Loading...
HomeMy WebLinkAboutOrd 940-1984 ORDINANCE NO. 940-84 AN ORDINANCE ADDING SECTION 15.08.095 TO THE SOUTH SAN FRANCISCO MUNICIPAL CODE WHICH ADDS SUBSECTION 1707(d) TO THE UNIFORM BUILDING CODE THE CITY COUNCIL OF THE CITY OF SOUTH SAN FRANCISCO DOES ORDAIN AS FOLLOWS: SECTION 1. SECTION 15.08.095 ADDED. Section 15.08.095 is hereby added to the South San Francisco Municipal Code and shall read as follows: "15.08.095 Subsection 1707(d) Added - Exterior Metal Hardware, Galvanizing Required. Subsection 1707(d) is added to read as follows: "1707(d) Metal railings, cabinets, bolts, nails, hinges, locks and any similar parts exposed to weather on buildings shall be galvanized. Galvanizing of products fabricated from rolled, pressed and forged steel shapes, plates, bars and strip 1/8-inch thick or thicker, shall conform to the specifications of ASTM Designation: A123. Except for pregalvanized standard pipe, galvanizing of material 1/8-inch thick or thicker shall be performed after fabrication into the largest practical sections. Material thinner than 1/8-inch shall either be galvanized before fabrication in conformance with the requirements of ATSM Designation: A525, Coating Designation G210 or after fabrication, in conformance with the requirements of ASTM Designation: A123, whichever results in the greatest resistance to rust, except that the weight of zinc coating shall average not less than 1.2 ounces per square foot of actual surface area with no individual specimen having a weight of less than 1.0 ounce. Galvanized surfaces that are abraded or damaged at any time after the application of the zinc coating shall be repaired by thoroughly wire brushing the damaged areas and removing all loose and cracked coating, after w~ich the cleaned areas shall be painted with 2 applications of Zinc-Rich Primer without thinner. Galvanizing is not required for stainless steel, non-ferrous metals and similar equally corrosion resistant metals." SECTION 2. URGENCY MEASURE. This Ordinance is declared to be an urgency measure adopted pursuant to the provisions of Government Code Section 36937 in that it is for the immediate preservation of public health and safety because it provides needed regulations to prevent the installation on structures of exterior hardware (including, but not limited to, stairway handrails, hinges, etc.) which is likely to rust, deteriorate and become unsafe because said hardware is constructed of ferrous metals which have not been galvanzized SECTION 3. PUBLICATION AND EFFECTIVE DATE. This Ordinance shall be published once as required by law in the Enterprise-journal a newspaper of general circulation in the City of South San Francisco and shall take effect as an urgency measure immediately upon its approval. 2 Passed and adopted as an urgency Ordinance of the City of South San Francisco in accordance with Government Code Section 65858 at a regular meeting of the City Council of the City of South San Francisco this llth day of January , 1984, by the following vote: AYES: Councilmembers Mark N. Addieqo, Emanuele N. Damonte, Richard A. Haffey, Gus Nicolopulos; and Roberta Cerri Teqlia None NOES: ABSENT: None City Clerk As Mayor of the City of South San Francisco, I do hereby approve the foregoing Ordinance this llth day of January , 1984.