 2018, at 6:00 p.m., in the City Council Chambers, Municipal Services Building, 33 Arroyo Drive, South San Francisco, California. Purpose of the meeting: Call to Order. Roll Call. Agenda Review. Public Comments - comments are limited to items on the Special Meeting Agenda. ADMINISTRATIVE BUSINESS Presentation regarding update on the City of South San Francisco’s FEMA Flood Zone Map. (Eunejune Kim, Director of Public Works) 1. Study Session - Update Regarding the Traffic Circle in Avalon Neighborhood (Richard Cho, Principal Engineer) 2. Report regarding General Plan Update overview and process. (Mike Futrell, City Manager and Sailesh Mehra, Chief Planner) 3. Report regarding a resolution approving a Back to Business (B2B) Program and authorizing the City Manager, or his designee, to implement and administer the B2B Program to facilitate the timely inspection of damaged structures in the event of a major disaster. (Phil Perry, Chief Building Official) 4. Resolution approving a Back to Business (B2B) Program and authorizing the City Manager, or his designee, to implement and administer the B2B Program to facilitate the timely inspection of damaged structures in the event of a major disaster. 4a. Adjournment. Page 2 City of South San Francisco Printed on 8/31/2018 City of South San Francisco Legislation Text P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA File #:18-732 Agenda Date:8/8/2018 Version:1 Item #:1. Presentation regarding update on the City of South San Francisco’s FEMA Flood Zone Map. (Eunejune Kim, Director of Public Works) City of South San Francisco Printed on 8/2/2018Page 1 of 1 powered by Legistar™ REVISEDFEMA FLOODINSURANCE RATEMAPS(FIRMS) CHANGING THE 100-YEAR FLOOD PLAIN BOUNDARIES City Participates in the FEMA National Flood Insurance Program (NFIP) Communities that participate in NFIP: •Must adopt and administer a flood plain ordinance •Are eligible for future flood-related financial assistance •Are eligible for flood improvement grants and loans from federal agencies •Property owners in flood plain are assured ability to purchase flood insurance. Such policies cannot be canceled for repeat losses. •In 1968, FEMA began issuing FIRMs identifying land with 1% chance of flooding in any year (100-year flood plain) •In 2012, FEMA digitized and revised its older maps •In 2015, FEMA issued further preliminary revisions based on coastal hazard analyses which City appealed in 2016 •In April 2018, FEMA denied City’s appeal, meaning that the 2015 preliminary FIRMs will become effective next spring •By 2020, newly mapped property owners with federally backed mortgages will need to obtain flood insurance FEMA Actions Impacting the City How the Revised FIRMs will Impact on Properties within the City The revised FIRMs will: •Add 187 new parcels into flood plain •Retain 687 parcels already in the flood plain •Remove 854 parcels from the flood plain 2018 Flood Insurance Rate Maps (FIRMs) Impact on Properties with the City Of the 187 newly added parcels: •36 are single family residential, primary in the Francisco Terrance neighborhood •101 are commercial, including warehouses, parking lots, businesses, biotech, and manufacturing •6 are local government (utilities & SFO airport) •44 are vacant land or underwater marsh Next Steps Notify affected property owners •Send out informational mailer •Hold community meeting(s) Amend City’s flood plain ordinance City of South San Francisco Legislation Text P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA File #:18-714 Agenda Date:8/8/2018 Version:1 Item #:2. Study Session -Update Regarding the Traffic Circle in Avalon Neighborhood (Richard Cho,Principal Engineer) City of South San Francisco Printed on 8/2/2018Page 1 of 1 powered by Legistar™ Av a l o n  – B r e n t w o o d  Ne i g h b o r h o o d Tr a f f i c  Ci r c l e  Up d a t e  No v e m b e r  14 ,  20 1 7  –l o c a t i o n  an d  co n c e p t u a l  design  pr e s e n t e d  at  ne i g h b o r h o o d  me e t i n g    Ja n u a r y  20 1 8  –D e s i g n  fo r  pi l o t  tr a f f i c  ci r c l e  finalized  Fe b r u a r y  20 1 8  –P i l o t  tr a f f i c  ci r c l e  in s t a l l e d Ba c k g r o u n d  Ma x i m i z e  ra d i u s  wh i l e  al l o w i n g  fo r  40 ’  ve h i c l e   tu r n i n g  Ke e p  al l ‐wa y  st o p  co n t r o l  du e  to  AD A  ra m p s  at  co r n e r s  an d  no  cr o s s w a l k s  Tr a f f i c  ci r c l e  sa f e t y  go a l s :  In c r e a s e  st o p  si g n  co m p l i a n c e  Sl o w  ve h i c u l a r  tr a f f i c  th r o u g h  in t e r s e c t i o n De s i g n  Cr i t e r i a   Pi l o t  Tr a f f i c  Ci r c l e   Pa r k i n g R e s t r i c t e d (R e d C u r b ) EV 2 Sl i d e 4 EV 2 In d i c a t e r e d c u r b s Er i n V a c a , 8 / 1 / 2 0 1 8 Pi l o t  Tr a f f i c  Ci r c l e   As  In s t a l l e d  Di f f i c u l t  fo r  pe d e s t r i a n s  to  cr o s s  Ve h i c l e s  in  ci r c l e  do  no t  yi e l d  Pe d e s t r i a n s  un c l e a r  on  wh e r e  to  cr o s s  Mo t o r i s t s  do  no t  si g n a l  tu r n s  co n s i s t e n t l y  Lo s s  of  st r e e t  pa r k i n g  at  ad j a c e n t  pr o p e r t i e s  St o p  si g n  co m p l i a n c e  is  st i l l  a pr o b l e m  Ap p r o a c h  sp e e d s  no t  ad d r e s s e d *  Ve r y  la r g e  ve h i c l e s  ca n n o t  ma n e u v e r  th r o u g h  in t e r s e c t i o n  **  Co n c e r n  ov e r  tr a j e c t o r y  of  ve h i c l e s  as  th e y  cr o s s  in t e r s e c t i o n  (in  ca s e  of  lo s s  of  co n t r o l )  De l i n e a t o r s  ea s i l y  kn o c k e d  ov e r / d a m a g e d  Un p l e a s i n g  ae s t h e t i c s Su m m a r y  of  Co m m u n i t y  Co n c e r n s  Re m o v e  pi l o t  tr a f f i c  ci r c l e  Op t i o n  – r e p l a c e  wi t h  pe r m a n e n t  in s t a l l a t i o n   in c l u d i n g :  Sm a l l e r  di a m e t e r  (l e s s  pa r k i n g  lo s s )  Mo u n t a b l e  ap r o n Ne x t  St e p s Co n c e p t u a l  De s i g n  fo r  Pe r m a n e n t   In s t a l l a t i o n La n d s c a p e d  Tr a f f i c  Ci r c l e  –S a n   Fr a n c i s c o  Ex a m p l e City of South San Francisco Legislation Text P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA File #:18-744 Agenda Date:8/8/2018 Version:1 Item #:3. Report regarding General Plan Update overview and process.(Mike Futrell,City Manager and Sailesh Mehra, Chief Planner) RECOMMENDATION Staff recommends that the City Council receive information regarding the General Plan Update overview and process and provide direction on staff recommended next steps. BACKGROUND/DISCUSSION A General Plan is the local government’s long-term blueprint for the community’s vision of future growth.The General Plan must contain a minimum of seven state-mandated elements: ·Land Use ·Open Space ·Conservation ·Housing ·Circulation ·Noise ·Safety Each city is required by California law to have a General Plan to guide its future land use decisions.Everyday planning decisions should support administration of the General Plan.However,as necessary,General Plan amendments can be administered to address up-to-date policy decisions.State law allows four updates to each General Plan element,annually.Additionally,beyond amendments,General Plans,holistically,should be evaluated and updated as needed to stay relevant to evolving and changing times. DISCUSSION The shelf-life of a General Plan is typically 15 to 20 years.The City of South San Francisco General Plan was adopted in 1999.Now is the right time to prepare a new General Plan.The plan will need to tackle a wide-range of challenging issues,including population growth and change,affordable housing,traffic congestion and climate change.The plan will include the seven mandated elements:Land Use,Open Space,Conservation, Housing,Circulation,Noise,and Safety.Additional elements to be considered are Climate Change,Economic Development and Social Equity. The new plan will be informed by the City’s General Plan Amendments,Housing Element updates,Specific Plans/Area Plans,Parks and Recreation Master Plan,and Development Plan Amendments administered since adoption of the General Plan.It will also be informed by current planning efforts and future goals,requiring thoughtful discussions with City’s residents and businesses.The Planning Commission and City Council will City of South San Francisco Printed on 8/2/2018Page 1 of 4 powered by Legistar™ File #:18-744 Agenda Date:8/8/2018 Version:1 Item #:3. ultimately approve the General Plan and related Environmental Impact Report (EIR). Process and Outreach Development of the General Plan will take approximately two years. The key work tasks are as follows: 2018 ·Obtain consultants to supplement City resources and form the project team; and ·Form a community advisory committee to advise City Council. 2019 ·Kick-off the public process; ·Define existing conditions,assess relevant existing documents,coordinate efforts with plans currently being prepared, and begin technical studies and analysis; ·Prepare land use and policy alternatives ·Conduct community meetings focused on purpose, process, and visioning; and ·Draft land use and policy alternatives and obtain community input. 2020 ·Prepare the draft General Plan and obtain further community input; ·Finalize the General Plan for Planning Commission and City Council approval; and ·Prepare the Draft and Final EIR. Throughout the process,there will be timely Planning Commission and City Council meetings.Public meetings will also be held throughout the process to keep the public informed and relevant input can be sought to inform the plan.Traditional face-to-face gatherings will be utilized as well as social media to maximize public engagement.The website will be enhanced to provide drafts and final materials to the public for information and comments. Project Team and Oversight The project will be directed from the City Manager’s Office.The City Manager’s Office will serve as the core base of this effort to ensure effective cross-department coordination,public outreach,consultant management. The Assistant City Manager (ACM)will direct the project.The ACM is accountable to the City Manager who reports to City Council. Staff recommends establishing an 11-member General Plan Community Advisory Committee (GPCAC)to inform the project team as well as City Council. The recommended membership is as follows: ·City Council (2 members) ·Planning Commission (1 members) ·Parks & Recreation Commission (1 member) City of South San Francisco Printed on 8/2/2018Page 2 of 4 powered by Legistar™ File #:18-744 Agenda Date:8/8/2018 Version:1 Item #:3. ·District Community Resident (5 members, 1 per each City District) ·Business Member (2 members, 1 large and 1 small) The committee would be staffed by the ACM.The GPCAC would collectively provide community insight, based on their particular expertise/knowledge/perspective.It is important to contain the size of the committee to maximize productivity and engagement.Staff recommendation was influenced by the City of San Mateo’s General Plan Advisory Committee which has a membership of nine from City Council (2),Planning Commission (1),Sustainability and Infrastructure Commission (1),Park &Recreation Commission (1),San Mateo United Homeowners Association (1), Business Owners (2), and a Non-profit Organization (1). Specifically for the District Community Resident and Business Member,staff recommends seeking interest from the public through an application process to inform City Council consideration and selection.Staff also recommends City Council appoint two Alternates from the application pool to fill unexpected vacancies.The commitment needed from each member is approximately two years. The ACM will be responsible for directing the project team with support from a “consultant staff”who will serve as the Deputy Project Manager (DPM).Outsourcing is needed as current staffing and workload is committed to other City projects.The ACM and DPM will work hand-in-hand with the Economic and Community Development and Communications departments throughout the process as well as the Parks and Recreation,Public Works,Police and Fire departments.The ACM and DPM will also direct the General Plan consultant team. See Attachment 1 for Project Team Organization Chart. FISCAL IMPACT The cost estimate,based on other cities,is between $1.6 million to $2.2 million.To date,the City’s General Plan fund has a balance of $3.6 million,of which $1 million has been appropriated in the current fiscal year for preparation of the General Plan.Staff proposes to expend up to $70,000 during the remainder of this year to fund the DPM.The DPM will assist the ACM in formalizing the GPCAC,preparing the RFP for the General Plan consulting team and cross-departmental coordination. The total project budget will be determined by the end of the year when the General Plan consultant is selected and agreement negotiated.Staff will return to City Council for additional budget approval to complete this effort. CONCLUSION Staff requests direction from City Council to begin the process for preparing the City’s General Plan. Immediate next steps include: ·Obtaining the Deputy Project Manager; ·Preparing a RFP and selecting the General Plan consultant team; and City of South San Francisco Printed on 8/2/2018Page 3 of 4 powered by Legistar™ File #:18-744 Agenda Date:8/8/2018 Version:1 Item #:3. ·Forming the GPCAC. Attachment: Project Team Organization Chart City of South San Francisco Printed on 8/2/2018Page 4 of 4 powered by Legistar™ Attachment 1 Project Team Organization Chart Community Advisory Committee Project Management ACM / Deputy Project Manager General Plan Consultant Team ECD and Communications City Manager (Legal / ECD Director) City Department Working Group  Parks and Recreation  Public Works  Police  Fire City Council City of South San Francisco Legislation Text P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA File #:18-696 Agenda Date:8/8/2018 Version:1 Item #:4. Report regarding a resolution approving a Back to Business (B2B)Program and authorizing the City Manager, or his designee,to implement and administer the B2B Program to facilitate the timely inspection of damaged structures in the event of a major disaster. (Phil Perry, Chief Building Official) RECOMMENDATION Staff recommends that the City Council adopt a resolution approving a Back to Business (B2B)Program and authorizing the City Manager,or his designee,to implement and administer the B2B Program to facilitate the timely inspection of damaged structures in the event of a major disaster. BACKGROUND/ In the event of a major earthquake or other disaster,the City could be faced with an urgent need to inspect hundreds or even thousands of structures,in order to assess their suitability for safe use and occupancy.Based on past experience with earthquakes in California,staff estimates that,even after a major earthquake,most buildings needing inspection could be quickly deemed safe for re-occupancy,and less than half of them would require any sort of restriction of occupancy (either a red tag or yellow tag).Regardless,there would be a huge number of structures to inspect, and no buildings could be safely reoccupied until they are inspected. In this scenario,the need to conduct safety assessments would quickly overwhelm and far exceed the capacity of the City’s building inspection staff.As a result,there could be an extended period of time when residents would be unable to return to their homes,workers would not be able to report to work,and local businesses would not be able to resume operations, thus leading to further economic and social disruption. In the weeks and months following the 1994 Northridge Earthquake (magnitude 6.8),city building inspectors performed approximately 1,600 safety assessments.Most building departments do not have the ability to perform the multitude of inspections required to get residents back into their homes and people back to their jobs in a short period of time.There is,therefore,a strong need to assemble a team of trained professionals available to assist local governments, along with a program to manage these professionals. In July 1987,the California Governor's Office of Emergency Services (OES),the California Office of Statewide Health Planning and Development (OSHPD),and the Federal Emergency Management Agency (FEMA)jointly awarded the Applied Technology Council (ATC)a contract to develop procedures for post- earthquake safety evaluation of buildings.This led to the development of the ATC-20 report "Procedures for Post-Earthquake Safety Evaluation of Buildings,"which documents procedures and guidelines for the safe evaluation of damaged buildings. Following a disaster,inspectors make safety assessments of facilities in order to determine the condition of City of South San Francisco Printed on 8/2/2018Page 1 of 3 powered by Legistar™ File #:18-696 Agenda Date:8/8/2018 Version:1 Item #:4. Following a disaster,inspectors make safety assessments of facilities in order to determine the condition of buildings and infrastructure and their suitability for safe use and occupancy.These initial assessments are not intended to identify or quantify damage, but to categorize safety of facilities. The ATC-20 standards are written specifically for the structural engineers and building inspectors from city building departments and other regulatory agencies that would be required to make on-the-spot evaluations and decisions regarding continued use and occupancy of buildings.The goal of this safety evaluation is to eventually post every building reviewed either INSPECTED (i.e.apparently safe)or UNSAFE.Buildings posted UNSAFE will normally require repair or demolition. South San Francisco Municipal Code Section 8-1.25 "Safety Assessment Placards,” mandates the following. "The section further authorizes the Building Official and his/her authorized representatives to post the appropriate placard at each entry point to a building or structure upon completion of a safety assessment…Once it has been attached to a building or structure, a placard is not to be removed,altered,or covered until done so by an authorized representative of the Building Official.It shall be unlawful for any person,firm,or corporation to alter,remove,cover,or deface a placard unless authorized pursuant to this section." The convention used to identify safety and risk,as referenced above,are yellow and red tags.Red-tagged means there is an extreme hazard,the building may collapse and it is unsafe for occupancy or entry,except by authorities.Yellow-tagged means a dangerous condition is believed to exist and entry by the owner is permitted only for emergency purposes and only at their own risk.As our local legislation clearly states,only authorized individuals may post or modify safety assessment placards,which regulate the occupancy of all or part of a facility. The Building Official determines who may be designated an authorized representative. DISCUSSION Staff has collaborated with local businesses to develop a proposed Back to Business (B2B)Program (see Attachment 1 to the associated resolution).Last year,staff began meeting with representatives from the local biotechnology community to explore how to expedite the restoration of business activities after a disaster.A number of different approaches used by other communities were examined,and a promising option was identified that is currently being used in San Francisco: the Business Occupancy Recovery Program (BORP). San Francisco’s BORP creates a partnership method for businesses to prepare in advance for the disruption and recovery caused by an earthquake or other disaster.Private sector civil and structural engineers are retained by a business and are pre-certified by the City Building Official to perform safety assessment inspections and post placards on damaged buildings to designate whether they are safe to enter or occupy,in compliance with procedures established by the jurisdiction. If the proposed B2B Program is approved,it will provide benefits to both businesses and the South San Francisco community in general.The Program allows businesses to prepare themselves,setting up agreements City of South San Francisco Printed on 8/2/2018Page 2 of 3 powered by Legistar™ File #:18-696 Agenda Date:8/8/2018 Version:1 Item #:4. Francisco community in general.The Program allows businesses to prepare themselves,setting up agreements between civil or structural engineers in private practice and the City,saving time in the aftermath of a disaster by expediting building inspections.Engineers pre-certified under the B2B Program are granted authority by the City Building Official to determine the safety of buildings after a disaster and to officially post a placard on those building,in accordance with the South San Francisco Municipal Code.Under the Program,the City Building Official retains the authority to overrule the occupancy determinations made by the pre-certified engineers. Experience has shown that after a disaster local government are strained perform safety assessments due to heavy volume and businesses may need to wait for review of their damaged buildings as City inspectors focus first on critical facilities.By reducing the number of buildings city inspectors must visit and assess,this Program provides a great benefit to the larger South San Francisco community.For example,if Amgen were to enter into this program,approximately 30 buildings containing about 5 million square feet would not need to be assessed by city inspectors or engineers.If other businesses chose participate in the B2B Program,then the benefits would be magnified,and more of the City’s scarce inspection resources would be available to inspect residential properties and smaller commercial properties. CONCLUSION Staff recommends the City Council adopt the associated resolution approving the B2B Program and authorizing the City Manager, or his designee, to implement and administer the B2B Program. City of South San Francisco Printed on 8/2/2018Page 3 of 3 powered by Legistar™ City of South San Francisco Legislation Text P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA File #:18-697 Agenda Date:8/8/2018 Version:1 Item #:4a. Resolution approving a Back to Business (B2B)Program and authorizing the City Manager,or his designee,to implement and administer the B2B Program to facilitate the timely inspection of damaged structures in the event of a major disaster. WHEREAS,in the aftermath of a major earthquake or other disaster,there may be an urgent need to assess hundreds or thousands of damaged structures in order to determine the condition of the buildings and infrastructure and their suitability for safe use and occupancy; and WHEREAS,in such a major disaster,the need to conduct safety assessments may be overwhelming and far exceed the capacity of the City’s building inspectors; and WHEREAS,the City of South San Francisco (“City”)wishes to establish a public-private partnership with local businesses,known as the Back to Business (B2B)Program,that would prepare in advance for the disruption and recovery caused as the result of an earthquake or other major disaster; and WHEREAS,the B2B Program would authorize the Chief Building Official to pre-certify qualified inspectors, such as civil and structural engineers or architects from the private sector with current California licenses,who would be retained by private businesses to perform safety assessment inspections on designated buildings listed under the B2B Program; and WHEREAS,the Chief Building Official is authorized to appoint inspectors who will have such powers as delegated by the Chief Building Official pursuant to Section 103.3 “Deputies”of the 2016 California Building Code, as adopted under Chapter 15.08 of the South San Francisco Municipal Code; and WHEREAS,the Chief Building Official is further authorized to make all required inspections and has authority to accept written and certified reports of inspection by approved agencies or individuals pursuant to Section 104.4 “Inspections”of the 2016 California Building Code,as adopted under Chapter 15.08 of the South San Francisco Municipal Code; and WHEREAS,the B2B Program would enable the Chief Building Official and his/her authorized representatives to post the appropriate placard at each entry point to a building or structure upon completion of a safety assessment; and WHEREAS,the extent of responsibility and liability for such inspections would be governed by an agreement between the participating building owner and the pre-certified inspector(s); and NOW,THEREFORE,BE IT RESOLVED by the City Council of the City of South San Francisco that it hereby approves the B2B Program, attached hereto as Exhibit A, and incorporated herein. City of South San Francisco Printed on 8/9/2018Page 1 of 2 powered by Legistar™ File #:18-697 Agenda Date:8/8/2018 Version:1 Item #:4a. BE IT FURTHER RESOLVED by the City Council of the City of South San Francisco that it hereby authorizes the City Manager, or his designee, to implement and administer the B2B Program. BE IT FURTHER RESOLVED by the City Council of the City of South San Francisco that it hereby authorizes the City Manager,or his designee,to make any modifications deemed necessary to effectively implement the B2B Program consistent with the intent of City Council. ***** City of South San Francisco Printed on 8/9/2018Page 2 of 2 powered by Legistar™ EXHIBIT A Attachment 1 To Associated Resolution Back to Business Program August 8, 2018 City of South San Francisco Economic & Economic & Community Development Department BACK TO BUSINESS PROGRAM (B2B) Building Post-Disaster Re-Occupancy Inspection Application Instructions B2B PROGRAM TABLE OF CONTENTS DESCRIPTION & INSTRUCTIONS I. Introduction 3 II. Purpose 3 III. Definitions 3 IV. Preparation 4 V. Inspector Requirements 4 VI. Inspection Dossier 6 VII. Pre-Certification Documentation 7 VIII. Indemnification, Hold Harmless and Immunity 8 IX. Pre-Certification Acceptance 8 X. Activation 8 XI. Placard Management 9 XII. Building Official Verification 10 XIII. Termination 10 APPLICATION FORMS 11-25 Application Checklist Appendix A Request for Pre-Certification Appendix B Structural Inspector Authorization Appendix C Biennial Program Renewal Appendix D Placard Issuance Appendix E Inspection Dossier Appendix F 3 BACK TO BUSINESS (B2B) PROGRAM I. INTRODUCTION After an earthquake, or other disaster such as a fire, flood or terrorist Incident that may have caused damage to buildings and/or property, buildings will be inspected and appropriately posted for re-occupancy or closure utilizing standardized ATC-20 (www.atccouncil.org) inspection and posting procedures. The Chief Building Official will appropriately prioritize public safety above all other concerns. At the same time, affected businesses will seek to minimize business interruption and resume building operations as soon as is safely possible. Some building owners may proactively develop private inspection programs for their buildings to facilitate rapid, individualized, building re-occupancy inspections. The Back to Business (B2B) Program establishes an agreement between owners and tenants, the City and designated certified deputized inspectors to allow private, post-disaster re- occupancy inspection satisfying accepted standards and procedures in response to a locally declared emergency. II. PURPOSE The purpose of a pre-certified inspection program is to provide a prioritized, thorough evaluation of possible damage to a structure by qualified persons familiar with the structural design and life-safety systems of the building. This private inspection program allows rapid decisions regarding the closure or re-occupancy of buildings to be made by individuals pre-certified by the Chief Building Official for a specified property. The program reduces inspection delays and eases the burden of inspection by government entities that may need to focus resources on more severely stressed areas or areas of greater public hazard, which may not include the property of interest to a business. III. DEFINITIONS A. Applicant – Individual or entity in possession of title for land, building, or other item. The owner may be responsible for paying taxes in relation to property. Applicant may also be a lessee or tenant of the property or building authorized by the owner. B. Deputized Inspectors – Person(s) deputized by the City under the B2B program. 4 IV. PREPARATION Applicants may request participation in this program at any time except 60 days following a local declared disaster. A building designated as having met the requirements outlined herein shall be placed on a list of buildings accepted for private re-occupancy inspection. Applicants may participate in this program, subject to the requirements listed below: A. Select inspection team; B. Develop inspector response plan(s) and compile building structural drawing(s), safety plan template(s), equipment and drawing location(s), and other pertinent information; arrange for submission or electronic posting of documentation availability to the City; C. Assemble the Inspection Dossier located in Section VI. D. Obtain, document, and store safety and inspection equipment/supplies; E. Update inspection plan, supplies, team member changes, and training as necessary; F. Submit the Biennial Program Renewal form before each biennial anniversary of initial approval date (Appendix D). V. INSPECTOR REQUIREMENTS Applicant will partner with structural inspector(s) to assemble an Inspection Team and to apply for B2B program pre-certification. The structural inspector shall be a Civil or Structural Engineer licensed in the State of California. Additional architect(s) or engineer(s) trained in ATC-20 procedures (www.atcouncil.org) may be pre-certified to supplement the inspection team as required. Though architects may consider structural inspections outside their purview, architects can add expertise to an inspection team by addressing nonstructural hazards such as blockage of exits, facade and ceiling assembly hazards and life-safety system performance. Engineers/architects experienced with historical structures should be considered for the inspection of historic buildings. In accordance with Section 103.3 “Deputies” of the California Building Code, as adopted under Ch apter 15.08 of the South San Francisco Municipal Code , the Chief Building Official has authority to appoint inspectors who will have such powers as delegated by the Chief Building Official. Further Section 104.4 “Inspections” of the California Building Code, the Chief Building Official is authorized to make all of the required inspections and has authority to accept written and certified reports of inspection by approved agencies or individuals. The extent of responsibility and liability is governed by the agreement between the Applicant and inspectors. 5 A. Minimum Qualifications and Requirements 1. Structural Inspectors a. Current California license as a professional civil or structural engineer or architect; b. Relevant experience in the structural design and/or inspection of similar buildings; c. Demonstrated proficiency in ATC-20 Rapid and Detailed Evaluation Procedures. B. Required documents, Equipment and Supplies 1. Copy of Building Inspection Dossier; 2. Structural, architectural, and/or life-safety system drawings; as-built drawings; or, if structural drawings are unreadable, incomplete, or do not exist, a clear written description of the structural system and any known weaknesses and unique features; 3. Personal safety equipment including hardhat, etc., defined by Applicant or inspector company safety officer; 4. Inspection equipment including flashlights, measuring devices, ladders, and other applicable items; 5. ATC-20 Rapid and Detailed Evaluation forms (latest edition) for reporting inspection findings to the Chief Building Official; 6. Yellow Caution and Red Danger tape or barricades; 7. Portable radios or other communication devices for large buildings, if applicable. 8. Sufficient green, yellow, and red official City safety assessment placards to allow appropriate posting at each entrance to the building, to be supplied by City upon approval of application. 6 VI. INSPECTION DOSSIER Applicant or each Inspector, as defined in written company program, shall maintain hard and electronic copies of the Inspection Dossier, and the Dossier shall be readily available to each Inspector for use and reference following a triggering event. The Dossier shall include the following Information: A. Emergency Notification Contact List of the Building B2B Inspection Team Members 1. Licensed engineers/architects certified for structural inspection; 2. Applicant’s site workers responsible for the building; B. Building Information 1. Photograph of building; 2. Address; 3. Description of building including year of original occupancy, number of stories, size, materials of construction, and structural system type; 4. Building floor plans showing entrances, evacuation routes, and recommended locations for observation; 5. Number and location of building entrances per building to be posted with safety assessment placards; 6. Specified building use(s) (e.g., offices, apartments, manufacturing, etc.); 7. Description of life-safety system including location of emergency power generator; 8. Description of building fire detection and suppression systems; 9. Description and locations of potential falling hazards; C. Emergency Response Requirements and Information 1. Trigger for activation of emergency response (earthquake, fire, flood or terrorist incident that may have impacted buildings or property); 2. Rally location for the Applicant’s emergency response and command and control organization; 3. Access procedures and/or location of keys for entrance to the site and all building areas; 4. Inventory and location of required documents, equipment and supplies; 5. Location, type, and handling instructions for any hazardous material. 7 D. Inspection Procedure 1. ATC-20 Procedures for Post-Earthquake Safety Evaluation of Buildings including Rapid and Detailed Evaluation Procedure. Recommended methodology for welded steel joint inspection is FEMA 352 where required. These inspections may be required by the Structural Inspector(s) or the City of South San Francisco. For special inspection or materials testing, use only inspectors pre-certified by the City. 2. Fire/Life-Safety System Checklist (if applicable); 3. Instructions or drawings indicating where to look, what to look for; and to re- inspect following aftershocks; VII. PRE-CERTIFICATION DOCUMENTATION Pre-certification must occur before the incident. No applications for pre-certification will be accepted for a period of at least 60 days after a declared state of emergency. Exceptions may apply only due to limited City resources and the nature of the emergency. Applications may be accepted before the 60 day period ends at the discretion of the Chief Building Official; however, business shall not expect applications to be reviewed during a locally declared emergency. Submit the following to the Building Division: A. Completed B2B Application Checklist (Appendix A); B. Request for Pre-Certification form signed by Applicant (Appendix B); C. Inspection Authorization form providing evidence of qualifications for the Inspection Team (Appendix C); 1. Signed Inspector Authorization form (Appendix C) showing current California License Number as a professional civil or structural engineering or architect and relevant experience in the structural design and/or inspection of buildings of similar size, construction, and complexity; 2. One-page resume describing education and experience relevant to inspection duties. D. Copy of Inspection Dossier or link to electronic file (Appendix F, see content requirements [Section VI.]). 8 VIII. INDEMNIFICATION AND HOLD HARMLESS Each party in the B2B Program agrees to defend, indemnify, hold harmless every party, including the City of South San Francisco, its officers, agents and members of each other party departments and agencies, from all liability, damage (whether in contract or tort), including personal injury, death at any time, or property damage, costs and financial loss, including all costs and expense of litigation, for the sole wrongful or negligent acts or omissions of the indemnifying party’s officers, agents or department members in the performance of any services described in this Agreement that cause such liability, damage, costs and financial loss. If the injury, death or loss that forms the basis of any claim, suit or judgment is determined to have been caused by the combined negligent or willful acts or omissions of more than one party in the performance of any services described in this Agreement, each such party agrees to bear its respective share of the payment of any award, settlement, or judgment, and each such party shall bear its own costs of defense, including attorneys’ fees. Pursuant to California Code Section 8655, etc. seq., the state or its political subdivisions shall not be liable for any claim upon the exercise or performance, or the failure to exercise or perform, a discretionary function or duty on the part of a state or local agency or any employee of the state or its political subdivisions in carrying out the provisions of the California Services Act. IX. PRE-CERTIFICATION ACCEPTANCE Application for the B2B Program will be reviewed by the Chief Building Official and determination will be made within 14 business days after submittal. The Building Division will add the building to the list of buildings approved for the B2B Program and provide the following upon acceptance of pre-certification documentation: A. Building Official-signed Appendix A, Checklist, accepting the Inspection Dossier; B. Building Official-signed Appendix B, Request for Pre-certification form; C. Building Official-signed copy of each Appendix C, Inspector Authorization form; D. Official placards for posting at predetermined building entrances; E. Certificate of approval. X. ACTIVATION A. Upon proclamation of a local emergency that may have caused damage to buildings and/or property, initiate and direct the inspection program as agreed between Applicant and pre-certified deputized Inspection Team; B. Contact the City Building Division at (650) 829-6670 immediately if building or area (including sidewalk, street, or parking area) presents a public safety hazard, or if emergency demolition or shoring is required; 9 C. Arrange for barricading or taping off of all unsafe areas. Contact the City Public Works Department at (650) 877-8550 immediately if areas barricaded include a public street or otherwise adversely affect City services, or if barricades available to Applicant are insufficient; D. Complete rapid inspection per ATC-20 only rapid evaluation adequate to placard unless concerns observed, then proceed to detailed evaluation as soon as reasonably possible, if required. E. Take preventive measures regarding gas leaks, hazardous material spills, or other life-safety mitigation F. Post building (green, yellow, or red) at the main entry of the building and at all entrances of multi-entrance buildings. Elevator and life-safety inspection may occur separately from structural inspection; G. Submit ATC-20 Rapid and/or Detailed Evaluation Report signed and dated by pre-certified deputized Inspector to the Building Division as soon as reasonably practical, preferably within 72 hours of the declared local emergency. Note: If reports are not received within 72 hours, an inspection may be made by City building inspectors or deputized volunteer inspectors using standard City-wide inspection criteria. XI. PLACARD MANAGEMENT Safety Assessment placards are controlled documents and recipients must carefully manage their storage and use. Applicants and Inspectors must adhere to the following protocol in order to participate in the B2B program: A. Placards must be stored in a locked and secure location accessible only to the Applicant and designated Inspector(s); B. Each placard must clearly display a unique identification number assigned by the City of South San Francisco; C. Applicant and/or Inspector must carefully document the posting of every safety assessment placard. Documentation must include placard identification number, building address and entrance where posted, date and time of posting, and name of pre-certified Inspector who authorized the placard posting by the Inspection Team. This information must be provided to the Chief Building Official along with the Inspection documentation. D. Placards shall not be destroyed or discarded. If a placard is erroneous, damaged, or is superseded, the Inspector shall fully mark the front of the placard with an "X", and return the placard to the Chief Building Official. 10 Important: Failure to follow the protocol for safety assessment placards may result in termination from the B2B Program. XII. BUILDING OFFICIAL VERIFICATION The City Building Division in the Economic & Community Development Department may perform inspection of the B2B designated building under any of the following conditions: A. The Inspector has reported the building unsafe and has posted it with a red placard; B. There is reason to believe that unsafe conditions exist; C. Applicants, tenants, other public agencies, or members of the general public express specific concerns. XIII. TERMINATION Before each biennial anniversary of original approval date, a courtesy reminder notice will be sent to the Applicant via email. If there is no response from the Applicant within 180 calendar days, or for one or more of the following reasons, the building may be removed from the B2B Program: A. Biennial renewal forms have not been submitted; B. Partnership or agreement between Applicant and inspection team has been terminated; C. Changes in inspection team members have not been submitted and/or do not meet minimum requirements; D. Alterations made to the building affecting seismic response or inspection procedures have not been reflected in the Inspection Dossier; E. Placards have not been properly managed. 11 APPENDIX A APPLICATION CHECKLIST Building Address/Location and Number: Appendix A: This Checklist, marked by applicant to show all items submitted Appendix B: Request for Pre-certification - signed by Applicant Appendix C: Inspector Authorization - signed, include one form for each inspector, with 1-page resume Appendix D: Biennial Program Renewal Form Appendix E: Copy of Complete Inspection Dossier or link to electronic filing, including: Part A. List of Individual’s Contact Information for this building 1. Licensed engineers applying for pre-certification as re-occupancy inspectors for structural inspection Part B. Building Information 1. Photograph of building 2. Address 3. Description of building, including year of original occupancy, number of stories, size, materials of construction, and structural system type 4. Building floor plans showing entrances; evacuation routes; stairs; elevators; and recommended locations of observation for detecting structural distress 5. Number of building entrances to be posted with City placards 6. List of building use(s) - offices, apartments, manufacturing, etc. 7. Description of life-safety system including location of emergency power generator with description of building fire detection and suppression systems. 8. Description and locations of potential falling hazards, noted on drawings or other documentation 12 Part C: Response requirements and information, including: 1. Trigger for activation of response (earthquake, fire, flood or terrorist incident that may have impacted buildings or property) 2. Rally location for the Applicant’s emergency response and command and control organization; 3. Access procedures and/or location of keys for entrance to the site and all building areas; 4. Inventory and location of required documents, equipment and supplies, including: a. Structural, architectural, and/or life-safety system drawings; as-built drawings, or (if structural drawings are unavailable or otherwise inadequate) a clear description of the structural system and any known weaknesses and unique features b. Personal safety equipment including hardhat c. Inspection equipment including flashlights, measuring devices, ladders, other applicable items d. ATC-20 Rapid and Detailed Evaluation Forms (latest edition) for reporting inspection findings to the Chief Building Official e. Caution/Danger tape and/or barricades f. Handheld radios or other communication devices for large buildings, if applicable 5. Location, type, and handling instructions for hazardous response plan material 13 Part D: Inspection procedure, including: 1. Latest edition of ATC-20-1 Field Manual for Post-Earthquake Safety Evaluation of Buildings including Rapid and Detailed Evaluation Procedures 2. [Optional] Accelerometer placement - may reduce requirement for inspection of welded joints Completed By Applicant Name/Date: Reviewed & Accepted by Chief Building Official Name/Date: RETURN ONE COPY OF THIS FORM TO APPLICANT AFTER REVIEW & ACCEPTANCE Last Updated Date: Original Approval Date: 14 APPENDIX B REQUEST FOR PRE-CERTIFICATION When used for Biennial Renewal, complete only if Applicant has changed during last year. Company Name, Building Address/Location and Number: is hereby requested for acceptance in the City B2B Program. I certify that: 1. The Owner of the building at the above address is: Applicant’s Address: Applicant Phone: Applicant E-Mail: 2. I am the Building owner or I am authorized to act as the Owner's agent in requesting participation in program. 3. The enclosed or linked Pre-Certification Documentation and Inspection Dossier comply with the minimum requirements of the City’s B2B Program. 4. Inspectors have been given access to a copy of the Inspection Dossier for the building at the address listed above. 5. Inspectors have been given instructions regarding obtaining accompanied access or have been provided a means of access to all areas of the building at all times of day and night if safe. Business emergency command/site crisis management teams responsible for respective buildings at the time must authorize entry and track deployment and return of Inspection Teams. 6. Inspectors have access to the most recent accurate copies of all relevant structural, architectural, and life-safety drawings at all times, if available, or maintain detailed layout plans with information necessary to complete inspection, including entrances, evacuation routes, stairs, elevators, and recommended locations of observation for detecting structural distress. 7. All Inspectors will receive immediate notification of any changes in factors affecting the Inspection Dossier (e.g. changes to contact information, structural or life-safety systems, access to buildings, etc.). 15 Certified by: Signature of Applicant Date: Print/Type Name Company Do Not Write Below/For Use of Authorizing Building Official Only [ ] The pre-certification documentation for this building has been accepted by the City Building Division in the Economic & Community Development Department. The building will be placed on the list of buildings for the B2B Program. Accepted by: Name: Date: RETURN ONE COPY OF THIS FORM TO APPLICANT AFTER REVIEW & ACCEPTANCE Last Updated Date: Original Approval Date: 16 APPENDIX C STRUCTURAL INSPECTOR AUTHORIZATION When used for biennial renewal, complete only for NEW Inspectors. Inspector Name: Inspector’s Phone: Company: Inspector’s Email: I request pre-certification as a Structural Inspector for the building located at: Address: I am a ( ) structural engineer; ( ) civil engineer; ( ) architect, licensed in the State of California. License No. Exp. Date I am applying to be a Structural Inspector for this building. Note: Primary Structural Inspector must be a California licensed structural or civil engineer. Attach 1-page resume to this Appendix for each Structural Inspector; including education and experience relevant to inspection duties, in addition to brief experience descriptions below. I certify that: 1. I have relevant experience in the design and/or inspection of similar buildings: Building Address Building Type No. stories 2. I have completed training in ATC-20 Rapid and Detailed Evaluation Procedures and will complete any additional and/or refresher training in a manner consistent with maintaining readiness. ID # Exp. Date: 17 I understand that while I am acting as an Inspector under this B2B agreement, my activities are in no way affiliated with the Cal-EMA Safety Assessment program and I am not entitled to worker's compensation benefits or limited immunity from liability provided by the State of California Disaster Service Worker Volunteer Program. 3. I am familiar with and have access to a complete and current copy of the Inspection Dossier for this building. 4. I am familiar with and will adhere to the management protocol for Safety Assessment Placards. 5. I accept authorization as a Deputized Inspector by the City Building Division upon emergency declaration and will present this form upon request. Signature Date: Do Not Write Below/For Use of Authorizing Building Official Only The individual listed above is certified as a deputized Inspector for the above-listed building by the City Building Division in the Economic & Community Development Department and is authorized to post this building with official City post-disaster safety assessment re- occupancy placards. All evaluations and placard postings by designated Inspectors are subject to review by the Chief Building Official, and ultimate occupancy posting is at the sole discretion of the Chief Building Official. Accepted by: Date: RETURN ORIGINAL OF THIS FORM TO APPLICANT AFTER REVIEW & ACCEPTANCE APPLICANT TO GIVE ORIGINAL TO INSPECTOR FOR IDENTIFICATION PURPOSES Last Updated Date: Original Approval Date: 18 APPENDIX D BIENNIAL PROGRAM RENEWAL TO BE SUBMITTED BIENNIALY PRIOR TO ANNIVERSARY OF DATE OF ORIGINAL APPROVAL Applicant Name(s): Building Address/Location and Number: ( ) No change has been made to any element of Inspection Dossier. ( ) All equipment and supplies for the program have been checked and updated as necessary. ( ) The Applicant has/have changed. The Applicant is A Request for Pre-Certification form completed and signed by the new owner is enclosed. ( ) Inspector/ has changed. Completed Inspector Authorization forms for all new inspectors are enclosed, and Inspection Dossier has been updated and a copy/link provided herewith. ( ) Changes have been made to the building affecting the Inspection Dossier. Inspectors have been provided access to revised drawings for all relevant changes to the building. Inspection Dossier has been updated and a copy/link provided herewith. Designated contact person for biennial update (Applicant): Signature: Date: Print/Type Name: Phone: Company: 19 Do Not Write Below/For Use of Authorizing Building Official Only The updated documentation for this building has been accepted by the City Building Division in the Economic & Community Development Department. The building remains on the list of buildings for the B2B Program. Accepted by: Title Date: Last Updated Date: Original Approval Date: 20 APPENDIX E PLACARD ISSUANCE TO BE COMPLETED BY BUILDING OFFICIAL Applicant Name: Building Address/Location and Number: The following Safety Assessment Placards have been issued to the Applicant: Placards Quantity Identification Numbers (Range) Red (Unsafe- No Entry) Yellow (Restricted Use) Green (Inspected - Lawful Occupancy Permitted) ( ) Each Pre-certified Deputy Inspector has confirmed understanding of placard management protocol and has indicated intent to adhere to protocol by signing the Structural Inspector Authorization form. Building Official Signature: Date: Last Updated Date: Original Approval Date: 21 CITY OF SOUTH SAN FRANCISCO ECONOMIC & COMMUNITY DEVELOPMENT DEPARTMENT B2B PROGRAM APPENDIX F INSPECTION DOSSIER (Attach Complete Dossier or Attach Link) 2958272.1