HomeMy WebLinkAboutReso 54-1999RESOLUTION NO. 54-99
CITY COUNCIL, CITY OF SOUTH SAN FRANCISCO
STATE OF CALIFORNIA
A RESOLUTION APPROVING PRECISE PLAN (PP-99-005) TO ALLOW THE
CONSTRUCTION OF A FULL-SERVICE HOTEL ON A VACANT SITE LOCATED
IN THE OYSTER POINT MARINA PARK IN THE EAST OF 101 AREA.
WHEREAS, Corporex Oyster Point, L.L.C. has submitted a request to the City of South San
Francisco for approval of a Precise Plan to allow the construction of the full-service hotel in the Oyster
Point Marina Specific Plan District.
WHEREAS, the City of South San Francisco Planning Commission held a duly noticed public
hearing on April 15, 1999; and
WHEREAS, the City of South San Francisco City Council held a duly noticed public hearing on
April 28, 1999; and
WHEREAS, as required by the Oyster Point Marina Specific Plan District (SSFMC Chapter
20.59.020 (f) and 20.59.080), the following findings are made in support of the request for approval of a
Precise Plan application to allow construction of a full-service hotel located on a vacant lot at the west end
of the Oyster Point Marina Specific Plan District, based on all evidence, materials and testimony in the
record which include, but are not limited to: the plans dated January 4, 1999, prepared by Archiplan
International, Ltd.; Mitigated Negative Declaration, MND-99-005; minutes of the Design Review Board
meeting held on March 15, 1999; the February 18, 1999 Planning Commission staff report and minutes;
and testimony received at the February 18, 199 and April 15, 1999, Planning Commission meetings:
a)
The proposed use will not be adverse to the public health, safety, or general welfare of the
community, nor unreasonably detrimental to surrounding properties and improvements.
Because all such impacts and potential impacts have been mitigated by project design,
project location or Conditions of Approval.
2)
Subject to the above described amendments, the proposed project is consistent with the
Oyster Point Marina Specific Plan District. Because all potential inconsistencies have been
mitigated by adoption of an amendment to the Zoning Ordinance or approval of Conditions
of Approval.
3)
Subject to the above described amendments, the development standards of the proposed
project are consistent with the development standards of the Oyster Point Marina Specific
Plan District in that the plans meet or exceed those development standards identified in
Chapter 20.59 of the Zoning Ordinance. Because all potential inconsistencies have been
mitigated by adoption of an amendment to the Zoning Ordinance or approval of Conditions
of Approval.
4)
Subject to the above described amendments, the proposed use is consistent with the General
Plan (East of 101 Area Plan). A full-service hotel is an acceptable use in the Coastal
Commercial area.
5)
The proposed project is consistent with the joint powers agreement since the purpose of the
agreement is to authorize and empower the San Mateo County Harbor District and the City
of South San Francisco to jointly develop and construct facilities at Oyster Point
Marina/Park.
6)
The project, as designed and conditioned, meets or exceeds the requirements of the City' s
Zoning Ordinance. A hotel use is permitted in the Oyster Point Marina Specific Plan
District subject to an approved precise plan.
7)
The project has received prior approval by the harbor district board on January 20, 1999 by
a vote of four (4) ayes and one (1) no.
WHEREAS, A Mitigated Negative Declaration has been prepared in accordance with the
provisions of CEQA.
NOW, THEREFORE, BE IT RESOLVED that the City of South San Francisco City Council:
Approve Precise Plan, PP-99-005 to allow the construction of a full-service hotel located
at the west end of the Oyster Point Marina Specific Plan District in the East of 101 Area
subject to the Conditions of Approval in Exhibit A.
I hereby certify that the foregoing resolution was adopted by the City Council of the City of South San
Francisco at the regular meeting held on the 28th day of April ,1999 by the following vote:
AYES: Councilmembers Joseph A. Fernekes, and Eugene R. Mullin, and
Hayor James L. Datzman
NOES: Councilman John R. Penna and Mayor Pro Tel Karyl Matsumoto
ABSTAIN:
ABSENT:
ffone
~one
6} City Clerk
A:\ccresol.pp.wpd
8.
9.
10.
11.
12.
Exhibit A
PROPOSED CONDITIONS OF APPROVAL
GP-99-005, ZA-99-005, PP-99-005, MND-99-005
(April 28, 1999)
Planning Division requirements shall be as follows:
The project shall be constructed substantially as indicated on the attached site plan, landscape
plan, and elevations dated January 4, 1999 by Archiplan International, Ltd., except as
otherwise modified by the following conditions.
The applicant shall comply with all the mitigation measures outlined in the Mitigated
Negative Declaration.
Prior to issuance of a building permit, a Solid Waste Assessment Test (SWAT) Report shall
be prepared for approval by the California Regional Water Quality Control Board.
The applicant shall follow the City of South San Francisco, Department of Economic and
Community Development, Planning Division, Standard Conditions and Limitations for
Commercial Industrial, and Multi-Family Residential Projects.
Prior to issuance of a building permit the applicant shall provide staff with a copy of an
approved permit from the Bay Conservation and Development Commission (BCDC).
Prior to issuance of a building permit the applicant shall provide evidence of compliance
with FAA requirements regarding construction within the FAR Part 77 conical zone.
The applicant shall submit a unified sign program subject to separate review.
Stays for each individual hotel guest shall be limited to a maximum of 29 consecutive days.
Long- or short- term storage of motor vehicles shall not be permitted on the site.
The hotel operator shall assign a trained Transportation Coordinator to develop and
implement a Transportation Demand Management program to minimize off-site traffic
impacts and promote and transit use to employees and guests. The hotel operator shall
cooprerate with the City and the Multi-City TSM Agency to coordinate any furore shuttle
service to the hotel.
Prior to issuance of a business license, the hotel operator shall prepare a Parking
Management Plan that shall be submitted to the Chief Planner and the Police Department for
approval.
The hotel shall provide hotel guest shuttle service to and from the South San Francisco
BART and Caltrain Stations, the San Francisco International Airport and other attraction
points. The shuttle service shall be restricted to hotel guests, special events guests and
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 2 of 16
employees so as to eliminate incidental use by other parties not associated with hotel
activities.
13.
Special events at the hotel shall be scheduled during off-peak traffic hours unless the hotel
operator can demonstrate that adequate off-site parking exists and that no overflow impacts
of the event will effect traffic operation on the surrounding public streets and/or adjacent
properties. Self parking may be temporarily eliminated when parking demands require valet
service for the entire garage.
14.
In the event that off-site overflow parking is needed for special events, the hotel operator
shall obtain written authorization from the off-site property owners for the use of any off-site
parking spaces. Said authorization shall be submitted for review by the Chief Planner and the
South San Francisco Police Department.
15.
Valet operated parking shall be provided as necessary to maintain adequate traffic cimulation
on- and off-site and at no time shall vehicle queuing be allowed to back up onto Marina
Boulevard.
16.
No automobile rental facility which includes storage of vehicles on this site shall be
permitted to operate from the hotel.
17.
"Park and Fly" type promotions, where guests not currently occupying a hotel room leave a
vehicle at the site for a period after their stay at the hotel, shall not be permitted.
18.
The parking garage shall be maintained free of any material which would prevent use of
approved parking spaces.
19.
The applicant shall secure a Business License Site Clearance certificate prior to commencing
business operations on the site.
20.
The applicant shall provide a color scheme for the entire facility that is subject to approval
of the Chief Planner. Building color shall be indicated on the plans submitted for a building
permit and color and material samples shall be submitted for review and approval by the
Chief Planner prior to issuance of a building permit.
21. All roof mounted equipment shall be screened to the satisfaction of the Chief Planner.
22.
Final landscape and irrigation plans shall be submitted to the Planning Division for approval
by the Chief Planner prior to issuance of a building permit and shall address the issue ofnon-
invasive plant species identified in the Environmental Impact Report.
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 3 of 16
23.
There shall be no outside storage of materials and equipment. All on-site storage shall be
within building structures or other enclosed areas approved by the Chief Planner.
24.
The applicant shall screen all mechanical equipment on the roof and in the driveway areas.
The materials and color of the screening shall be submitted to the Planning Division for
review and approval by the Chief Planner prior to issuance of a building permit.
Tentative Map Conditions of Approval.
25.
The Final Parcel Map shall be substantially consistent with either the Tentative Parcel Map
entitled "Tentative Parcel Map PM 98-~" dated March 30, 1998, prepared by Wilsey
Ham, Engineers & Surveying or revised to indictate the approved roadway right-of-way on
the south side of Oyster Point Boulevard, between Gull Drive and Marina Boulevard, as a
result of the Oyster Point Boulevard Widening Project.
26.
The Final Parcel Map shall comply with all applicable requirements of SSFMC Title 20
(Zoning Ordinance).
(Planning Division Contact Person: Michael Lappen, Consulting Planner (650) 877-8535)
Building Division requirements shall be as follows:
The design and construction of all site alterations shall comply with all applicable codes and
regulations in effect at the time of plan submittal and building permit issuance.
A separate building permit application shall be submitted for each independent structure
proposed on the site. Applications shall be accompanied by five (5) complete sets of
construction drawings to include:
a)
b)
c)
d)
e)
t)
g)
h)
i)
J)
k)
Architectural plans
Structural plans
Electrical plans
Plumbing plans
Mechanical plans
Fire sprinkler plans
Landscape/irrigation plans
Site/civil plans
Structural Calculations
Truss Calculations
Soils reports
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 4 of 16
1) Title-24 energy documentation
The occupancy classification, construction type and square footage of each building shall be
specified on the plans in addition to justification calculations for the allowable area of each
building.
Any demolition of existing structures will require a permit. Submittal shall include three (3)
copies of the site plan, asbestos certification and PG&E disconnect notices. Also, application
must be made to the Bay Area Air Quality Management District prior to obtaining the permit
and beginning work..
A large portion of the subject property appears to be located in an A1 flood zone which is
identified as an area of special flood hazard. South San Francisco Municipal Code Section
15.56.030 states:
"No new construction, or substantial improvements of a structure which would
require a building permit, pursuant to the applicable provisions of the Uniform
Building Code as adopted and modified in Chapter 15.08 of this code, shall take
place in an area of special flood hazard without full compliance with the terms of this
chapter and other applicable flood control requirements".
Prior to submittal of plans to the Building Division for plan review, the applicant
shall determine where the actual flood fringe boundary lines occur on the property.
The lines shall be incorporated onto site/topographical plan which shall be included
as part of the required plan information noted above.
6. Building pads must be elevated to a point at least one foot above 100 year flood levels.
With regard to any grading or site remediation, soils export, import and placement; provide
a detailed soils report prepared by a qualified engineer to address these procedures. In
particular the report should address the import and placement and compaction of soils at
future building pad locations and should be based on an assumed foundation design.
Additionally, the unique conditions associated with building over a deep land-fill site
must be specifically and thoroughly addressed. Methane and other gaseous
containment will need to be addressed as well. This information should be provided to
Building and Engineering Division for review and comments prior to any such activities
taking place. A grading permit may be required for the above mentioned work.
o
Prior to building permit issuance for the construction of each building, geotechnical and civil
pad certifications are to be submitted.
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 5 of 16
Fire sprinklers will be required throughout the building. Separate application by a C-16
contractor is required.
10. Smoke detection system, smoke control system, and fire alarm systems will be required.
11. Stand-by power for lighting and emergency systems will be required.
12. Water for landscape irrigation should be separately metered.
13.
All site signage as well as wall signs require a separate permit and application (excluding
address numbering).
14. The tentative address for this building is 500 Marina Boulevard.
15.
Monument sign(s) located at the driveway entrance(s) shall have address numbers posted
prominently on the monument sign.
16.
Each building shall have address numbers posted in a conspicuous place on the building.
Numbers should be minimum 10" in height and either internally or extemally illuminated.
17.
In the parking garage, unless the design qualifies as an "Open Parking Structure",
mechanical ventilation will be required capable of exhausting a minimum of 1.5 cubic feet
per minute per square foot of gross floor area. Automatic carbon monoxide-sensing devices
may be employed to modulate the ventilation system. Connecting offices waiting rooms,
restrooms, and retail areas shall be supplied with conditioned air under positive pressure.
18.
In the parking structure, and in other areas where motor vehicles are stored, floor surfaces
shall be of noncombustible, nonabsorbent materials. Floors shall drain to an approved oil
separator or trap discharging to sewers in accordance with the Plumbing Code and South San
Francisco Municipal ordinances.
19.
The site development of such items as common sidewalks, parking areas, stairs, ramps,
common facilities, etc are subject to compliance with the accessibility standards contained
in Title-24, California Code of Regulations. The civil, grading and landscape plans shall
address these requirements to the extent possible.
20.
All areas within the site must be handicap accessible. All newly constructed buildings on
a site shall have, but are not limited to, the following accessible features:
a)
b)
Path of travel from public transportation point of arrival
Routes of travel between buildings
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 6 of 16
c)
d)
e)
t)
g)
h)
i)
Accessible parking
Ramps
Primary entrances
Sanitary facilities (restrooms)
Drinking fountains & Public telephones (when provided)
Accessible features per specific occupancy requirements
Accessible special features, ie., ATM's point of sale machines, etc.
21.
Pedestrian access provisions should provide a minimum 48" wide unobstructed paved
surface to and along all accessible routes. Items such as signs, meter pedestals, light
standards, trash receptacles, etc., shall not encroach on this 4' minimum width. Also, note
that sidewalk slopes and side slopes shall not exceed published minimums per California
Title 24, Part 2.
22.
A path of entry from the public way to a primary entrance must be provided that will meet
the minimum requirements of the UBC and Title 24.
23.
Minimum elevator car size (interior dimension) is 68" wide and 51" deep, with a clear door
width of 36". Also, at least one elevator car per tower shall accommodate a stretcher, 80"
wide and 54" deep with a 42"wide door opening.
24.
Review and approval by the San Mateo County Health Department will be required prior to
submittal for building permit plan review.
25.
School fees will be required for the project. School fees for commercial projects are
computed at $0.15 per square foot of interior space. Residential construction is currently
computed at $1.50 per square foot of living area. Calculations are done by the SSFUSD and
those fees are paid directly to them prior to issuance of the building permit.
26.
Handicapped parking spaces must be provided according the following table and must be
uniformly distributed throughout the site.
Total Number of Parking Spaces
Provided
Minimum Required Number of H/C
Spaces
I to25 1
26 to 50 2
51 to75 3
76 to 100 4
101 to 150 5
151 to 200 6
201 to 300 7
301 to 400 8
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 7 of 16
401 to 500
501 to 1,000
1,001 and over
9
Two percent of total
Twenty, plus one for each 100 or
fraction thereof over 1,001
27.
At least one handicap parking space must be van accessible; 9 feet wide parking space and
8 feet wide off-load area. Additionally, one in every eight required handicap spaces must be
van accessible.
28.
All entrances to and vertical clearances within parking structure shall have a minimum
vertical clearance of 8 feet 2 inches where required for accessibility to accessible parking
spaces.
29.
At least one fully accessible guest room or suite shall be provided. Additional fully
accessible guest rooms shall be provided in accordance with the following table.
Total Number of Rooms Fully Accessible Rooms Required Plus Additional Accessible Rooms
with Roll-in Showers
1 to25 I 0
26 to 50 2 0
51 to75 3 1
76 to 100 4 1
101 to 150 5 2
151 to 200 6 2
201 to 300 7 3
301 to 400 8 4
401 to 500 9 4 Plus 1 for each
501 to 1,000 Two percent of total additional 100
1,001 and over Twenty, plus one for each 100 or over 400
fraction thereof over 1,000
30.
31.
Minimum shower size in the fully handicapped room is either 60" wide by 30" deep or 42"
wide by 48"deep.
In addition to the rooms provided per the table above, additional rooms shall be provided
with visual notification devices for the hearing impaired for smoke and fire alarm as well as
to alert room occupants of incoming telephone calls and door knocks. The number of
additional rooms shall be per the table below.
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 8 of 16
Total Number of Rooms
Additional Rooms to be Equipped for
Hearing Impaired
lto25 1
26 to 50 2
51 to 75 3
76 to 100 4
101 to 150 5
151 to 200 6
201 to 300 7
301 to 400 8
401 to 500 9
501 to 1,000 Two percent of total
1,001 and over Twenty, plus one for each 100 or
fraction thereof over 1,000
32. Building construction must be Type I construction throughout. Minimum 2 hour separation
is required between the parking garage and the hotel.
33. Fire lanes must be designated, painted and signed.
34. Evacuation placards must be installed in all rooms.
35. Knox box keyed entry system is required at designated access doors.
36. Minimum required clearance under port cochere for fire equipment is 13' 6".
37. The driveway shall meet City requirements for a 20' width and 34' a minimum inside radius
in order to ensure that there is adequate access for Fire fighting equipment.
38. Engineering design shall be based on 80 mph wind factor at exposure D.
39. This building meets the definition of a High Rise Building. As such, it is required to comply
with the State Fire Marshal's life safety requirements for High Rises.
(Building Division Contact Person: Thomas Ahrens, Assistant Building Official (650) 829-6670)
C. Engineering Division requirements shall be as follows:
The Engineering Division has reviewed the Tentative Parcel Map, Sheet 1 of 1, dated March 30,
1998, prepared by Wilsey & Ham Civil Engineers; the Architectural Site Plan, Sheet No. AS 1.00,
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 9 of 16
dated March 16, 1998, prepared by Archiplan International, Ltd.; and the Preliminary Engineering
Plan, Sheet No. 1 of 1, dated January 4, 1999, revised February 17, 1999, prepared by Marchris
Engineering, Ltd. We have also reviewed the Mitigated Negative Declaration, dated March 12,
1999, for the proposed project. These documents were submitted by the applicant, Corporex Oyster
Point, L.L.C., in connection with the subject Precise Plan and Tentative Map proposals for the Oyster
Point Hilton Hotel.
Should the Planning Commission and the City Council approve this project, we request that the
following items be included in the conditions of approval for Precise Plan No. 99-005 and Parcel
Map No. 99-005:
Precise Plan Conditions of Approval.
The developer shall comply with all conditions of the Engineering Division's "Standard
Conditions for Commercial and Industrial Developments" requirements contained in our
"Standard Conditions for Subdivision and Private Development" Booklet dated December
1997.
The applicant shall submit a copy of their General Construction Activity Storm Water Permit
Notice of Intent and Storm Water Pollution Prevention Plan (SWPPP) for this project, as
approved (or submitted to) the State Water Resources Control Board, prior to receiving a
grading or building permit for the hotel project.
In accordance with the Standard Conditions, the project developer shall construct and install,
along the entire Oyster Point Boulevard and Marina Boulevard frontages of their project: new
City Standard commercial driveway approaches, curb, gutter, sidewalk and street lighting,
to match and conform with the existing improvements along Oyster Point and Marina
Boulevards. All work shall be performed in accordance with plans approved by the City
Engineer and at no cost to the City.
In accordance with the project's Negative Declaration's Transportation/Traffic mitigation
measure No. 2: The applicant shall either reconfigure the proposed truck loading dock
accessing Gull Drive to accommodate more that one semi-trailer track at a time, to the
satisfaction of the Engineering and Police Departments, or relocate the truck loading dock
to another area of the site. Hotel delivery trucks shall not be permitted to use Gull Drive for
either queuing or undertaking backing movements to access the loading area.
The applicant shall revise the Hotel development to fit within the boundaries of the parcel
shown on the approved Tentative Parcel Map. (The property lines along the Oyster Point
Boulevard frontage of the site shown on the above referenced tentative map do not coincide
with the property lines shown on the development plans.)
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 10 of 16
In accordance with the project's Negative Declaration traffic mitigation requirements and the
Hilton Hotel Focused Traffic Analysis for the Oyster Point Marina, dated March 11, 1999,
prepared by CCS, Inc., the developer shall reimburse the City for 18 % of the entire cost to
design, furnish, construct, install and inspect a new signalized intersection at Marina and
Oyster Point Boulevards, consisting of a traffic signal, controller, appurtenances and an
interconnect with the Gull Road traffic signal. The amount of this reimbursement will be
determined by the Director of Public Works.
Tentative Map Conditions of Approval.
The applicant shall comply with the requirements of the Engineering Division's "Standard
Conditions for Tentative Parcel Maps" section of the "Standard Conditions for Subdivisions
and Private Developments" booklet dated December 1997.
In accordance with the Standard Conditions and the City's Master Fee Schedule, the
applicant shall pay the City's actual plan check and coordination costs for City staff services
and to retain a land surveyor to plan check the preliminary map and to sign the parcel map
as the City's Technical Reviewer.
Geotechnical, foundation and hazardous investigation reports prepared for development
within the subject parcel shall be noted on the Parcel Map.
10.
The parcel map shall contain a sheet showing the relationship and location of the subject
parcel to other parcels and to any remainder parcel within the Oyster Point Marina site.
11.
Prior to receiving a building permit for the Hotel, the existing "Roadway Easement" (1995
OR 227) crossing the project site shall be vacated by the easement "owner".
(Engineering Division Contact Person: Richard Harmon (650) 829-6650)
D. Police Department requirements shall be as follows:
Site Plan, Parking, and Circulation.
1. The applicant shall cut back the comer of the entry driveway from Marina Drive so vehicles
will not have to drift to the wrong side of the road in order to enter the property.
2. All handicapped, compact, loading/unloading, and delivery parking spaces shall be clearly
marked with pavement markings and appropriate signs.
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 11 of 16
o
11.
12.
13.
14.
Parking spaces that overhang a 6 foot wide landscape strip or sidewalk may be a minimum
of 16 feet in depth.
Circulation aisles and backup space shall be a minimum of 25 feet in width.
The applicant shall install directional signs, traffic control devices, and traffic circulation
markings where appropriate or required on site.
Parking lots, aisles, passageways, recesses, and grounds contiguous to buildings shall be
provided with high intensity discharge lighting with sufficient wattage to provide adequate
illumination for the safety and security of vehicles and pedestrians using the site during the
hours of darkness or diminished lighting. Such lighting shall be equipped with vandal-
resistant covers/lenses.
A lighting level of 1 to 2 footcandles minimum maintained at ground level is required in all
open vehicle and pedestrian areas. Covered parking areas shall be illuminated at a level of
5 footcandles minimum maintained at all hours.
All exterior doors shall be adequately illuminated at all hours with their own light source.
Exterior door, perimeter, canopy, and parking area lights shall be controlled by photocell and
shall remain on during the hours of darkness or diminished lighting.
The lighting required above shall be installed according to a lighting plan reviewed and
approved by the Police Department prior to issuance of a building permit. The lighting plan
shall include photometric and distribution data attesting to the required lighting levels. The
current submittal lacks sufficient detail in order to determine whether lighting shown is
acceptable for the site.
All entrances to the parking area shall be posted with appropriate signs per 22658(a) CVC,
to assist in removing vehicles at the property owner's/manager's request. For additional
details, contact the Traffic Bureau at 877-8948.
Space should be designated and clearly marked near the main entrance for hotel shuttle
parking and for hotel registration parking.
The perimeter landscaped areas shall incorporate security type plant materials to discourage
persons from cutting through the parking areas or trampling the vegetation or climbing
perimeter fences and walls.
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 12 of 16
15. The outside of the perimeter barrier shall be clearly posted with no trespassing signs.
16.
The perimeter of the site shall be fenced during construction and security lighting and
security guards shall be employed and deployed as necessary. A security person is
mandatory during nonconstruction hours.
17.
Prior to the issuance of building permits the applicant shall submit a plan that will include
the installation of curb, gutter sidewalk and roadway lighting improvements on Marina Drive
fronting the property. These improvements shall be in place before the commencement of
any construction activity on the site.
Security and Safety Plan Information
18.
The applicant shall provide the Police Department with documented safety/security plan for
the project detailing systems that the applicant intends on installing to protect patrons,
visitors, employees, and company property/assets on site. The Police Department shall
review and approve the plans prior to issuance of a building permit. The plan shall detail
issues such as safes to be installed, room rekeying systems, deployment of security personnel,
safe deposit boxes, etc.
Use Conditions
19.
The applicant shall discourage and control the renting of hotel sleeping units to persons
(especially minors) for the purpose of hosting parties on site. The applicant shall
immediately deal with problems that result from such activity and shall provide adequate
security and supervision so unruly gatherings do not become a burden on police services.
Special Security Measures
20.
Prior to issuance of a building permit, the following areas shall be addressed to the
satisfaction of the Police Department Crime Prevention Unit:
Alarms
21.
Storage rooms, including the linen storage rooms, laundry rooms, food and liquor storage,
pantry, roof access doors, maintenance, mechanical, electrical, and other room doors which
contain property that may be susceptible to theft, shall be covered by a silent intrusion alarm
system. These systems may terminate at the front desk.
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 13 of 16
22.
The business shall be equipped with a central station silent robbery alarm system. Alarm
buttons or other activation devices shall be placed at the front desk, in the administration
office, and in any other locations deemed appropriate by management.
NOTE:To avoid delays in occupancy, alarm installation steps should be taken well in advance of the
final inspection.
Misc. Special Security Measures
23.
A time delay drop-safe type system is required near the registration desk area to provide the
on-duty clerks with the ability to limit available cash on hand. Any safe on site will have a
minimum rating ofTL-15 or class 'C' and should be equipped with a duress alarm capability.
24.
One or more closed circuit television cameras shall be employed to monitor the front desk
and lobby areas, any building access doors not monitored by the reception desk and all
covered parking areas in case of robbery or other serious felony. The cameras will act as
both a criminal deterrent and tool for later identification of criminal suspects. Additional
cameras should be considered to monitor other areas of the complex, such as other ground-
floor entry doors, if access is not limited to the front entry after dark, and any vending area
lacking direct surveillance by front desk personnel.
25.
The applicant shall provide a clearly designated security person 24 hours daily, 365 days per
year. This may be accomplished through use of shuttle drivers, maintenance, or management
personnel, etc. The complex shall employ a uniformed security person from at least 7:00 pm
to 6:00 am to patrol the parking areas, hallways, and other public areas on site. Security
activities shall be coordinated with other hotel and site security personnel in the Oyster Point
Area.
26.
Access into miscellaneous storage, linen, laundry, food and beverage storage areas shall be
strictly controlled.
27.
As much care as possible shall be taken not to impair the view of the registration desk and
lobby areas by passing patrol units outside the business. Use of such vision restrictors, as
potted plants, draperies, reflective window treatments, etc. Should be closely monitored.
28.
The elevators in the complex shall be equipped with convex mirrors to allow persons to view
the interior of the car before entering.
29.
All motel property should be marked with a unique identification number with a detailed
inventory (with serial numbers listed) kept on appropriate items subject to a high risk of
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 14 of 16
theft. If a commercial identification number is desired, call the Crime Prevention Unit at
877-8927 for details.
30.
Motel guests shall be provided with the ability to lock valuables in safety deposit boxes in
the office area or safes in their room. The safety deposit boxes shall be closely controlled
by designated hotel management staff.
31.
Any vending machines installed on site should be positioned in such a location that they are
visible to passersby and/or the registration desk and shall be emptied of money daily and sign
posted to indicate this provision. These machines shall be monitored by the CCTV
applications.
32.
The applicant shall have the responsibility of assuring that the perimeter of the construction
site is fenced during construction with security lighting and guard patrols employed as
necessary. If the general contractor is assigned this responsibility, it shall be the applicant's
responsibility to assure compliance.
33.
The applicant shall masterkey all entry and exit doors to only allow access to the building or
common use rooms (recreation) or guest rooms with guest room keys only and shall institute
a policy to always keep all doors (except the main entry doors) closed and locked at all times.
Building access doors from covered parking areas shall be equipped with self-closing
devices.
34.
The applicant shall install a system which will allow the individual guest room locks to be
easily rekeyed on a frequent basis. (A computer based card access system or a hard key
computer based system is encouraged. These systems allow the television theft alarms,
smoke detectors, and any emergency type alarm systems to be reported to the front desk
through the same remote transmission device. It also restricts the ability of hotel employees
to reenter rooms when not authorized and allows easy cancellation of keys from the system.)
If a computer based system is not feasible, then a manual system shall be instituted to rotate
locks on a regular basis by maintenance personnel or a contracted locksmith. Marking or
tagging room keys with room numbers is discouraged.
35.
The applicant shall design the registration area to provide maximum visibility into any
ground floor vending area and all entry doors.
36. Television sets in guest rooms shall be equipped with substantial lockdown devices.
37.
The applicant shall cut back the le~hand front desk wing wall for better visibility down the
meeting room corridor.
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005,
MND-9-005
Page 15 of 16
38.
No entertainment will be allowed on the premises without prior South San Francisco Police
Department approval.
39.
The stairways depicted on the garage area shall be on the exterior of the building to allow
visibility of these areas at all times.
Municipal Code Compliance
40.
The applicant shall comply with the provisions of Chapter 15.48 of the Municipal Code,
Minimum Building Security Standards Ordinance, revised May 1995. The Police
Department reserves the right to make more specific security and safety conditions upon
receipt of detailed/revised plans.
Building and Room Security Requirements
Door's
41.
Employee/pedestrian, unit entry, storage, linen, laundry, mechanical, electrical, maintenance,
and roof access doors shall be of solid core wood or hollow sheet metal with a minimum
thickness of 1-3/4 inches and shall be secured by a deadbolt lock with a minimum throw of
one (1) inch.
42.
Entrance doors into individual units shall be secured with a single-cylinder deadbolt lock
with a minimum throw of one inch, in addition to door latches with a one-half inch minimum
throw. The locks should be so constructed that both deadbolt and dead latch can be retracted
by a single action of the inside door knob.
43.
A viewing device (or peephole) shall be installed in each individual unit entrance door and
shall allow for 180° vision.
44.
180° viewing devices (or peepholes) shall be installed in office/administration/registration
area entry doors to screen persons before allowing entry.
45.
Outside hinges on all exterior doors shall be provided with non-removable pins when pin-
type hinges are used or shall be provided with hinge studs, to prevent removal of the door.
46.
Exterior doors into hotel hallways and doors leading into stairwells shall have self-locking
(dead latch) devices allowing egress to the exterior of the building or stairwell but requiring
a key to be used to gain access to the interior of the building from the outside or covered
parking areas or into the hallway from the stairwell.
Exhibit A
Proposed Conditions of Approval, GP-99-005, RZ-99-005, ZA-99-005, SPA-99-005, PP-99-005,
MND-9-005
Page 16 of 16
47.
Exterior doors into motel buildings and doors leading into stairwells shall be equipped with
self-closing devices.
Windows
48.
Windows capable of being opened shall be constructed so that when the window is locked
it cannot be lit'ted from the frame (sliding).
49. The sliding portion of a sliding glass window shall be on the inside track.
50. Window locking devices shall be capable of withstanding a force of 200 lbs. in any direction.
51.
Secondary locking devices are required on ground-floor windows and any windows
accessible from outside connecting balconies.
Numbering
52.
The address number of every commercial building shall be illuminated during the hours of
darkness so that it shall be easily visible from the street. The numerals in these numbers
shall be no less than six inches in height and of a color contrasting with the background.
53.
Each individual unit within the building shall display a prominent identification number not
less than two (2) to four (4) inches in height, which is easily visible to pedestrian traffic on
site.
Interior Lighting
54.
Stairwell, hall, and elevator lighting shall be equipped with vandal-resistant lenses and shall
remain on at all times.
55.
The covered parking areas shall be designed with grillwork over openings to control and
restrict pedestrian access to the vehicle entry driveways.
56.
The Police Department encourages the applicant and his various representatives to contact
this department for coordination and clarification of any security conditions. Or any concerns
on this project well in advance of the public hearing, building permit, and construction
phases of the project.
(Police Department Contact Sergeant Mike Massoni (650) 877-8927)