Loading...
HomeMy WebLinkAbout12-19-24 Zoning Administrator Agenda PacketThursday, December 19, 2024 2:00 PM City of South San Francisco P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA Annex Conference Room, 315 Maple Avenue, South San Francisco Zoning Administrator Regular Meeting Agenda 1 December 19, 2024Zoning Administrator Regular Meeting Agenda WELCOME If this is the first time you have been to a Zoning Administrator meeting, perhaps you'd like to know a little about our procedure. Please note that this meeting is being conducted in-person only. PUBLIC COMMENTS: Members of the public wishing to participate are encouraged to submit public comments in writing in advance of the meeting. Please email comments to [email protected]. The City encourages the submission of comments by 1:00 p.m. on the date of the meeting to facilitate inclusion in the meeting record. Written or recorded comments received prior to 1:00pm on the day of the meeting will be included as part of the meeting record but will not be read aloud at the meeting. Written or recorded comments received after 1:00pm on the day of the meeting will not be included as a part of the meeting record and will not be read aloud at the meeting. How to provide Public Comment during the meeting: COMMENTS ARE LIMITED TO THREE (3) MINUTES PER SPEAKER During a meeting, comments can only be made in person: Complete a Speaker Card. Be sure to indicate the Agenda Item # you wish to address or the topic of your public comment. When your name is called, please state your name and address (optional) for the Minutes. Any interested party will have 15 calendar days from the date of an action or decision taken by the Zoning Administrator to appeal that action or decision to the Planning Commission by filing a written appeal with the Planning Division as provided under Chapter 20.570 of the South San Francisco Municipal Code. In the event an appeal period ends on a Saturday, Sunday, or any other day the City is closed, the appeal period shall end at the close of business on the next consecutive business day. If any interested party, other than the applicant, wishes to obtain a copy of a Notice of Action for any Zoning Administrator action or decision at a hearing, the interested party must file a written request of such notification with the Planning Division in advance of that Zoning Administrator hearing. If you challenge in court the action taken by the Zoning Administrator regarding the items described below, you may be limited to raising only those issues you or someone else raised at the public hearing described in this notice or in written correspondence delivered to the Zoning Administrator at, or prior to, the public hearing. When the meeting is not in session, staff is available to answer your questions during normal business hours at the Planning Division Public Counter, City Hall Annex, 315 Maple Avenue by telephone at (650) 877-8535 or by e-mail at [email protected]. Page 2 City of South San Francisco Printed on 12/11/2024 2 December 19, 2024Zoning Administrator Regular Meeting Agenda American with Disabilities Act The City Clerk will provide materials in appropriate alternative formats to comply with the Americans with Disabilities Act. Please send a written request to City Clerk Rosa Govea Acosta at 400 Grand Avenue, South San Francisco, CA 94080, or email at [email protected]. Include your name, address, phone number, a brief description of the requested materials, and preferred alternative format service at least 72-hours before the meeting. Accommodations: Individuals who require special assistance of a disability-related modification or accommodation to participate in the meeting, including Interpretation Services, should contact the Office of the City Clerk by email at [email protected], 72-hours before the meeting. In accordance with California Government Code Section 54957.5, any writing or document that is a public record, relates to an open session agenda item, and is distributed less than 72 hours prior to a regular meeting will be made available for public inspection in the City Clerk’s Office located at City Hall. If, however, the document or writing is not distributed until the regular meeting to which it relates, then the document or writing will be made available to the public at the location of the meeting, as listed on this agenda. The address of City Hall is 400 Grand Avenue, South San Francisco, California 94080. Please turn off Cellular Phones, Pagers and other electronic equipment. Page 3 City of South San Francisco Printed on 12/11/2024 3 December 19, 2024Zoning Administrator Regular Meeting Agenda CALL TO ORDER PUBLIC COMMENT Members of the public may speak on any item not listed on the Agenda, and on any items listed under the Consent Calendar. Pursuant to the provisions of the Brown Act, no action may be taken on a matter unless it is written on the agenda, or unless certain emergency or special circumstances exist. Written comments received prior to 1:00 pm on the day of the meeting will be included as part of the meeting record, but will not be read aloud. PUBLIC HEARING Report regarding consideration of a Minor Use Permit to allow six-foot-tall fencing and gates at 1333 Lowrie Avenue in the Mixed Industrial High (MIH) Zoning District in accordance with Title 20 of the South San Francisco Municipal Code (SSFMC) and determination that the project is categorically exempt from CEQA, per Class 1, Section 15301. (Victoria Kim, Associate Planner) 1 Attachment 1_Draft Findings Attachment 2_Conditions of Approval Attachment 3_Project Plans Attachments: Report regarding consideration of a Minor Use Permit to allow handicraft/custom manufacturing and clean technology uses at 619 Airport Boulevard and 111 Pine Avenue in the T3 Corridor (T3C) Zoning District in accordance with Title 20 of the South San Francisco Municipal Code, and determination that the project is categorically exempt from CEQA. (Stephanie Skangos, Senior Planner) 2 Attachment 1 - Draft Findings of Approval Attachment 2 - Draft Conditions of Approval Attachment 3 - Project Plans Attachments: ADJOURNMENT Page 4 City of South San Francisco Printed on 12/11/2024 4 City of South San Francisco Legislation Text P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA File #:24-1159 Agenda Date:12/19/2024 Version:1 Item #:1 Report regarding consideration of a Minor Use Permit to allow six-foot-tall fencing and gates at 1333 Lowrie Avenue in the Mixed Industrial High (MIH)Zoning District in accordance with Title 20 of the South San Francisco Municipal Code (SSFMC)and determination that the project is categorically exempt from CEQA, per Class 1, Section 15301. (Victoria Kim, Associate Planner) MOTION TO ADOPT STAFF RECOMMENDATIONS 1.Move to determine the project is exempt from CEQA. 2.Move to approve the planning entitlements subject to the attached Findings and Conditions of Approval. RECOMMENDATION Staff recommends that the Zoning Administrator conduct a public hearing and take the following actions: 1.Determine that the Project is categorically exempt under the provision of CEQA,Class 1,Section 15301, Existing Facilities. 2.Approve the entitlements request for Projects P24-0117 and MUP24-0002,subject to the attached Findings and Conditions of Approval. BACKGROUND/DISCUSSION The City of South San Francisco received the Minor Use Permit application in November,2024 for an installation of a new six-foot-high picket fence,two vehicle access gates,and one pedestrian gate.The project site is currently used as a storage and warehouse building (UOVO Art Storage)and the proposed fence and gates would be ancillary to the existing use on the subject site. Site Overview The project property is located at 1333 Lowrie Avenue and is approximately 80,000 square feet (1.84 acres)in total area.There is an existing single-story warehouse building and a parking area.The building on the site is 55,000 square feet and approximately 20 feet in height.The existing surface parking area is in the south portion of the site with 32 standard parking spaces and two accessible parking stalls,totaling 34 parking spaces.There are two vehicle accesses to the project site which are from Lowrie Avenue in the south (Ref. Attachment 3). Proposed Project The applicant,Lowrie Ave LLC,is proposing six-foot-high fencing,one pedestrian gate,and two vehicular access gates to enclose the parking area and the facility entrance,but the loading area on the southeast would remain open without any enclosure.The proposed vehicular swing gates would be also six feet in height and 24 feet wide,and the pedestrian gate would be three feet wide and six feet tall.There is no change of the existing building, parking layout, and landscape areas. ZONING CONSISTENCY The project site is located within the Mixed Industrial High (MIH)Zoning District,which is intended for manufacturing,processing,warehousing,storage and distribution,and service commercial uses.The proposedCity of South San Francisco Printed on 12/11/2024Page 1 of 2 powered by Legistar™5 File #:24-1159 Agenda Date:12/19/2024 Version:1 Item #:1 manufacturing,processing,warehousing,storage and distribution,and service commercial uses.The proposed fence and gates are incidental to the primary use of the existing storage and warehouse building. Pursuant to SSFMC Section 20.330.006 (Fences,Walls and Hedges),fences exceeding four feet in height and located within the required front and street-facing side setback are required to be transparent and subject to approval of a Minor Use Permit.The proposed vertical picket (transparent)fence and gates are six feet in height and located in the minimum 20 feet front setback area.Thus,the applicant requested Minor Use Permit approval to allow the six-foot-tall fencing and gates in the minimum front setback. GENERAL PLAN CONSISTENCY The project site is in the Lindenville sub-area located in the central southern portion of South San Francisco between US Highway 101 and South Spruce Avenue.The land use designation for the project site is Mixed Industrial High.The land use vision for this area of Lindenville is intended to preserve small businesses and industrial uses primarily occupied by warehousing,transportation,and industrial services.The existing storage warehousing building is considered an industrial use that will maintain the purpose of Lindenville.The proposed new six-foot-high fences and gates would not be detrimental to the existing neighborhood and are consistent with the intent of the General Plan. ENVIRONMENTAL REVIEW The project has been determined to be categorically exempt under the provisions of CEQA,Class 1,Section 15301,Existing Facilities.The project is ancillary to the existing storage and warehouse building.There is no expansion of the existing use, and the developed property would remain an industrial use. CONCLUSION The proposed project is consistent with the requirements of City’s Municipal Code,General Plan,and Zoning Development Standards.Staff recommends that the Zoning Administrator find that the Project is categorically exempt under the provision of CEQA,Class 1,Section 15301,Existing Facilities and approve the Minor Use Permit (MUP24-0002)to allow the six-foot-high fences and gates at 1333 Lowrie Avenue based on the attached draft Findings and draft Conditions of Approval. Attachments: 1.Draft Findings 2.Draft Conditions of Approval 3.Project Plans City of South San Francisco Printed on 12/11/2024Page 2 of 2 powered by Legistar™6 1 DRAFT FINDINGS OF APPROVAL P24-0117: MUP24-0002 1333 LOWRIE AVENUE (As recommended by City Staff on December 19, 2024) As required by the Use Permit Procedures (SSFMC Chapter 20.490), the following findings are made in support of a Minor Use Permit for 6-foot-tall fencing and gates at 1333 Lowrie Avenue in the Mixed Industrial High (MIH) Zoning District, in accordance with SSFMC Chapters 20.100 and 20.300, based on public testimony and materials submitted to the South San Francisco Planning Division which include, but are not limited to: Application materials prepared by applicant, submitted November 1, 2024; project plans prepared by EHDD Architecture, dated October 23, 2024; Zoning Administrator staff report dated December 19, 2024; and Zoning Administrator meeting of December 19, 2024. REQUIRED FINDINGS A. The proposed use is allowed within the applicable zoning district and complies with all other applicable provisions of this Ordinance and all other titles of the South San Francisco Municipal Code. Supportive Evidence: The project is located within the Mixed Industrial High (MIH) Zoning District and fences taller than four feet within the required front setback are allowed with Minor Use Permit approval; B. The proposed use is consistent with the General Plan and any applicable specific plan. Supportive Evidence: The proposed use is consistent with the General Plan which designates the site as Mixed Industrial High in the Lindenville sub-area and the project is compatible with the vision of the land use; C. The proposed use will not be adverse to the public health, safety, or general welfare of the community, nor detrimental to surrounding properties or improvements. Supportive Evidence: The project will not adversely impact to the public health, safety, or general welfare of the community, or detrimental to surrounding properties or improvements; D. The proposed use complies with any design or development standards applicable to the zoning district or the use in question as may be adopted by a resolution of the Planning Commission and/or the City Council. Supportive Evidence: The project complies with all other design or development standards applicable to the zoning district and use; E. The design, location, size, and operating characteristics of the proposed activity would be compatible with the existing and reasonably foreseeable future land uses in the vicinity. Supportive Evidence: 7 Conditions of Approval The design, location, size, and operating characteristics of the proposed activity would be compatible with the existing land uses in the vicinity and the proposed picket fence (transparent) meets the fence material requirement; F. The site is physically suitable for the type, density, and intensity of use being proposed, including access, utilities, and the absence of physical constraints. Supportive Evidence: The site is physically suitable for the type, density, and intensity of use being proposed, including access, utilities, and the absence of physical constraints; and G. An environmental determination has been prepared in accordance with the California Environmental Quality Act. Supportive Evidence: Staff has determined that the proposed project is Categorically Exempt pursuant to the provisions of California Environmental Quality Act Guidelines, Class 1, Section 15301, Existing Facilities. 8 CONDITIONS OF APPROVAL P24-0117: MUP24-0002 1333 LOWRIE AVENUE (As recommended by City Planning Staff on December 19, 2024) A. Planning Division requirements shall be as follows: 1. The applicant shall comply with the City of South San Francisco, Department of Economic and Community Development – Planning Division, standard Conditions and Limitations for Commercial, Industrial and Multi-Family Residential Projects. 2. The project shall be constructed and operated substantially as indicated on the plan set prepared by EHDD Architecture, dated October 23, 2024, and approved by the Zoning Administrator in association with MUP24-0002 as amended by the Conditions of Approval. The final plans shall be subject to the review and approval of the Chief Planner. 3. Applicant shall submit a checklist showing compliance with Conditions of Approval when applying building permit and business license applications. 4. The applicant shall maintain the existing landscaped area in compliance with Chapter 20.300.008 of the Zoning Ordinance. 5. All parking areas shall be maintained clear of litter and storage at all the time. No outdoor storage of materials is allowed, and no work shall be conducted outside of a building. 6. All exterior light sources, including canopy, perimeter, and flood, shall be energy-efficient, stationary, and shielded or recessed within the roof canopy to ensure that all light is directed away from adjacent properties and public rights-of-way. Lighting shall not be of a high intensity so as to cause a traffic hazard, be used as an advertising element, or adversely affect adjacent properties. 7. Applicant shall comply with all permitting requirements of Building Division related to the project and provide proof of permits and/or approval prior to building permit issuance for these project elements. 8. Demolition of any existing structures on site will require demolition permits. 9. The permit shall be subject to revocation if the project is not operated in compliance with the conditions of approval. (Planning Division contact person: Victoria Kim, Associate Planner (650) 877-8535) 9 B. Fire Department requirements shall be as follows: 1. Gates shall be set back not less than 20 feet from travel lanes on public right of ways. 2. Gates shall be automatic security gates as required by the fire code official in accordance with California Fire Code requirements. 3. Prior to approval of planning application, design documents for proposed fire service features, such as fire apparatus access road(s), access to building opening(s) and roof(s), premise identification, key boxes, fire protection water supplies, fire department connection location(s), and fire command center location(s) shall be submitted to the fire department for review and approval. a. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except where approved alternative methods of protection are provided. Temporary street signs shall be installed at each street intersection where construction of new roadways allows passage by vehicles. b. Construction documents for proposed fire apparatus access, location of fire lanes, security gates across fire apparatus access roads and construction documents and hydraulic calculations for fire hydrant systems shall be submitted to the fire department for review and approval prior to approval. 4. Projects shall be designed and constructed in compliance with established regulations as adopted by the City of South San Francisco affecting or related to structures, processes, premises, and safeguards in effect at the time of building permit application. 5. Fire service features for buildings, structures and premises shall comply with all City adopted building standards in effect at the time of building permit application. 6. Permit(s) shall be required as set forth in adopted California Building Code (CBC) Section 105 and California Fire Code (CFC) Sections 105.5 and 105.6. Submittal documents consisting of construction documents, statement of special inspection, geotechnical report, referenced documents, and other data shall be submitted electronically with each permit application. The construction documents shall be prepared by a registered design professional. Where special conditions exist, the code official is authorized to require additional construction documents to be prepared by a registered design professional. 7. Construction documents shall be to scale (graphic scale required on all plan sheets), dimensioned and drawn on suitable electronic media. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of adopted codes and relevant laws, ordinances, rules, and regulations, as determined by the fire code official. 10 8. Shop/construction drawings for the fire protection system(s) and other hazardous operations regulated by the fire department shall be submitted directly to the Fire Department to indicate conformance with adopted codes and standards. The construction documents shall be approved prior to the start of system installation. 9. The construction documents submitted with the application for permit shall be accompanied by a site plan showing to scale the size and location of new construction and existing structures on the site, distances from lot lines, the established street grades and the proposed finished grades and it shall be drawn in accordance with an accurate boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the location and size of existing structure and construction that are to remain on the site or plot. 10. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction. a. Prior to submitting building permits a fire department access and water supply for firefighting site plan shall be submitted for review and approval directly to the Fire Department. b. The plan shall indicate the location of fire department access doors and fire protection equipment, including standpipes, fire department connections and fire hydrants. 11. Prior to issuance of building permits, in accordance with CFC Section 105.6 the fire code official shall have the authority to require fire construction permit documents and calculations for all fire protection and life safety systems and to require permits be issued for the installation, rehabilitation or modification of any fire protection and life safety systems. Construction documents for fire protection and life safety systems shall be submitted for review and approval prior to system installation. Only the following fire construction permits are approved for deferred submittal: (1) Automatic fire extinguishing systems, (2) Emergency responder communication coverage system (ERCCS), and (3) Fire alarm and detection systems and related equipment. 12. Fire apparatus access roads shall be approved by the fire code official, installed and maintained in accordance with CFC Section 503 and Appendix D. a. Approved fire apparatus access roads shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the jurisdiction in accordance with adopted codes and standards at time of building permit application. i. Traffic calming measures (bollards, speed cushions, humps, undulations, etc.) are required to be approved by the fire code official prior to installation. 11 ii. Should a security gate(s) be planned to serve the facility, they shall be approved by the fire code official prior to installation. b. Required Fire Department access roads shall be signed “No Parking – Fire Lane” per current Fire Department standards and California Vehicle Code (CVC) Section 22500. 13. The provisions of the adopted CFC shall specify where fire protection and life safety systems are required and shall apply to the design, installation, inspection, operation, testing and maintenance of all fire protection systems. a. Approved automatic fire sprinkler systems in new buildings and structures, buildings changing use or occupancy, or as otherwise determined by the fire code official shall be provided in the locations described in adopted CFC Sections 903.2.1 through 903.2.20. i. Fire Department Connection (FDC) for the sprinkler and/or standpipe systems shall be located on the street side of the structure or facing approved fire apparatus access roadway fully visible and recognizable from the street, and within 100 feet an approved fire hydrant. ii. An approved, specifically engineered automatic sprinkler system shall be provided in buildings where EV charging, EV Ready or EV Capable vehicle parking are proposed. The remainder areas in the building shall comply with design requirements under NFPA 13 and in accordance with CFC. 14. Prior to issuance of any building or construction permits for the construction of public improvements, the final design for all public improvements shall be reviewed and approved by the City Engineer, Fire Marshal, and Chief Planner. 15. The following are a list of submittal items that are required by the Fire Department prior to approval of this planning application and shall be submitted directly to the Fire Department, additional items may be called out based on subsequent reviews: a. Fire apparatus access site plan and fire protection water supply 16. Please submit a complete electronic set of revised plans and the supporting documents, along with any redlined plans/documents included with this correction list to the South San Francisco Building Division. You must also submit in writing your responses to all review comments, inclusive of the sheet or detail number where your responses are located on the plans. (Fire Department contact person: Ian Hardage, Battalion Chief Fire Marshal (650) 829-6645) 12 ADDRESS: 1333 LOWRIE AVENUE, SOUTH SAN FRANCISCO 94080 APN: 015115290 ZONING: MIH - MIXED INDUSTRIAL HIGH USE: WAREHOUSING, STORAGE, AND DISTRIBUTION (INDOOR WAREHOUSING AND STORAGE) APPLICABLE CODES (BASIS OF DESIGN): CODE REQUIREMENTS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: APPLICABLE MUNICIPAL CODES SOUTH SAN FRANCISCO ZONING ORDINANCE APPLICABLE STATE CODES: 2022 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, CBSC 2022 CALIFORNIA BUILDING CODE (CBC), PART 2, CBSC 2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, CBSC 2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, CBSC 2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, CBSC 2022 CALIFORNIA ENERGY CODE (CPC), PART 6, CBSC 2022 CALIFORNIA FIRE CODE, PART 9, CBSC 2022 CALIFORNIA EXISTING BUILDING CODE, PART 10, CBSC 2022 CALIFORNIA REFERENCED STANDARDS, PART 12, CBSC TITLE 8 C.C.R., CH. 4, SUB-CH. 6-ELEVATOR SAFETY ORDERS TITLE 19 C.C.R., PUBLIC SAFETY, SFM REGULATIONS APPLICABLE FEDERAL CODES & STANDARDS: 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN EXISTING PARKING SPACES: 32 ON SUBJECT PARCEL INCLUDING 2 ACCESSIBLE PARKING SPACES PROPOSED PARKING SPACES: 32 ON SUBJECT PARCEL INCLUDING 2 ACCESSIBLE PARKING SPACES (NO CHANGES) PROJECT DATA 1343/1345 LOWRIE AVE. 1341 LOWRIE AVE. 1347 LOWRIE AVE. 1349 LOWRIE AVE. LOWRIE AVE. AP N 0 1 5 1 1 5 2 9 0 AP N 0 1 5 1 1 5 4 5 0 RAILWAY TRACKS PROPOSED NEW 6' HIGH ALUMINUM PICKET FENCE 33 4 ' - 1 " 33 1 ' - 9 " 240' - 0" 20' - 0" SETBACK PER SSFZO TABLE 20.100.003 MUP-02 41 2 3 PROPOSED 36" WIDE PEDESTRIAN GATE PER REQUIREMENTS OF CBC 11B-404 AP N 0 1 5 1 1 5 0 5 0 AP N 0 1 5 1 1 5 2 9 0 AP N 0 1 5 1 1 5 4 5 0 AP N 0 1 5 1 1 5 4 6 0 13451 LOWRIE AVE. 1353 LOWRIE AVE. 24' - 0" 24 ' - 0 " (E) ACCESSIBLE PARKING SPACES PER REQUIREMENTS OF CBC 11B-502 PROPOSED 6' HIGH VEHICULAR SWING GATE (E) LOADING RAMP ROOF OF EXISTING WAREHOUSE BUILDING (E) PARKING AREA (E) TREE, TYP 1 EXISTING CONDITION PHOTO ON MUP-02 (E) WOOD FENCE EXTERIOR LIGHT POLE UNDER SEPARATE PERMIT (E) MONUMENT SIGN(E) MONUMENT SIGN THE SUBJECT PROPERTY CONTAINS A STORAGE WAREHOUSE WITH PARKING AND LOADING AREAS ALONG ITS LOWRIE AVENUE FRONTAGE. THE PROPOSED PROJECT CONSISTS OF THE INSTALLATION OF A NEW 6-FOOT-HIGH VERTICAL PICKET (TRANSPARENT) FENCE AND GATES ALONG THIS FRONTAGE, PORTIONS OF WHICH ARE WITHIN THE FRONT SETBACK OF THE PROPERTY. THE PROPOSED FENCE WILL ENCLOSE THE PARKING AREA AND FACILITY ENTRANCE, BUT NOT THE LOADING AREA. THIS MINOR USE PERMIT APPLICATION IS REQUIRED BY THE SOUTH SAN FRANCISCO ZONING ORDINANCE TABLE 20.300.006 TO ALLOW FOR A FENCE AND GATE EXCEEDING 4 FEET HEIGHT WITHIN THE FRONT STREET-FACING SETBACK. PROJECT DESCRIPTION ARCHITECTURAL SITE PLAN LEGEND (E) - EXISTING ADJACENT BUILDING PROPERTY LINE LIMIT OF WORK ACCESSIBLE BUILDING ENTRANCES ACCESSIBLE BUILDING EXITS ACCESSIBLE FEATURE ACCESSIBLE PATH OF TRAVEL PROJECT ADDRESS 1333 LOWRIE AVENUE SOUTH SAN FRANCISCO, CA 94080 Stamp Consultant Sheet Number Sheet Title EHDD Job Number Drawn by Scale Printing Date MINOR USE PERMIT SUBMITTAL 10.23.2024 PIER 1, BAY 2 THE EMBARCADERO SAN FRANCISCO, CA 94111 [email protected] +1 415-285-9193 Revisions and Description Date 1333 LOWRIE FENCE MINOR USE PERMIT 10 / 2 5 / 2 0 2 4 4 : 5 5 : 4 8 P M A u t o d e s k D o c s : / / 2 4 0 5 6 U O V O T e n an t I m p r o v e m e n t s / 2 4 0 5 6 - A - U O V O T I - B L D G S - R 2 4 . r v t As indicated MUP-01 COVER SHEET AND SITE PLAN Author 24056 VICINITY MAP SHEET INDEX 1333 Lowrie Avenue NEW FENCE INSTALLATION MINOR USE PERMIT SUBMITTAL SCALE:1" = 20'-0"MUP-01 1 SITE PLAN PROJECT LOCATION N MUP-01 COVER SHEET AND SITE PLAN MUP-02 ELEVATION AND EXISTING PHOTOS 13 CONCRETE WAREHOUSE BUILDING BEYOND ROLLUP METAL LOADING DOORSMAIN BUILDING ENTRANCE (E) WOOD FENCE PROPOSED NEW 6' HIGH ALUMINUM PICKET FENCE PROPOSED 6' HIGH VEHICULAR SWING GATE PROPOSED 36" WIDE PEDESTRIAN GATE PER REQUIREMENTS OF CBC 11B-404 PROJECT ADDRESS 1333 LOWRIE AVENUE SOUTH SAN FRANCISCO, CA 94080 Stamp Consultant Sheet Number Sheet Title EHDD Job Number Drawn by Scale Printing Date MINOR USE PERMIT SUBMITTAL 10.23.2024 PIER 1, BAY 2 THE EMBARCADERO SAN FRANCISCO, CA 94111 [email protected] +1 415-285-9193 Revisions and Description Date 1333 LOWRIE FENCE MINOR USE PERMIT 10 / 2 5 / 2 0 2 4 4 : 5 2 : 3 6 P M A u t o d e s k D o c s : / / 2 4 0 5 6 U O V O T e n an t I m p r o v e m e n t s / 2 4 0 5 6 - A - U O V O T I - B L D G S - R 2 4 . r v t 1/8" = 1'-0" MUP-02 ELEVATION AND EXISTING PHOTOS Author 24056 EXISTING SITE PHOTO1 EXISTING SITE PHOTO2 EXISTING SITE PHOTO3 SCALE:1/8" = 1'-0"MUP-02 4 EAST ELEVATION 14 City of South San Francisco Legislation Text P.O. Box 711 (City Hall, 400 Grand Avenue) South San Francisco, CA File #:24-1203 Agenda Date:12/19/2024 Version:1 Item #:2 Report regarding consideration of a Minor Use Permit to allow handicraft/custom manufacturing and clean technology uses at 619 Airport Boulevard and 111 Pine Avenue in the T3 Corridor (T3C)Zoning District in accordance with Title 20 of the South San Francisco Municipal Code,and determination that the project is categorically exempt from CEQA. (Stephanie Skangos, Senior Planner) RECOMMENDATION Staff recommends that the Zoning Administrator conduct a public hearing and take the following actions: 1.Determine that the Project is categorically exempt under the provision of CEQA,Class 1,Section 15301, Existing Facilities; and 2.Approve the Minor Use Permit (MUP23-0005)based on the attached Draft Findings and subject to the attached Draft Conditions of Approval. BACKGROUND/DISCUSSION The applicant,Mytra,submitted an application for a Minor Use Permit (MUP)to operate their business,which includes office,engineering,light mechanical assembly,and product testing at 619 Airport Boulevard on November 20,2023. During review of the application,it was discovered that Mytra was currently operating at the project site’s other suite,111 Pine Avenue,and the application was updated to include both locations.Additionally,the application has also been updated, per the property owner’s request, to include clean technology as an additional potential use at the project site. Site Overview The project site is located at 619 Airport Boulevard and 111 Pine Avenue and consists of two parcels.APN 012-176-010 is a corner and through-lot with frontages on Airport Boulevard and Cypress and Pine Avenues.There is an existing 13,249 square foot,one-story building with two suites on this parcel.619 Airport Boulevard is currently vacant but was most recently occupied by an automobile/vehicle service and repair use;111 Pine Avenue is existing office space for Mytra.APN 012-176-020 is a through lot with frontages on Airport Boulevard and Cypress Avenue and contains an existing surface parking lot for the existing building,with entry access off Airport Boulevard and an egress driveway onto Cypress Avenue at the rear.The existing parking lot is not currently striped.The project site is surrounded by an existing hotel to the north,residential buildings to the west,commercial uses to the south,and U.S.Highway 101 (US 101)to the east. Project Overview Mytra is requesting an MUP to operate a handicraft/custom manufacturing use in both suites at the project site.Mytra is a technology start-up,developing automation,advanced robotics,and software for material flow in warehouses,distribution centers,and factories.The company consists of approximately 50 employees,and operating hours will be Monday through Friday,8 a.m.to 5 p.m.,with delivery hours between 9 a.m.and 5 p.m.Daily operations will include software and hardware engineering,small electronics wiring and soldering,and general assembly of robots,primarily within the space at 619 Airport Boulevard.111 Pine Avenue will continue to operate as office space for Mytra with some minor manufacturing and assembly tasks.Minor exterior improvements are proposed,including repainting of a portion of the building,striping of the parking lot to meet required zoning requirements,and installation of new fencing and gates for the parking area. No interior work is proposed at this time. In addition to the handicraft/custom manufacturing use requested by Mytra,the property owners have also requested that City of South San Francisco Printed on 12/11/2024Page 1 of 3 powered by Legistar™15 File #:24-1203 Agenda Date:12/19/2024 Version:1 Item #:2 this MUP include the potential for operation of clean technology use by future tenants. ZONING CONSISTENCY Proposed Use The project site is located within the T3 Corridor (T3C)Zoning District.Per South San Francisco Municipal Code (SSFMC)Table 20.135.060.B.1 (Uses in the Transect Zoning Districts),handicraft/custom manufacturing and clean technology are permitted with the approval of an MUP.Handicraft/custom manufacturing is defined in the SSFMC as the manufacture of products to serve niche or specialty markets in facilities that may use innovative technology and do not generate excessive nuisances.Clean technology is defined as a facility for research and the design,development,and testing of technology that uses less material and/or energy,generates less waste,and causes less environmental damage than alternatives. Staff supports Mytra’s proposal to operate a handicraft/custom manufacturing use at the project site.Mytra is a technology start-up,developing automation,advanced robotics,and software for material flow in warehouses,distribution centers,and factories.Daily operations include software and hardware engineering,small electronics wiring and soldering,and general assembly of robots,and will not generate excessive nuisances.The proposed use complies with the applicable provisions of the T3C Zoning District,is compatible with the surrounding uses,and will not have an adverse effect to the public health, safety or general welfare of the community. Additionally,staff supports the potential for a future clean technology use at the project site,as this use also complies with the applicable provisions of the T3C Zoning District,is compatible with the surrounding uses,and will not have an adverse effect to the public health,safety or general welfare of the community.Any future proposed clean technology use at the project site will be required to submit a new business license application,during which time staff can review the proposed use and confirm that it complies with all requirements of the approved Minor Use Permit.A Condition of Approval has been included requiring documentation showing how the proposed business meets the use classification definition for either handicraft/custom manufacturing or clean technology during the business license process. Parking Requirements The project site is located within a Transit Station Area,as the site is located within a half-mile of the South San Francisco Caltrain Station and along a transit corridor with a fixed route bus service.Per SSFMC Section 20.330.004 (Required Parking Spaces),and in accordance with AB 2097,no off-street parking is required for any use located within a Transit Station Area.Therefore,the proposed change of use does not trigger any parking requirements.However,as part of the project,the existing surface parking lot on the site will be striped in accordance with SSFMC Section 20.330.010 (Parking Area Design and Development Standards).There will be a total of five parallel parking spaces with a one-way gated drive aisle, with ingress access off Airport Boulevard and egress onto Cypress Avenue. GENERAL PLAN CONSISTENCY The proposed project is consistent with the City’s General Plan,which designates the site as Low Density Mixed Use. This land use designation is intended for lower-scale,mixed-use blending residential,commercial,and retail uses.The MUP request meets the intent of the adopted General Plan designation as an area of mixed-use. ENVIRONMENTAL REVIEW The proposed project has been determined to be categorically exempt under the provisions of CEQA,Class 1,Section 15301,Existing Facilities.The project site is an existing developed property surrounded by existing commercial buildings.The proposal includes only minor exterior improvements,including repainting of a portion of the building, restriping of the parking lot to meet required zoning requirements,and installation of new fencing and gates for the parking area. No interior work is proposed at this time. CONCLUSION The proposed uses are conditionally permitted and comply with the applicable provisions of the City’s Municipal Code, General Plan,and Zoning Development Standards.Additionally,the proposed uses are compatible with the surrounding City of South San Francisco Printed on 12/11/2024Page 2 of 3 powered by Legistar™16 File #:24-1203 Agenda Date:12/19/2024 Version:1 Item #:2 General Plan,and Zoning Development Standards.Additionally,the proposed uses are compatible with the surrounding uses and will not have an adverse effect to the public health,safety,or general welfare of the community.As such,staff recommends that the Zoning Administrator determine that the project is categorically exempt under the provision of CEQA,Class 1,Section 15301,Existing Facilities and approve the Minor Use Permit (MUP23-0005)to allow the operation of a handicraft/custom manufacturing and/or clean technology use at 619 Airport Boulevard and 111 Pine Avenue, based on the attached draft Findings and draft Conditions of Approval. Attachments: 1.Draft Findings 2.Draft Conditions of Approval 3.Project Plans City of South San Francisco Printed on 12/11/2024Page 3 of 3 powered by Legistar™17 DRAFT FINDINGS OF APPROVAL P23-0126: MUP23-0005 619 AIRPORT BOULEVARD & 111 PINE AVENUE (As recommended by City Staff on December 19, 2024) As required by the Use Permit Procedures (SSFMC Chapter 20.490), the following findings are made in support of a Minor Use Permit to allow handicraft/custom manufacturing and clean technology uses at 619 Airport Boulevard and 111 Pine Avenue in the T3 Corridor (T3C) Zoning District, in accordance with Title 20 of the SSFMC, based on public testimony and materials submitted to the South San Francisco Zoning Administrator which include, but are not limited to: Application materials submitted November 20, 2023; project plans prepared by Folio Architects and dated stamp received November 5, 2024; Zoning Administrator staff report dated December 19, 2024; and Zoning Administrator hearing of December 19, 2024. 1. Minor Use Permit A. The proposed use is an allowed use within the T3 Corridor (T3C) Zoning District and complies with applicable standards and requirements of the South San Francisco Municipal Code Title 20 Zoning. Conditions of approval will ensure continued compliance with the City’s Zoning Ordinance requirements and development standards; B. The proposed use is consistent with the City’s General Plan in that the project site is designated Low Density Mixed Use, and handicraft/custom manufacturing and clean technology uses are permitted in this District with the approval of a Minor Use Permit; C. The proposed use will not be adverse to the public health, safety or general welfare of the community, or detrimental to surrounding properties or improvements. The project does not propose operations that create impacts to surrounding areas, and conditions of approval will ensure that the use complies with the approved plans and the regulations and standards set forth in the South San Francisco Municipal Code. D. The proposed use complies with design or development standards applicable to the T3C Zoning District. Conditions of approval will ensure continued compliance with the City’s Zoning Ordinance. E. The design, location, size, and operating characteristics of the proposed activity would be compatible with the existing and reasonably foreseeable future land uses in the vicinity because the proposed uses are in character with the surrounding mix of businesses and land uses in the project vicinity and occupies an existing building; 18 Findings of Approval Page 2 of 2 F. The site is physically suitable for the type, density, and intensity of use being proposed, including access, utilities, and the absence of physical constraints because the site is already developed, and the proposed uses will be utilizing the existing building, which is already connected to all utilities; and G. In accordance with the California Environmental Quality Act, staff has determined that the proposed project is Categorically Exempt pursuant to the provisions of Section 15301 – Class 1: Existing Facilities (CEQA Guidelines). The proposed uses will occupy an existing building and only minor exterior work is proposed. 19 DRAFT CONDITIONS OF APPROVAL P23-0126: MUP23-0005 619 Airport Boulevard & 111 Pine Avenue (As recommended by City Staff on December 19, 2024) PLANNING DIVISION CONDITIONS Introduction The term “applicant”, “developer”, “project owner” or “project sponsor” used hereinafter shall have the same meaning: the applicant for the 619 Airport Boulevard and 111 Pine Avenue project or the property / project owner if different from applicant. GENERAL 1. The project shall be constructed and operated substantially as indicated on the plan set prepared by Folio Architects, dated stamp received November 5, 2024, and approved by the Zoning Administrator in association with P23-0126, as amended by the conditions of approval. The final plans shall be subject to the review and approval of the City’s Chief Planner. 2. The construction drawings shall comply with the Zoning Administrator approved plans, as amended by these Conditions of Approval, including the plans prepared by Folio Architects, dated stamp received November 5, 2024. 3. The permit shall be subject to revocation if the project is not operated in compliance with the conditions of approval. 4. Neither the granting of this permit nor any conditions attached thereto shall authorize, require or permit anything contrary to, or in conflict with any ordinances specifically named therein. 5. The applicant shall obtain all required permits for the initiation and operation of the proposed use, including a City Business License. 6. A City Business License shall be required for any new tenant/occupant/business locating at this site prior to operation. 20 Conditions of Approval Page 2 of 9 7. For any new business license application, documentation showing how the proposed business meets the use classification definition for either handicraft/custom manufacturing or clean technology shall be required for review and approval by Planning. 8. Prior to construction, all required building permits shall be obtained from the City’s Building Division. 9. All conditions of the permit shall be completely fulfilled to the satisfaction of the affected City Departments and Planning and Building Divisions prior to occupancy of any building. 10. The applicant shall submit a checklist showing compliance with these Conditions of Approval with the building permit application and plans. 11. The applicant shall comply with all permitting requirements of applicable agencies related to the project and provide proof of permits and/or approval prior to building permit issuance for these project elements. 12. Any modification to the approved plans shall be subject to SSFMC Section 20.450.012 (“Modification”), whereby the Chief Planner may approve minor changes. All exterior design modifications, including any and all utilities, shall be presented to the Chief Planner for a determination. 13. Unless the use has commenced or related building permits have been issued within two (2) years of the date this permit is granted, this permit will automatically expire on that date, subject to any extensions provided under the Subdivision Map Act or other applicable law. A one-year permit extension may be granted in accordance with provisions of the SSFMC Chapter 20.450 (“Common Procedures”). 14. The permit shall not be effective for any purpose until the property owner or a duly authorized representative files a signed acceptance form, prior to the issuance of a building permit, stating that the property owner is aware of, and accepts, all of the conditions of the permit. DESIGN REVIEW / SITE PLANNING 15. All equipment (either roof, building, or ground-mounted) shall be screened from view through the use of integral architectural elements, such as enclosures or roof screens, and landscape screening or shall be incorporated inside the exterior building wall. Equipment enclosures and/or roof screens shall be painted to match the building. Prior to issuance of a building permit the applicant shall submit plans showing utility locations, stand-pipes, 21 Conditions of Approval Page 3 of 9 equipment enclosures, landscape screens, and/or roof screens for review and approval by the Chief Planner or designee. 16. All landscaping installed within the public right-of-way by the property owner shall be maintained by the property owner. 17. Permanent project signage is not included in project entitlements. Prior to installation of any project signage, the applicant shall submit an appropriate sign application per SSFMC Chapter 20.360 (“Signs”) for review and approval. BUILDING DIVISION CONDITIONS 1. Provide F-1 for occupancy classification per the 2022 California Building Code. 2. Project shall be designed in compliance with 2022 California Building Code 11B. For questions concerning Building Division COAs, please contact Erik Reitdorf at [email protected] or (650) 829-6669. ENGINEERING DIVISION CONDITIONS The following items must be included in the plans or are requirements of the Engineering Division and must be completed prior to the issuance of a permit: General Engineering Conditions 1. The Applicant shall coordinate with the Public Works Department to ensure any proposed repair to the sewer lateral, sidewalks, curb and/or gutter will be satisfactory to the City. In addition, the Applicant shall obtain an encroachment permit for any proposed work in the public right of way. The Applicant shall be responsible for all applicable fees, deposits, and costs related to the proposed work. 2. As this proposed project results in a remodeling, alteration, or enlargement of greater than 25% of the building area (square footage), the Applicant shall meet all associated City Municipal Code requirements related to the sewer lateral including, though not necessarily limited to, the following: a. The Applicant shall call the Public Works Inspector at 650-829-6656 for instructions on performing CCTV and locating of the sewer lateral from the 22 Conditions of Approval Page 4 of 9 building foundation to the public sewer main. Video from this inspection shall be provided to the City for review as instructed. b. If a City-approved sewer cleanout is present in the sidewalk, the Applicant shall repair or replace damaged portions of the sewer lateral between the building foundation and the upstream end of the cleanout wye, as well the cleanout frame and cover, as directed by the Inspector. The Applicant is informed that in many cases, if pipe that connects to the upstream side of the wye is disturbed, the wye and cleanout assembly must also be replaced. This requirement also applies if there is no sidewalk, and the cleanout is no more than 3 feet behind the back of the curb line (if a curb is present), or no more than 3 feet behind the property line if there is no sidewalk, curb, or gutter. c. If no City-approved cleanout exists in the locations described above, the Applicant shall repair or replace damaged portions of the lateral between the building foundation and the sewer main, including the wye or break-in connection at the sewer main, as directed by the Inspector. Depending on the nature of the repairs, a second, post-repair video inspection of the lateral may be required, as determined by the inspector. The Applicant shall additionally install a new cleanout per City standards in the applicable location described above, and no closer than 5 feet away from the nearest driveway. Installation of a new sewer cleanout at the proper location will in most cases require installation of a new sewer lateral. d. The Applicant shall coordinate with the Inspector to ensure that any necessary sewer lateral repair or replacement work will be satisfactory to the City, shall obtain an encroachment permit for any work in the public right of way, backyard utility easement, or alley. All work related to these requirements shall be accomplished at the Applicant’s expense. e. Regardless of whether any sewer lateral work is required, the Applicant shall obtain a certificate of sewer lateral compliance from the City before the City will provide the first inspection of the new plumbing work, if plumbing work is included in the project. If no plumbing work is included in the project, the Applicant shall obtain the certificate of compliance before the first inspection of any work in the building. 3. Contractors must have a Class A license for any work in the street (beyond the face of curb). Contractors with a Class A license may perform any and all work associated with building permit requirements. For concrete work between the curb and the building, a Class C-8 license is sufficient. For plumbing work between the curb and the building, a Class C-36 license is sufficient. An exemption may be granted by the City if a relatively minor portion of the work 23 Conditions of Approval Page 5 of 9 is not covered by the Contractor’s license. For example, if a new sewer cleanout is being installed in the sidewalk by a Contractor with a C-36 (plumbing) license, the same Contractor may remove and reform no more than one (1) panel of the sidewalk without the need for a Class C-8 (concrete) license. 4. If excavation and grading work involves movement of more than 50 cubic yards of soil, a grading permit is required. The Applicant shall submit a grading plan that clearly states the amount of cut and fill required to grade the project. The grading plan shall clearly indicate existing and proposed elevations of all catch basins in the vicinity of the proposed project and all existing and proposed easements. Applicant is responsible for all associated fees and deposits. 5. Prior to the issuance of a grading permit if one is required, a geotechnical report shall be submitted, reviewed and approved by the Engineering Division. The Applicant shall place a $5,000 cash deposit with the City for the peer review of the Geotechnical Report. 6. Prior to receiving a grading or building permit, the Applicant shall submit a copy of their General Construction Activity Storm Water Permit Notice of Intent and Storm Water Pollution Prevention Plan (SWPPP) or wavier, where required by State or Federal regulations, to the Engineering Division for our information. 7. The Engineering Division reserves the right to include additional conditions during review of the building permit application. Special Engineering Conditions 8. All improvements shall be designed by a registered civil engineer and approved by the Engineering Division. 9. The Developer shall provide all existing and proposed elevations of the connection between the frontage road and the proposed driveway. These elevations include the pavement connection point, the proposed driveway centerline, top of curb, and bottom of curb. 10. The Developer shall provide tree protection to ensure existing trees are protected during the proposed development. 11. All new public improvements required to be constructed to accommodate the development shall be installed at no cost to the City and shall be approved by the City Engineer and constructed to City standards. The work shall be performed in accordance with an encroachment permit obtained by the developer from the Engineering Division, prior to the 24 Conditions of Approval Page 6 of 9 approval of the final map, or a subdivision improvement agreement approved by the City Council and shall be accomplished at no cost to the City. All new public improvements shall be completed within one year of obtaining a Building Permit for the proposed development, or prior to occupying structures at the site, whichever comes first. 12. The Applicant shall remove and replace any existing driveway that will no longer service garages or on-site driveways with City Standard sidewalk and curbs to the satisfaction of the City Engineer at no cost to the City. 13. Upon completion of the heavy construction and landscape work at the site, the Applicant shall clean, repair, or reconstruct, at their expense and as required to conform to City Standards, the existing public improvements including driveways, curbs, and sidewalks along the street frontages of the subdivision to the satisfaction of the City Engineer. Damage to adjacent property caused by the Applicant, or their contractors or subcontractors, shall be repaired to the satisfaction of the affected property owner and the City Engineer, at no cost to the City or to the property owner. 14. The Developer shall submit a sewer capacity study to determine how the project impacts the system and determine if there is adequate capacity of the sewer lines. The study shall include an analysis of all impacted sewer systems. Please be sure to include all supporting calculations. 15. The developer shall coordinate work with California Water Service for all water utility work. 16. All utility crossings shall be potholed, verified and shown on the plans prior to the building permit submittal. In addition, the Developer shall submit profiles of all proposed utilities 17. The Engineering Division reserves the right to include additional conditions during review of the building permit application. For questions concerning Engineering COAs, please contact Anthony Schaffer at [email protected]. FIRE DEPARTMENT CONDITIONS 1. Projects shall be designed in compliance with established regulations as adopted by the City of South San Francisco affecting or related to structures, processes, premises, and safeguards in effect at time of building permit application. 2. Fire service features for buildings, structures and premises shall comply with all City adopted codes and standards in effect at the time of building permit application. 25 Conditions of Approval Page 7 of 9 3. Permit(s) shall be required as set forth in adopted California Fire Code (CFC) Sections 105.5 and 105.6. Submittal documents consisting of construction documents, statement of special inspection, geotechnical report, referenced documents, and other data shall be submitted electronically with each permit application. The construction documents shall be prepared by a registered design professional. Where special conditions exist, the code official is authorized to require additional construction documents to be prepared by a registered design professional. 4. Construction documents shall be to scale (graphic scale required on all plan sheets), dimensioned and drawn on suitable electronic media. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of adopted codes and relevant laws, ordinances, rules, and regulations, as determined by the fire code official. 5. Construction/Shop drawings for the fire protection system(s) and other hazardous operations regulated by the fire department shall be submitted directly to the Fire Department to indicate conformance with adopted codes and standards. The construction documents shall be approved prior to the start of installation. 6. The construction documents submitted with the application for permit shall be accompanied by a site plan showing to scale the size and location of new construction and existing structures on the site, distances from lot lines, the established street grades and the proposed finished grades and it shall be drawn in accordance with an accurate boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the location and size of existing structures and construction that are to remain on the site or plot. 7. Prior to submittal of building permits, design documents for proposed fire service features, such as fire apparatus roads, fire protection water supplies, fire department connection locations, access to building openings and roofs, premise identification, key box locations, and fire command center locations shall be submitted to the Fire Department for review and approval. a) Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except where approved alternative methods of protection are provided. Temporary street signs shall be installed at each street intersection where construction of new roadways allows passage by vehicles. 26 Conditions of Approval Page 8 of 9 b) Construction documents for proposed fire apparatus access, location of fire lanes, security gates across fire apparatus access roads and construction documents and hydraulic calculations for fire hydrant systems shall be submitted to the fire department for review and approval prior to construction. 8. Prior to submittal of building permits, an approved water supply capable of supplying the required fire flow for fire protection shall be provided to premises on which facilities, buildings or portions of buildings are hereafter constructed or moved into or within the jurisdiction, in accordance with CFC Section 507, Appendices B & C. a) Fire-flow requirements for buildings or portions of buildings and facilities shall be determined by adopted CFC Appendix B and SSF Municipal Code. b) Fire hydrant systems shall comply with adopted CFC Section 507.5.1 through 507.5.8 and Appendix C. 9. Prior to issuance of building permits, the owner or owner’s authorized agent shall be responsible for the development, implementation, and maintenance of an approved written site safely plan approved by the fire code official in accordance with CBC & CFC Chapter 33. 10. Prior to issuance of building permits, in accordance with CFC Section 105.6 the fire code official shall have the authority to require fire construction permit documents and calculations for all fire protection and life safety systems and to require permits be issued for the installation, rehabilitation or modification of any fire protection and life safety systems. Construction documents for fire protection and life safety systems shall be submitted for review and approval prior to system installation. Only the following fire construction permits are approved for deferred submittal: (1) Automatic fire extinguishing systems, (2) Emergency responder communication coverage system (ERCCS), and (3) Fire alarm and detection systems and related equipment. 11. The proposed project is a change of use and occupancy of the existing building, and the project shall comply with building standards for the new use as currently adopted by the city. 12. The provisions of the adopted CFC shall specify where fire protection and life safety systems are required and shall apply to the design, installation, inspection, operation, testing and maintenance of all fire protection systems. 27 Conditions of Approval Page 9 of 9 a) An approved automatic fire sprinkler system shall be provided throughout the existing building to allow the new use and occupancy in accordance with adopted CFC Sections 903.2.1 through 903.2.20. i. Fire Department Connection (FDC) for the sprinkler and/or standpipe systems shall be located on the street side of the structure or facing approved fire apparatus access roadway fully visible and recognizable from the street, and within 100 feet an approved fire hydrant. 13. Prior to issuance of any building or construction permits for the construction of public improvements, the final design for all public improvements shall be reviewed and approved by the City Engineer, Fire Marshal, and Chief Planner. 14. The following are a list of submittal items that are required by the Fire Department and shall be submitted directly to the Fire Department, additional items may be called out based on subsequent reviews: a) Fire apparatus access site plan and fire protection water supply For questions concerning Fire Department COAs, please contact Ian Hardage at [email protected] or (650) 829-6645. PARKS DIVISION CONDITIONS 1. If any construction and/or public improvements are proposed along the Airport Boulevard frontage, the applicant shall be responsible for maintaining and/or removing the existing bulb-outs. For questions concerning Parks Division COAs, contact Joshua Richardson at [email protected]. 28 - - ELEVATION NO. THE TENANT, MYTRA, CURRENTLY OCCUPIES SUITE 111 PINE AVE., AND PLANS TO EXPAND INTO THE ADJACENT VACANT SUITE 619 AIRPORT BLVD. WITHIN THE SAME EXISTING 1-STORY BUILDING. THERE ARE NO PROPOSED BUILDING MODIFICATIONS AND THE TENANT WILL OCCUPY THE SPACE AS IS. THIS APPLICATION IS FOR A MINOR USE PERMIT TO ALLOW INDUSTRIAL/ R&D USES OF HANDICRAFT/ CUSTOM MANUFACTURING AND CLEAN TECHNOLOGY IN THE BUILDING. NEW FIRE PROTECTION TO BE INSTALLED PER FIRE DEPARTMENT'S DIRECTIONS. THE SCOPE OF EXTERIOR WORKS WILL INCLUDE: • RESTRIPE PARKING STALLS TO MEET MUNICIPAL DESIGN & DEVELOPMENT STANDARDS • (SCOPE REMOVED) • NEW SCREENING WALLS AND METAL GATES AT EXISTING PARKING LOT TO MEET MUNICIPAL DESIGN & DEVELOPMENT STANDARDS • NEW EXTERIOR SIGNAGE PAINTED ON BUILDING WALLS (DEFERRED SUBMITTAL) APPLICABLE CODES & ORDINANCES: 2022 EDITION CALIFORNIA BUILDING CODE (CBC) 2022 EDITION CALIFORNIA MECHANICAL CODE (CMC) 2022 EDITION CALIFORNIA PLUMBING CODE (CPC) 2022 EDITION CALIFORNIA ELECTRICAL CODE (CEC) 2022 EDITION CALIFORNIA ENERGY CODE 2022 EDITION CALIFORNIA FIRE CODE 2022 EDITION CALIFORNIA GREEN BUILDING STANDARDS CODE CITY OF SOUTH SAN FRANCISCO MUNICIPAL CODE (INCLUDING LOCAL AMENDMENTS TO THE ABOVE ADOPTED CODES AND LOCAL GREEN BUILDING REQUIREMENTS) TITLE 24, PART 6 , CALIFORNIA ENERGY CODE (LATEST EDITION) TITLE 24 HANDICAPPED ACCESSIBILITY REGULATIONS (LATEST EDITION) 408.980.8955 FOLIO ARCHITECTS ARCHITECT DEEPA DHAR [email protected] 4633 OLD IRONSIDES DRIVE, SUITE 360 SANTA CLARA, CA 95054 847.738.4716 MYTRA CLIENT CHRISTOPHER LARA [email protected] 111 PINE AVESOUTH SAN FRANCISCO, CA 94080 AREA OF WORK LOCATION MAP ABBREVIATIONS SYMBOLS WITH ABBREVIATIONS & AND @ AT CENTER ROUND SQUARE STANDARD ABBREVIATION ADMIN. ADMINISTRATION ALUM. ALUMINUM BD. BOARD BLDG. BUILDING D COMPRESSED AIR C/C CENTER TO CENTER CCA CLEAN COMP. AIR C.J CONSTRUCTION JOINT CLG. CEILING CLR. CLEAR C.M.U. CONCRETE MASONRY UNIT C02 CO2 CARBON DIOXIDE COL. COLUMN CONC. CONCRETE CONTIN. CONTINUOUS CONTIN. CW DOMESTIC COLD WATER DET. DETAIL D.F. DRINKING FOUNTAIN D.I. DEIONIZED WATER DIA. DIAMETER DIM. DIMENSION DN. DOWN DWG(S) DRAWING(S) DWR. DRAWER E. EAST (E) EXISTING EA. EACH E.D.R. EPOXY DRYING RACK EL. ELEVATION ELEC. ELECTRIC EQ. EQUAL EQUIP. EQUIPMENT E.S. EMERGENCY SHOWER E.W. EMERGENCY EYEWASH EXH. EXHAUST EXT. EXTERIOR F.D. FLOOR DRAIN F.E.C. FIRE EXTINGUISHER CABINET F.F. FINISHED FLOOR F.H. FUME HOOD FIN. FINISH FR. FIRE RISER F.O. FACE OF FINISHED OPENING F.O.C. FACE OF CONCRETE F.O.M. FACE OF MASONRY F.O.S. FACE OF STUD F.S. FLOOR SINK G. NATURAL GAS G.C. GENERAL CONTRACTOR GFRC GLASS FIBER REINFORCED CONCRETE GRD. GROUND GYP.BD.A. GYPSUM BOARD H.B. HOSE BIBB HC. HANDICAPPED HDW. HARDWARE HW DOMESTIC HOT WATER H.M. HOLLOW METAL HORIZ. HORIZONTAL HT. HEIGHT W.H. WATER HEATER INSUL. INSULATION INT. INTERIOR JAN. JANITOR LAB. LABORATORY LH LAMINAR FLOW HOOD LAM. LAMINATED LAV. LAVATORY MACH. MACHINE MAINT. MAINTENANCE MAX. MAXIMUM MECH. MECHANICAL MFR. MANUFACTURER MIN. MINIMUM M.R. MOISTURE RESISTANT MTL. METAL (N) NEW N NITROGEN GAS N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE O.C. ON CENTER OFF. OFFICE OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED P.L. PROPERTY LINE PLAM. PLASTIC LAMINATE PLBG. PLUMBING PLYWD. PLYWOOD P.T.D. PAPER TOWEL DISPENSER R. RADIUS R.A. RETURN AIR RCP REFLECTED CEILING PLAN R.D. ROOF DRAIN RES. RESILIENT RM. ROOM S STEAM S.A. SUPPLY AIR SECT. SECTION SHT SHEET SHWR. SHOWER SPEC. SPECIFICATION(S) SQ. SQUARE S.S. STAINLESS STEEL STD. STANDARD STOR. STORAGE STRUCT. STRUCTURAL SUSP. SUSPENDED TEL. TELEPHONE T.O. TOP OF (SPECIFY) T.O.W. TOP OF WALL TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE VAC. LAB VACUUM V.C.T. VINYL COMPOSITE TILE V.I.F. VERIFY IN FIELD W. WEST, WIDE W/ WITH W/O WITHOUT WD. WOOD W.R. WATER RESISTANT W.P. WATER PROOF CODE COMPLIANCE: 1. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE LATEST EDITION AND THE LATEST EDITIONS OF ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. ALL WORK TO COMPLY WITH THE STATE OF CALIFORNIA TITLE 24 ACCESSIBILITY REQUIREMENTS. OWNER & ARCHITECT INFORMATION: 2. THE TERM 'OWNER', AS NOTED ON DRAWINGS AND AS SPECIFIED HEREIN, REFERS TO MYTRA, 111 PINE AVE., SOUTH SAN FRANCISCO, CA 94080. 3. THE TERM 'ARCHITECT', AS NOTED ON DRAWINGS, REFERS TO FOLIO ARCHITECTS, 4633 OLD IRONSIDES DRIVE, SUITE 360, SANTA CLARA, CA 95054. SITE VISIT & SITE CONDITION: 4. THE GENERAL CONTRACTOR SHALL EXAMINE AND VERIFY EXISTING CONDITIONS AND DIMENSIONS. NO ADDITIONAL EXPENSE SHALL BE ALLOWED WHICH RESULTS FROM A FAILURE TO PERFORM THIS EXAMINATION. 5. THE GENERAL CONTRACTOR SHALL PROMPTLY REPORT ALL DISCREPANCIES, ERRORS AND OMISSIONS TO THE ARCHITECT, PRIOR TO STARTING THE AFFECTED WORK. 6. THE GENERAL CONTRACTOR SHALL SUBMIT TO THE OWNER, FOR APPROVAL, A DETAILED CONSTRUCTION SCHEDULE SHOWING PHASING OF WORK AND ANY MECHANICAL OR ELECTRICAL DISRUPTIONS TO BUILDING SERVICES. 7. THE GENERAL CONTRACTOR SHALL PROTECT AREA AND NEW OR EXISTING MATERIALS AND FINISHES FROM DAMAGE, WHICH MAY OCCUR FROM CONSTRUCTION, DEMOLITION, DUST, WATER, ETC. AND SHALL PROVIDE AND MAINTAIN TEMPORARY PARTITIONS, CLOSURE WALLS, ETC. AS REQUIRED TO PROTECT THE PUBLIC DURING THE PERIOD OF CONSTRUCTION. DAMAGE TO NEW AND EXISTING MATERIALS, STRUCTURE AND EQUIPMENT SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER AT THE EXPENSE OF THE GENERAL CONTRACTOR. 8. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LEAVING ALL AREAS IN A CLEAN CONDITION. 9. THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DOCUMENTS ON THE JOBSITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES AND SHALL PROVIDE ALL SUBCONTRACTORS WITH CURRENT CONSTRUCTION DOCUMENTS, AS REQUIRED. MATERIALS: 10. THE GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR FABRICATED ITEMS, CUT SHEETS OF ALL FIXTURES AND EQUIPMENT AND SAMPLES OF ALL FINISHES CALLED FOR TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION. 11. ALL MATERIALS, FIXTURES AND EQUIPMENT INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL BE NEW AND AS SPECIFIED, U.N.O. 12. MATERIALS ARE SPECIFIED BY THEIR BRAND NAMES TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE. ANY REQUEST FOR SUBSTITUTION SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW FOR EQUAL QUALITY AND PERFORMANCE AND SHALL NOT BE PURCHASED OR INSTALLED WITHOUT THEIR WRITTEN APPROVAL. 13. ALL NEW FINISHED AND PATCHED SURFACES SHALL BE SMOOTH AND FREE OF ANY IMPERFECTIONS AND IN A PROPER CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS SHALL MATCH THE ADJACENT MATERIALS, CONSTRUCTION AND FINISH. 14. PROVIDE ALL REQUIRED BLOCKING, FURRING AND BACKING FOR ANY WALL MOUNTED FIXTURES, SHELVING AND ACCESSORIES. 15. ALL JOINTS AND PENETRATION AT EXTERIOR WALLS, CEILINGS AND ROOF ASSEMBLIES SHALL BE FULLY CAULKED AND SEALED. DRAWING DIMENSIONS: 16. DO NOT SCALE FROM THE DRAWINGS. WRITTEN DIMENSIONS SHALL ALWAYS TAKE PRECEDENCE. THE ARCHITECT MUST BE NOTIFIED OF ANY CONFLICTS IN DIMENSIONING. 17. DIMENSIONS INDICATED ON THE FLOOR PLANS ARE TO FACE OF STUD OR EDGE OF COUNTERTOP, U.N.O. DIMENSIONS FROM EXISTING WALLS AND BUILDING SHELL ARE FROM FACE OF CONCRETE OR FACE OF (E) WALL. 18. FINISH FLOOR LEVEL OF SUB-FLOOR IS THE DATUM POINT (±0'-0") FROM WHICH ALL OTHER DIMENSIONS ARE TAKEN. 19. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE LOCATED 3" FROM THE FACE OF FINISHED WALL TO FACE OF DOOR FRAME JAMB. ARCHITECT'S & ENGINEER'S APPROVAL: 20. THE GENERAL CONTRACTOR SHALL MARK ALL LOCATIONS OF WALL AND DOORS FOR REVIEW BY ARCHITECT, PRIOR TO INSTALLATION. 21. FINAL LOCATIONS OF ALL VISIBLE EQUIPMENT, MP COMPONENTS, FIXTURES. ETC. SHALL BE APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. 22. ALL PENETRATIONS THROUGH STRUCTURAL MEMBERS, CEILING ROOF AND FLOOR SLAB SHALL REQUIRE APPROVAL BY THE ARCHITECT & STRUCTURAL ENGINEER PRIOR TO PERFORMING THE WORK. 23. NO NEW EQUIPMENT, PIPING, CONDUITS OR OTHER ITEMS SHALL BE SUSPENDED FROM ROOF SUB-PURLINS. FIRE PROTECTION: 24. ADDITIONS, CORRECTIONS AND MODIFICATIONS TO AUTOMATIC FIRE SPRINKLER SYSTEM WILL COMPLY WITH NFPA#13, 2019 EDITION. 25. PROVIDE NEW AND MODIFY EXISTING FIRE SPRINKLER SYSTEMS AS REQUIRED PER SPECIFICATIONS OF LOCAL GOVERNING AGENCIES. FIRE SPRINKLER SUBCONTRACTOR SHALL SUBMIT DESIGN BUILD DRAWINGS TO LOCAL GOVERNING AGENCIES FOR APPROVAL. 26. PROVIDE A MINIMUM OF 2A-10BC CLASSIFICATION FIRE EXTINGUISHER WITHIN 75' TRAVEL DISTANCE FOR EACH 6,000 SF OR PORTION THEREOF ON EACH FLOOR. (NFPA10 2019 EDITION & CFC STANDARDS 906). 27. THE MAXIMUM FLAMESPREAD CLASSIFICATION OF FINISH MATERIALS USED ON INTERIOR WALLS AND CEILINGS MUST NOT EXCEED THE LIMITS SET FORTH IN C.B.C.TABLE 803.9 ACCESSIBILITY COMPLIANCE: 28. ALL WORK TO COMPLY WITH THE STATE OF CALIFORNIA TITLE 24 ACCESSIBILITY AND AMERICANS WITH DISABILITIES ACT. 29. ALL EXIT DOORS MUST BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. CONTRACT CLOSE OUT: 30. CONTRACT CLOSE OUT: A. EXECUTE FINAL CLEANING PRIOR TO FINAL INSPECTION. B. MAINTAIN ONE SET OF RECORD DOCUMENTS WITH ACTUAL REVISIONS TO THE WORK. RECORD DOCUMENTS TO INCLUDE CONSTRUCTION DRAWINGS, SPECIFICATIONS, ADDENDA AND CHANGE ORDERS. SUBMIT DOCUMENTS TO ARCHITECT WITH FINAL APPLICATION FOR PAYMENT. 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 GRAPHIC SYMBOLS - - EXTERIOR ELEVATION SHEET NO. ELEVATION NO. - INTERIOR ELEVATION SHEET NO. - - - - ELEVATION NO. - - SHEET NO. BUILDING SECTION SECT. NO. SHEET NO. REVISION NUMBER# ROOM NAME RM.NO. ROOM NAME ROOM NUMBER CONTROL POINT, DATUM - - DETAIL NO. SHEET NO. DETAIL SECTION CONCRETE PLASTER GYPSUM BOARD WOOD-FINISH PLYWOOD ACOUSTIC TILE GLASS MATERIAL SYMBOLS WOOD - BLOCKING WOOD - CONTINUOUS MEMBER RIGID INSULATION METAL EARTH STEEL MEMBERS PROJECT SITE BUILDING DATA: OCCUPANCY CLASSIFICATION: (CBC SECTION 304) B CONSTRUCTION TYPE: (CBC TABLE 602) TYPE V-B BUILDING AREA: 13,249 SF ZONING: T3C (T3 CORRIDOR) APN:012176010, 012176020 LOT SIZE:10,075 SF (012176010), 4,176 SF (012176020) EXISTING USE AT 619 AIRPORT BLVD.: AUTO/ SALES REPAIR EXISTING USE AT 111 PINE AVE.: OFFICE BUIDLING HEIGHT: (E) 1-STORY FIRE PROTECTION: (E) NOT EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM PROJECT DATA: AREA OF WORK AT 619 AIRPORT BLVD.: 0 SF OCCUPANCY TYPE: B PROPOSED USE AT 619 AIRPORT BLVD.: HANDICRAFT/ CUSTOM MANUFACTURING (PER SSF MUNICIPAL CODE TABLE 20.135.060 (B)(1)) PROPOSED USE AT 111 PINE AVE.: OFFICE AND HANDICRAFT/ CUSTOM MANUFACTURING PROJECT DESCRIPTION PROJECT DATA PROJECT DIRECTORY DRAWING INDEX CHANGE OF USE ARCHITECTURAL SYMBOLS GENERAL NOTES SUITE 619 AIRPORT BLVD. MYTRA IS A SOFTWARE AND ROBOTICS COMPANY FOUNDED IN 2022, DEVELOPING STORAGE SOLUTIONS AND MATERIAL FLOW AUTOMATION. COMPANY SIZE IS 40-50 EMPLOYEES. WEBSITE: https://mytra.ai/ FIRE NOTES: 1. PRIOR TO SUBMITTAL OF BUILDING PERMITS, THE FOLLOWING ITEMS SHALL BE SUBMITTED DIRECTLY TO THE FIRE DEPARTMENT FOR REVIEW AND APPROVAL: A. FIRE APPARATUS ACCESS SITE PLAN B. FIRE PROTECTION WATER SUPPLY 2. PRIOR TO ISSUANCE OF BUILDING PERMITS, THE OWNER OR OWNER'S AUTHORIZED AGENT SHALL BE RESPONSIBLE FOR THE DEVELOPMENT, IMPLEMENTATION, AND MAINTENANCE OF AN APPROVED WRITTEN SITE SAFETY PLAN APPROVED BY THE FIRE CODE OFFICIAL IN ACCORDANCE WITH CBC & CFC CHAPTER 33. 3. PRIOR TO ISSUANCE OF ANY BUILDING OR CONSTRUCTION PERMITS FOR THE CONSTRUCTION OF PUBLIC IMPROVEMENTS SHALL BE REVIEWED AND APPROVED BY THE CITY ENGINEER, FIRE MARSHAL, AND CHIEF PLANNER. DEFERRED SUBMITTALS: 1. SIGN PERMIT. 2. FIRE SPRINKLER SOUTH SAN FRANCISCO CALTRAIN STATION SUITE 111 PINE AVE. 3 4 5 6 721 C E 1.50.1 D B A 7.9 T-001 TITLE SHEET PROJECT DATA & GENERAL NOTES A-100 ADJACENT SITES A-101 DEMOLITION SITE PLAN A-102 PROPOSED SITE PLAN A-201 FIRST FLOOR DEMOLITION FLOOR PLAN A-202 MEZZANINE LEVEL DEMOLITION FLOOR PLAN A-211 FIRST FLOOR PROPOSED FLOOR PLAN A-212 MEZZANINE LEVEL PROPOSED FLOOR PLAN A-221 EXISTING EXTERIOR ELEVATIONS A-222 PROPOSED EXTERIOR ELEVATIONS A-231 PROPOSED POWER AND UTILITY PLAN A-311 PROPOSED REFLECTED CEILING PLAN f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 TITLE SHEET PROJECT DATA & GENERAL NOTES T-001 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 SUITE 619 AIRPORT BLVD SUITE 111 PINE AVE TRU E NORT H N APN #012176020 APN #012176010 NO IMPROVEMENTS WORK NEW PRPOSED USE: HANDICRAFT/ CUSTOM MANUFACTURING ONLY NO IMPROVEMENTS WORK NEW MODIFIED USE: OFFICE & HANDICRAFT/ CUSTOM MANUFACTURING CYPRESS AVE. AIRPORT BLVD. PINE AVE. 4 4 4 4 4 4 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 4 11/01/24 PLANNING RESPONSE 2 4 29 f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 ADJACENT SITES A-100 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 1 2 4 2 5 1 3 4 5 PROJECT BUILDING PROJECT BUILDING 3 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 30 3 4 5 6 721 C E 1.50.1 D B A 7.9 111 PINE AVE (E) SIDEWALK (E) SIDEWALK ADJACENT BUILDING 4 EV CHARGING EV CHARGING EV CHARGING AIRPOR T BLVD CYPRESS AVE (E ) 2 5 ' - 3 " (E) 10 PARKING SPACES (NOT COMPLIENT WITH SSFMC 20.330.010) REMOVE (E) PARKING STALL STRIPING, TYP. (E) RAMP, LANDSCAPE AREA AND SIDEWALK TO REMAIN 619 AIRPORT BLVD. (E) ROLL-UP DOOR PROPERTY LINE PROPERTY LINE PROPERTY LINE (E) ELEC. 321 5 6 7 8 9 10 A-221 1 A-221 3 PINE AVE A-221 2 A-2214 (E ) LANDSCAPE (E) UNAUTHORIZED VEHICLE SIGNAGE REMOVE (E) CHAIN-LINK FENCE & GATE APN #012176020 (E) UNAUTHORIZED VEHICLE SIGNAGE APN #012176010 NO IMPROVEMENTS WORK NO IMPROVEMENTS WORK (E) TRANS REMOVE (E) CHAIN-LINK FENCE & GATE NEW MODIFIED USE: OFFICE & HANDICRAFT/ CUSTOM MANUFACTURING NEW PROPOSED USE: HANDICRAFT/ CUSTOM MANUFACTURING ONLY EXISTING PARKING ANALYSIS: TOTAL BUILDING AREA = 13,249 S.F. • 111 PINE AVE.: 600 S.F. OFFICE AREA + 5,965 S.F. FOR HANDICRAFT/CUSTOM MANUFACTURING AREA • 619 AIRPORT BLVD.: 6,684 S.F. FOR HANDICRAFT/CUSTOM MANUFACTURING PARKING SPACES REQUIRED PER SOUTH SAN FRANCISCO MUNICIPAL CODE 20.330.004 (F): F. TRANSIT STATION AREAS. IN ACCORDANCE WITH AB 2097, NO OFF-STREET PARKING IS REQUIRED FOR ANY USE LOCATED WITH A TRANSIT STATION AREA. THE PROJECT SITE IS WITHIN ONE-HALF MILE OF SOUTH SAN FRANCISCO CALTRAIN STATION. TOTAL PARKING REQUIRED:= 0 EXISTING TOTAL PARKING (NOT COMPLIANT WITH SSFMC 20.330.010): = 10 EXISTING VAN ACCESSIBLE PARKING:= 0 (PER CBC 11B 208.4) EXISTING REGULAR ACCESSIBLE PARKING:= 0 (PER CBC 11B 208.2) SUITE 111 PINE AVE. ACCESSIBLE PATH OF TRAVEL LEGEND: PROPERTY LINE SUITE 619 AIRPORT BLVD. f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 DEMOLITION SITE PLAN A-101 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 T RUE NORTH N 1/8" = 1'-0"1 DEMOLITION SITE PLAN 1 2 11 8 7 4 3 1 2 3 4 5 5 7 7 8 9 10 9 10 11 4 4 4 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 4 11/01/24 PLANNING RESPONSE 2 4 4 31 SUITE 111 PINE AVE. 1. WALKWAYS & SIDEWALKS ALONG ACCESSIBLE ROUTES OF TRAVEL SHALL BE (1) CONTINUOUSLY ACCESSIBLE, (2) HAVE MAXIMUM 1/2" CHANGES IN ELEVATION, OR HAVE CURB RAMPS COMPLYING WITH CBC 1112A; (3) ARE MINIMUM 48" IN WIDTH, AND (4) WHERE NECESSARY TO CHANGE ELEVATION AT A SLOPE EXCEEDING 5% (I.E., 1:20) SHALL HAVE PEDESTRIAN RAMPS COMPLYING WITH CBC 1113A. CBC 1114A. 2. DETECTABLE WARNINGS AT NEW CURBS RAMPS/CONCRETE POURS AT WALKWAYS ADJACENT TO/CROSSING VEHICULAR PATH OF TRAVEL, SHALL BE CAST-IN-PLACE. BOLT-ON OR STICK-ON DETECTABLE WARNINGS ARE NOT PERMITTED. ALL DETECTABLE WARNINGS MUST HAVE A MINIMUM 5 YEAR WARRANTY. 3. ACCESSIBLE PATH OF TRAVEL SHALL HAVE MAX. 5% SLOPE IN DIRECTION OF TRAVEL AND 2% MAX. CROSS SLOPE. NOTE: LEGEND: ACCESSIBLE PATH OF TRAVEL PROPERTY LINE SUITE 619 AIRPORT BLVD. MINIMUM FINE $250 VAN ACCESSIBLE INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE OVER DARK BLUE BACKGROUND. MIN SIZE 70 SQ. INCHES. VAN ACCESSIBLE AT VAN ACCESSIBLE PARKING SPACE PE R C B C 1 1 B 5 0 2 . 6 80 " M I N . L O C A T E D @ A C C E S S I B L E R O U T E S 60 " M I N . A B O V E F I N I S H G R A D E LO C A T E D @ L A N D S C A P E A R E A UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT _________________ OR BY TELEPHONING _________________ LETTERING NOT LESS THAN 1" IN HEIGHT NOTE: BLANK SPACES SHALL BE FILLED IN WITH APPROPRIATE INFORMATION AS A PERMANENT PART OF THE SIGN SIGNAGE TO BE VISIBLE FROM EACH PARKING STALL, OR AT ENTRY TO THE PARKING LOT, WALL OR POST MOUNTED. 17" MIN. 22 " M I N . 3 4 5 6 721 C E 1.50.1 D B A 7.9 AIRPOR T BLVD ADJACENT BUILDING CYPRESS AVE PINE AVE 8' - 6 " (E) SIDEWALK (E) SIDEWALK (N) PARKING STRIPING, TYP. PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE (E ) 2 5 ' - 3 " A-222 1 111 PINE AVE 619 AIRPORT BLVD. A-222 2 20'-0"20'-0"20'-0"20'-0"20'-0" (N) PARKING STALL #1 8'-6" x 20'-0" NO IMPROVEMENTS WORK NEW MODIFIED USE: OFFICE & HANDICRAFT/ CUSTOM MANUFACTURING (N) UNAUTHORIZED VEHICLE SIGNAGE APN #012176020 APN #012176010 (E) FENCE (E) ELEC. (E) TRANS (1 2 ' - 0 " M I N . ) (N ) A I S L E 1 6 ' - 9 " V . I . F . (N) PARKING STALL #2 8'-6" x 20'-0" (N) PARKING STALL #3 8'-6" x 20'-0" (N) PARKING STALL #4 8'-6" x 20'-0" (N) PARKING STALL #5 8'-6" x 20'-0" (N) UNAUTHORIZED VEHICLE SIGNAGE NEW PROPOSED USE: HANDICRAFT/ CUSTOM MANUFACTURING ONLY NO IMPROVEMENTS WORK (E ) LANDSCAPE PROVIDE OPEN PARKING LOTS LIGHTING ONE TO TWO FOOT-CANDLES AT GROUND LEVEL WITH VANDAL- RESISTANT COVERS IN ACCORDANCE WITH SSFMC SECTION 20.330.010. PARKING LOT LIGHTING SHALL NOT BE DIRECTED ONTO REISDENTIAL USE AREAS OR ADJACENT PUBLIC RIGHTS-OF-WAY, CONSISTENT WITH SSFMC SECTION 20.300.010. (N) 6'-0" HIGH METAL FENCE(N) 3'-0" HIGH METAL FENCE 15'-5" 10'-0" 15'-5" 10'-0" A-2223 TOTAL BUILDING AREA = 13,249 S.F. • 111 PINE AVE.: 600 S.F. OFFICE AREA + 5,965 S.F. FOR HANDICRAFT/CUSTOM MANUFACTURING AREA • 619 AIRPORT BLVD.: 6,684 S.F. FOR HANDICRAFT/CUSTOM MANUFACTURING PARKING SPACES REQUIRED PER SOUTH SAN FRANCISCO MUNICIPAL CODE 20.330.004 (F): F. TRANSIT STATION AREAS. IN ACCORDANCE WITH AB 2097, NO OFF-STREET PARKING IS REQUIRED FOR ANY USE LOCATED WITH A TRANSIT STATION AREA. THE PROJECT SITE IS WITHIN ONE-HALF MILE OF SOUTH SAN FRANCISCO CAL TRAIN STATION. TOTAL PARKING REQUIRED: = 0 TOTAL PARKING PROVIDED (RESTRIPING ONLY): = 5 ACCESSIBLE PARKING REQUIRED: = 0 (PER CBC 11B-202.4 EXCEPTIONS 5) VAN ACESSIBLE PARKING REQUIRED: = 0 (PER CBC 11B-202.4 EXCEPTIONS 5) CBC 11B-202.4 EXCEPTIONS 5: ALTERATIONS OF EXISTING PARKING LOTS BY RESURFACING AND/OR RESTRIPING SHALL BE LIMITED TO THE ACTUAL SCOPE OF WORK OF THE PROJECT AND SHALL NOT REQUIRE TO COMPLY WITH SECTION 11B-202.4. ACCESSIBLE PARKING PROVIDED = 0 (EXISTING SITE TECHNICAL INFEASIBILITY) SHORT TERM BICYCLE PARKING REQUIRED: (PER SSFMC 20.330.007 (A)) 5% X 0 = 0 LONG TERM BICYCLE PARKING REQUIRED: (PER SSFMC 20.330.007 (B)) 5% X 0 = 0 LONG TERM BICYCLE PARKING PROVIDED: (SEE 1/A-211) = 3 PROPOSED PARKING ANALYSIS: f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 PROPOSED SITE PLAN A-102 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 NTS 3 ACCESSIBLE PARKING SIGN DETAIL 1" = 1'-0"4 UNAUTHORIZED VEHICLE SIGNAGE DETAIL. 1/8" = 1'-0"1 PROPOSED SITE PLAN TRU E NORT H N NOT USED 4 4 4 4 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 4 11/01/24 PLANNING RESPONSE 2 4 4 4 4 4 4 4 44 32 UP UP UP UP UP DEMOLITION PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED 3 4 5 6 721 C E 1.50.1 D B A 7.9 (E) STAIRS TO REMAIN (E) STAIRS TO (E) MEZZANINE (E) RESTROOMS TO REMAIN (E) LOADING DOCK TO REMAIN (E) LOWER LEVEL (E) HIGHER LEVEL SMALL CLOSET 5ELECTRICAL CLOSET 4 (E) DOOR CONNECTING SUITES TO REMAIN (E) STAIRS TO REMAIN UP (E) WALLS AND DOORS TO REMAIN (E) WALL TO REMAIN (E ) W A L L A B O V E (E ) W A L L A B O V E (E) WALL ABOVE OPEN ABOVE OPEN ABOVE OPEN ABOVE 20'-0"20'-0"20'-0"20'-0"20'-0"20'-0" 120'-0" (E) WALLS & DOORS TO REMAIN (E) SHELVING TO REMAIN (E) FLOORING TO REMAIN (E) PRIVACY BLINDS AT DOORS & WINDOWS TO REMAIN OFFICE 11 TESTING CONTAINER 12 STORAGE 2 CONFERENCE 107 ASSEMBLY CONTAINER 103 SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. (E) RAMP (E) RAMP(E) RAMP (E) RAMP 18 ' - 9 " 1 8 ' - 5 " 1 8 ' - 5 " 1 8 ' - 9 " 74 ' - 4 " (E) STAIRS (E) UNISEX RESTROOMS TO REMAIN SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. (E) ROLL-UP DOOR STORAGE 104 (E) LEVEL LANDING (E) RAMP (E) LOWER LEVEL(E) HIGHER LEVEL CUSTOMER AREA 111 OPEN OFFICE 108 PRODUCT ASSEMBLY AREA 102 LOADING AREA 101 (E) TRASH & RECYCLING AREA (E) PORTABLE FIRE EXTINGUISHER (E) MEZZANINE ABOVE (E) PORTABLE FIRE EXTINGUISHER (E) ELECTRICAL PANEL BREAKROOM 112 CONTAINER 106 CORRIDOR 105 1 ALL DEMOLITION TO BE DONE PER APPLICABLE CODES AND REGULATIONS. 2 VERIFICATION OF EXISTING FIELD CONDITIONS IS REQUIRED PRIOR TO DEMOLITION. CONTRACTOR IS TO COORDINATE WITH BUILDING OWNER TO IDENTIFY ITEMS (QUANTITY AND QUALITY) TO BE SAVED AND REUSED. NOTIFY ARCHITECT IMMEDIATELY IF FIELD CONDITIONS REVEAL ITEMS NOT SHOWN ON PRICING PLAN. 3 PROTECT FROM DAMAGE ALL MATERIALS NOT REQUIRED TO BE REMOVED OR DEMOLISHED. 4 MAINTAIN ALL BUILDING SERVICES, SECURITY, FIRE ALARM AND FIRE PROTECTION SYSTEMS IN WORKING ORDER AT ALL TIMES DURING CONSTRUCTION. 5 ALL ELECTRICAL AND DATA OUTLETS, SWITCHES OR THERMOSTATS IN DEMOLISHED WALLS TO BE REMOVED. THERMOSTATS TO BE RELOCATED AS REQUIRED BY NEW PARTITION LAYOUT. 6 REMOVE ONLY THE UTILITY LINES AND CONDUITS WHICH ARE NOT INTENDED TO REMAIN IN THE TENANT SPACE AND ONLY IF THEIR REMOVAL WILL NOT IMPEDE THE OPERATION OF OTHER PORTIONS OF THE BUILDING. 7 REMOVE PIPING AND CAP ALL UTILITIES WHERE FIXTURES (SINKS, ELECTRICAL OUTLETS, SWITCHES, ETC.) AND/OR PARTITIONS HAVE BEEN REMOVED. CAP ALL UTILITIES BEHIND NEW FINISHED SURFACES. 8 PATCH AND REPAIR ALL WALLS TO REMAIN, AS REQUIRED, WHEN AFFECTED BY DEMOLITION. 9 ALL ELECTRICAL PANELS LOCATED IN WALLS TO BE DEMOLISHED SHOULD BE RELOCATED. COORDINATE WITH ARCHITECT. 10 DUST AND DEBRIS MUST NOT BE ALLOWED TO ENTER THE SUPPLY/RETURN AIR SYSTEM OR ADJACENT SPACES. TAPE OFF ALL EQUIPMENT OR DUCT OPENINGS AND PROVIDE DUST PROOF BARRIERS WHERE REQUIRED DURING CONSTRUCTION AND REMOVE ONCE DUST IS NO LONGER BEING GENERATED. 11 DOORS & DOOR FRAMES TO BE REMOVED & SALVAGED FOR REUSE WHEREEVER POSSIBLE. 12 DEMO TO INCLUDE REMOVAL OF ALL MISC. FIXTURES IN AREA OF WORK. DEMOLITION NOTES f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 FIRST FLOOR DEMOLITION FLOOR PLAN A-201 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 1/8" = 1'-0"1 FIRST FLOOR DEMOLITION FLOOR PLAN TRUE NORTH N 4 44 4 4 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 4 11/01/24 PLANNING RESPONSE 2 33 UP 3 4 5 6 721 C E 1.50.1 D B A 7.9 DN OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW 20'-0"20'-0"20'-0"20'-0"20'-0"20'-0" 120'-0" (E) MEZZANINE 8 (E) FIRE RISER 9 (E) MEZZANINE TO REMAIN (E) PEG BOARD TO REMAIN SHIPPING CONTAINER BELOW OPEN TO BELOW 18 ' - 9 " 1 8 ' - 5 " 1 8 ' - 5 " 1 8 ' - 9 " 74 ' - 4 " SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. OPEN TO BELOW (E) GUARDRAIL TO REMAIN SHIPPING CONTAINER BELOW (E) GUARDRAIL TO REMAIN SHIPPING CONTAINER BELOW MEZZANINE OFFICE 118 MEZZANINE OPEN OFFICE 115 MEZZANINE OPEN OFFICE 116 (E) STAIRS DEMOLITION PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED 1/8" = 1'-0"1 MEZZANINE LEVEL DEMOLITION FLOOR PLAN 1 ALL DEMOLITION TO BE DONE PER APPLICABLE CODES AND REGULATIONS. 2 VERIFICATION OF EXISTING FIELD CONDITIONS IS REQUIRED PRIOR TO DEMOLITION. CONTRACTOR IS TO COORDINATE WITH BUILDING OWNER TO IDENTIFY ITEMS (QUANTITY AND QUALITY) TO BE SAVED AND REUSED. NOTIFY ARCHITECT IMMEDIATELY IF FIELD CONDITIONS REVEAL ITEMS NOT SHOWN ON PRICING PLAN. 3 PROTECT FROM DAMAGE ALL MATERIALS NOT REQUIRED TO BE REMOVED OR DEMOLISHED. 4 MAINTAIN ALL BUILDING SERVICES, SECURITY, FIRE ALARM AND FIRE PROTECTION SYSTEMS IN WORKING ORDER AT ALL TIMES DURING CONSTRUCTION. 5 ALL ELECTRICAL AND DATA OUTLETS, SWITCHES OR THERMOSTATS IN DEMOLISHED WALLS TO BE REMOVED. THERMOSTATS TO BE RELOCATED AS REQUIRED BY NEW PARTITION LAYOUT. 6 REMOVE ONLY THE UTILITY LINES AND CONDUITS WHICH ARE NOT INTENDED TO REMAIN IN THE TENANT SPACE AND ONLY IF THEIR REMOVAL WILL NOT IMPEDE THE OPERATION OF OTHER PORTIONS OF THE BUILDING. 7 REMOVE PIPING AND CAP ALL UTILITIES WHERE FIXTURES (SINKS, ELECTRICAL OUTLETS, SWITCHES, ETC.) AND/OR PARTITIONS HAVE BEEN REMOVED. CAP ALL UTILITIES BEHIND NEW FINISHED SURFACES. 8 PATCH AND REPAIR ALL WALLS TO REMAIN, AS REQUIRED, WHEN AFFECTED BY DEMOLITION. 9 ALL ELECTRICAL PANELS LOCATED IN WALLS TO BE DEMOLISHED SHOULD BE RELOCATED. COORDINATE WITH ARCHITECT. 10 DUST AND DEBRIS MUST NOT BE ALLOWED TO ENTER THE SUPPLY/RETURN AIR SYSTEM OR ADJACENT SPACES. TAPE OFF ALL EQUIPMENT OR DUCT OPENINGS AND PROVIDE DUST PROOF BARRIERS WHERE REQUIRED DURING CONSTRUCTION AND REMOVE ONCE DUST IS NO LONGER BEING GENERATED. 11 DOORS & DOOR FRAMES TO BE REMOVED & SALVAGED FOR REUSE WHEREEVER POSSIBLE. 12 DEMO TO INCLUDE REMOVAL OF ALL MISC. FIXTURES IN AREA OF WORK. DEMOLITION NOTES TRU E NORTH N f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 MEZZANINE LEVEL DEMOLITION FLOOR PLAN A-202 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 4 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 4 11/01/24 PLANNING RESPONSE 2 34 UP UP UP UP UP FLOOR PLAN LEGEND (E) NON RATED WALL 3 4 5 6 721 C E 1.50.1 D B A 7.9 (E) STAIRS TO (E) MEZZANINE (E) RESTROOMS TO REMAIN LOWER LEVEL (E) HIGHER LEVEL (E) DOOR CONNECTING SUITES +48" (E) STAIRS TO REMAIN (E) STAIRS TO REMAIN +3.5" (E ) W A L L A B O V E (E ) W A L L A B O V E (E) WALL ABOVE OPEN ABOVE OPEN ABOVE OPEN ABOVE UP 20'-0"20'-0"20'-0"20'-0"20'-0"20'-0" 120'-0" STORAGE 6 (E) LOADING DOCK 3 MANUFACTURING #2 2 MANUFACTURING #1 1 ELECTRICAL CLOSET 4 (E) WALLS AND DOORS TO REMAIN (SCOPE REMOVED) STORAGE 11 15" MIN15" MIN 15" MIN 15" MIN 4' - 0 " (N) (3) WALL- MOUNTED VERTICAL BIKE RACKS SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. 18 ' - 9 " 1 8 ' - 5 " 1 8 ' - 5 " 1 8 ' - 9 " 74 ' - 4 " (E) WALL TO REMAIN TESTING CONTAINER 12 STORAGE 2 CONFERENCE 107 ASSEMBLY CONTAINER 103 (E) RAMP (E) RAMP(E) RAMP (E) RAMP (E) STAIRS (E) UNISEX RESTROOMS TO REMAIN (E) ROLL-UP DOOR STORAGE 104 (E) LEVEL LANDING (E) RAMP (E) LOWER LEVEL(E) HIGHER LEVEL CUSTOMER AREA 111 OPEN OFFICE 108 PRODUCT ASSEMBLY AREA 102 LOADING AREA 101 (E) TRASH & RECYCLING AREA (E) PORTABLE FIRE EXTINGUISHER (E) MEZZANINE ABOVE (E) PORTABLE FIRE EXTINGUISHER (E) ELECTRICAL PANEL BREAKROOM 112 CONTAINER 106 CORRIDOR 105 1 PROVIDE BACKING FOR WALL MOUNTED EQUIPMENT & CABINETS. COORDINATE EXACT FURNITURE LOCATIONS & EQUIPMENT REQIUIREMENTS. 2 ALL COUNTERTOPS IN LABS ARE 30" DEEP & 36" A.F.F., U.N.O 3 MAXIMUM HEIGHT OF ALL CONTROLS (SWITCHES, THERMOSTATS ETC) SHALL BE 48" A.F.F. TO TOP OF BOX. 4 ALL NEW ELECTRICAL OUTLETS ARE AT +18" A.F.F. U.N.O. OUTLETS SHALL NOT BE INSTALLED BACK TO BACK. STAGGER MIN 6". PROVIDE OUTLET PADS @ ALL WALLS WITH ACOUSTIC INSULATION. 5 ALL ELECTRICAL OUTLETS SHALL BE CLEARLY LAMBLED WITH PANEL NUMBER & CIRCUIT ID NUMBER. 6 ALL WALLS, DOORS AND DOOR FRAMES SHALL BE PAINTED P-1 U.N.O. 7 IN AREAS WITH NO CEILING, EXPOSED STRUCTURE AND DUCTWORK SHALL BE PAINTED P-2, U.N.O. 8 ALL WALLS SHALL BE PAINTED FROM CORNERS TO CORNERS. f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 FIRST FLOOR PROPOSED FLOOR PLAN A-211 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 FLOOR PLAN NOTES TRUE NOR TH N 1/8" = 1'-0"1 FIRST FLOOR PROPOSED FLOOR PLAN 4 4 4 4 4 4 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 4 11/01/24 PLANNING RESPONSE 2 35 FLOOR PLAN LEGEND (E) NON RATED WALL 3 4 5 6 721 C E 1.50.1 D B A 7.9 OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW 20'-0"20'-0"20'-0"20'-0"20'-0"20'-0" 120'-0" (E) MEZZANINE 8 (E) FIRE RISER 9 DN (E) MEZZANINE TO REMAIN OPEN TO BELOW OPEN TO BELOW (E) GUARDRAIL TO REMAIN SHIPPING CONTAINER BELOW (E) GUARDRAIL TO REMAIN 18 ' - 9 " 1 8 ' - 5 " 1 8 ' - 5 " 1 8 ' - 9 " 74 ' - 4 " SHIPPING CONTAINER BELOW OPEN TO BELOW (E) GUARDRAIL TO REMAIN SHIPPING CONTAINER BELOW (E) STAIRS MEZZANINE OPEN OFFICE 115 MEZZANINE OPEN OFFICE 116 SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. SUITE 619 AIRPORT BLVD. SUITE 111 PINE AVE. 1 PROVIDE BACKING FOR WALL MOUNTED EQUIPMENT & CABINETS. COORDINATE EXACT FURNITURE LOCATIONS & EQUIPMENT REQIUIREMENTS. 2 ALL COUNTERTOPS IN LABS ARE 30" DEEP & 36" A.F.F., U.N.O 3 MAXIMUM HEIGHT OF ALL CONTROLS (SWITCHES, THERMOSTATS ETC) SHALL BE 48" A.F.F. TO TOP OF BOX. 4 ALL NEW ELECTRICAL OUTLETS ARE AT +18" A.F.F. U.N.O. OUTLETS SHALL NOT BE INSTALLED BACK TO BACK. STAGGER MIN 6". PROVIDE OUTLET PADS @ ALL WALLS WITH ACOUSTIC INSULATION. 5 ALL ELECTRICAL OUTLETS SHALL BE CLEARLY LAMBLED WITH PANEL NUMBER & CIRCUIT ID NUMBER. 6 ALL WALLS, DOORS AND DOOR FRAMES SHALL BE PAINTED P-1 U.N.O. 7 IN AREAS WITH NO CEILING, EXPOSED STRUCTURE AND DUCTWORK SHALL BE PAINTED P-2, U.N.O. 8 ALL WALLS SHALL BE PAINTED FROM CORNERS TO CORNERS. f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 MEZZANINE LEVEL PROPOSED FLOOR PLAN A-212 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 FLOOR PLAN NOTES 1/8" = 1'-0"1 MEZZANINE LEVEL PROPOSED FLOOR PLAN TRUE NORTH N 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 36 SITE GROUND 0" STRUCTURAL FRAMING 15' - 6" 34567 2 1 MEZZANINE 11' - 6" ROOF 26' - 2" ELEVATED AREA 3' - 0" 20'-0"20'-0"20'-4"20'-4"19'-4"20'-0" 3' - 0 " 8 ' - 6 " 4 ' - 0 " 1 0 ' - 8 " 120'-0" 26 ' - 2 " SITE GROUND 0" STRUCTURAL FRAMING 15' - 6" 3 4 5 6 721 MEZZANINE 11' - 6" ROOF 26' - 2" ELEVATED AREA 3' - 0" 26 ' - 2 " 20'-0"19'-4"20'-4"20'-4"20'-0"20'-0" 120'-0" 10 ' - 8 " 4' - 0 " 8' - 6 " 3' - 0 " (E) ROLL-UP DOOR SITE GROUND 0" STRUCTURAL FRAMING 15' - 6" CE MEZZANINE 11' - 6" ROOF 26' - 2" D B ELEVATED AREA 3' - 0" A 26 ' - 2 " 3' - 0 " 8 ' - 6 " 4 ' - 0 " 1 0 ' - 8 " 18'-9" 18'-5" 18'-5" 18'-9" 74'-4" (E) MAIN ENTRANCE (E) ROLL-UP DOOR (E) CHAIN-LINK FENCE & GATE SITE GROUND 0" STRUCTURAL FRAMING 15' - 6" C E MEZZANINE 11' - 6" ROOF 26' - 2" DB ELEVATED AREA 3' - 0" A 26 ' - 2 " 4' - 0 " 1 0 ' - 8 " 18'-9"18'-5"18'-5"18'-9" 74'-4" ADJACENT PROPERTY (E) CHAIN-LINK FENCE & GATE 3' - 0 " 8 ' - 6 " f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 EXISTING EXTERIOR ELEVATIONS A-221 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 1/8" = 1'-0"3 EXISTING SOUTH ELEVATION 1/8" = 1'-0"1 EXISTING NORTH ELEVATION 1/8" = 1'-0"2 EXISTING EAST ELEVATION 1/8" = 1'-0"4 EXISTING WEST ELEVATION 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 4 11/01/24 PLANNING RESPONSE 2 4 4 37 SITE GROUND 0" STRUCTURAL FRAMING 15' - 6" 3 4 5 6 721 MEZZANINE 11' - 6" ROOF 26' - 2" ELEVATED AREA 3' - 0" 20'-0"19'-4"20'-4"20'-4"20'-0"20'-0" 120'-0" 26 ' - 2 " 10 ' - 8 " 4' - 0 " 8' - 6 " 3' - 0 " (E) ROLL-UP DOOR SITE GROUND 0" STRUCTURAL FRAMING 15' - 6" CE MEZZANINE 11' - 6" ROOF 26' - 2" D B ELEVATED AREA 3' - 0" A 26 ' - 2 " 3' - 0 " 8 ' - 6 " 4 ' - 0 " 1 0 ' - 8 " 18'-9" 18'-5" 18'-5" 18'-9" 74'-4" (N) PAINTED COMPANY LOGO, COLOR YELLOW (E) MAIN ENTRANCE (E) ROLL-UP DOOR (N) 3'-0" HIGH METAL FENCE (E) FENCE SITE GROUND 0" STRUCTURAL FRAMING 15' - 6" C E MEZZANINE 11' - 6" ROOF 26' - 2" DB ELEVATED AREA 3' - 0" A 26 ' - 2 " 6' - 0 " 5 ' - 6 " 4 ' - 0 " 1 0 ' - 8 " 18'-9"18'-5"18'-5"18'-9" 74'-4" (N) 6'-0" HIGH METAL FENCE ADJACENT PROPERTY f o l i o architects STAMP KEYPLAN 4633 old ironsides drive, suite 360 santa clara, california 95054 tel. 408-980-8955 fax. 408-980-9437 Project No. Proj. Manager Scale Date AS NOTED Revisions SHEET TITLE SHEET NUMBER CHANGE OF USE 619 AIRPORT BLVD. 111 PINE AVE. #2318 NOV. 10, 2023 PROPOSED EXTERIOR ELEVATIONS A-222 DEEPA DHAR 619 AIRPORT BLVD. / 111 PINE AVE. SOUTH SAN FRANCISCO, CA 94080 (N) PAINTED COMPANY LOGO, COLOR WHITE 1/8" = 1'-0"1 PROPOSED NORTH ELEVATION 1/8" = 1'-0"2 PROPOSED EAST ELEVATION SIGN PERMIT TO BE DEFERRED SUBMITTAL 11/09/23 ISSUED FOR PLANNING REVIEW 1 01/22/24 OWNER REVISIONS 2 02/13/24 PLANNING RESPONSE 3 03/08/24 OWNER REVISIONS 4 11/01/24 PLANNING RESPONSE 2 44 1/8" = 1'-0"3 PROPOSED WEST ELEVATION 4 38