Loading...
HomeMy WebLinkAboutReso 137-1997 RESOLUTION NO. 137-97 CITY COUNCIL, CITY OF SOUTH SAN FRANCISCO, STATE OF CALIFORNIA A RESOLUTION APPROVING A SPECIFIC PLAN FOR THE BAY WEST COVE DEVELOPMENT WHEREAS, Bay West Cove, LLC has submitted a proposed Specific Plan for the Bay West Cove development site; and, WHEREAS, an Environmental Impact Report has been prepared which analyzes the anticipated environmental effects of the proposed Specific Plan; and, WHEREAS, the Planning Commission held a public hearing on the proposed Specific Plan on November 20, 1997 and, with minor amendments, recommended approval to the City Council; and, WHEREAS, the Planning Commission did hear and use their independent judgment and considered all said reports, recommendations and testimony hereinabove set forth; and, WHEREAS, the City Council held a public hearing on the proposed Specific Plan on December 10, 1997; and, WHEREAS, the City Council did hear and use their independent judgment and considered all said reports, recommendations and testimony hereinabove set forth; and, WHEREAS, proper notice of all said hearings were given in all respects as required by law; and WHEREAS, the proposed Specific Plan, as amended, is consistent with the East of 101 Area Plan (General Plan) as amended. NOW, THEREFORE, BE IT RESOLVED that the South San Francisco City Council does hereby find that: Proper environmental documentation has been prepared on the proposed General Plan Amendment in accord with the California Environmental Quality Act. The proposed Specific Plan is consistent with all other goals, policies and implementing programs set forth in the East of 10! Plan. Co The proposed Specific Plan will not have a substantial adverse affect on health or safety or be substantially detrimental to the public welfare or be injurious to property or public improvement. BE IT FURTHER RESOLVED that theSouth San Francisco City Council does hereby approve the Bay West Cove Specific Plan, as set forth in Attachment 1 and as amended by Attachment 2, both of which are incorporated herein by reference. ATTACHMENT I TO RESOLUTION NO. 137-97 SPECIFIC PLAN for Bay West Cove South San Francisco, California NOVEMBER 7, 1997 Prepared by ARCHITECTS 785 Market Sfreet San Francisco, California Bay West Cove Specific Plan South San Francisco, California TABLE OF CONTENTS 1. INTRODUCTION 1.1 Project Location 1.2 Objectives of the Project 1.3 Objectives of the Specific Plan 1.4 Organization of the Specific Plan 1.5 Relationship of the Specific Plan to the East of 101 Area Plan 1.6 Environmental Review 1.7 Existing Site Conditions 2. LAND USE COMPONENT 2.1 Land Use Program 3. SITE PLANNING DEVELOPMENT STANDARDS 3.1 Site Planning 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 3.1.7 3.1.8 3.1.9 3.1.10 3.1.11 3.1.12 Permitted Uses Development Intensity Open Space Setbacks Building Height Parking and Circulation Service Parking and on-site Circulation Service Area at Auto Sales Emergency Vehicle and Trash Truck Clearances Minimum Sight Distance Clearances Lighting and Illumination Cart Storage 3.2 Landscape Design 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6 3.2.7 Objectives Standards Landscape Zones Plant Material List Amenities Landscape Irrigation Landscape Maintenance 4. ARCHITECTURE GUIDELINES 4.1 Objectives 4.2 Standards 4.3 Material Palette 4.4 Graphics, Signage 4.5 Screening of Exterior Electrical Equipment and Transformers 4.6 Retaining Walls November 7, 1997 Page 1 .' Bay West Cove Specific Plan South San Francisco, California TABLE OF CONTENTS (continued) 5. OPEN SPACE AREA 5,1 Pedestrian Access 5.2 Shoreline / Marsh 5.3 Wetlands Mitigation Area 6. TRANSPORTATION AND CIRCULATION 6.1 Existing Conditions 6,2 On-Site Circulation System 6.2.1 6.2.2 6.2.3 6.2.4 6.2.5 6.2.6 6.2,7 6.2.8 6.2,9 6.2.10 Objective Ingress and Egress from Oyster Point Boulevard Primary Thoroughfares Standards Pedestrian Access Transportation Access Accessibility Guidelines Service and Loading Area Refuse Collection Areas Bicycle Parking 7. INFRASTRUCTURE 7,1 Communication Devices 7.2 Grading and Drainage 7,3 Water 7.4 Gas and Electric Service 7.5 Telephone 7.6 Sanitary Sewer 8. PUBLIC SERVICES 8.1 Police Services 8.2 Fire Prevention and Protection 8.3 Solid Waste Disposal 9. ADMINISTRATION/IMPLEMENTATION 9.1 General Methods to implement 9.2 Precise Plans 9.3 Conditional Use Permits 9.4 Parcel Maps 9.5 Sign Permits 9,6 Environmental Review 9.7 Amendments to the Specific Plan November 7, 1997 Page 2 Bay West Cove Specific Plan South San Francisco, California 1. INTRODUCTION The Bay West Cove development is seen as a gateway into the Oyster Point area of South San Francisco. The specific plan area is made up of approximately §2 acres, bounded by Oyster Point Boulevard on the south, U.S. Highway 101 on the west, the San Francisco Bay on the north and adjacent industrial development on the east. As of this writing, the specific plan area is currently vacant land, formerly the site of the United States Steel Pipe and Steel Fabrication Plant, active until 1978. The site lies within a Redevelopment Project Area under the jurisdiction of the South San Francisco Redevelopment Agency. 1.1 Project location Regional: The Bay West Cove area is located in the city of South San Francisco, approximately 3 miles south of the San Francisco city limits. Primary vehicular regional access is provided via U.S. Highway 101. See Figure 1. City_: The site is located on the north side of Oyster Point Boulevard, directly east of U.S. Highway 101. The prominence of its location is of particular importance. The visual access from highway 101, and the site's development reflects a quality project consistent with the objectives of the East of 101 Area Plan. Direct access is from Oyster Point Boulevard, via a freeway off-ramp from northbound 101. See figure 2. Site Context: The Bay West Cove project site is bounded by Oyster Point Boulevard on the south, U.S. Highway 101 and Southern Pacific railroad right-of-way on the west, the San Francisco Bay on the north and adjacent industrial development on the east. The geographic area lying east of U.S. 101 in the city of South San Francisco is envisioned as a major employment and commerce center in the community. Major users in the area consist of Genentech, a biotechnology firm and many other leading industries. Other significant uses include the Oyster Cove Marina (private) and the Oyster Point Marina (public). November 7, 1997 Page 3 Bay West Cove Specific Plan South San Francisco, California ) NAPA ./ SAN RAFAEL "BEMCIA RICHMOND WALNOT CREEK NORTH ~ A~~ PROJECT LOCATION [, H ~"~MATEO i ' ~ $~n ~ Co. FREJVlONT FIGURE NO. 1 NOT TO SCALE REGIONAL MAP ~) I..I~ER~ORE SAN .lOSE November 7, 1997 Page 4 Bay West Cove Specific Plan Sauth San Francisco, California ~TEWAy S~ arum, NORTH ! ~. SRAPROPERTY. FIGURE NO. 2 NOT TO SCALE EAST 101 PLANNING AREA 4ET-FUEL November 7, 1997 Page r Bay West Cove Specific Plan South San Francisco, California · I I SAN FRANCISCO BAY NORTH APPROIMATELY 52 ACRES (EXCLUDING STREET EXPANSION) FIGURE NO. 3 NOT TO SCALE CONCEPTUAL SITE PLAN November 7, 1997 Page 6 Bay West Cove Specific Plan South San Francisco, California 1.2 Objectives of the Project: The applicant has identified the following objectives for the Project: Convert the site from its current status as a stagnant former industrial property to an economically-feasible, quality development. Make the site esthetically more pleasing. Generate net tax revenue from the development project. Balance the payment of development fees with the benefits to the site of public works projects and off-site improvements desired by the City of South San Francisco. Build a project that has the quality of design that is called for in the Design Policies and Guidelines of the East of 101 Area Plan. Build a project that creates quality jobs for South San Francisco. Provide for the development of more retail services to serve the employees of the East of 101 Area. Mitigate circulation system impacts of the project by maintaining acceptable levels of service for streets and intersections. Encourage the enjoyment of the San Francisco Bay shoreline and views of the Bay by completing the segment of the Bay Trail through the property, in cooperation with Bay Conservation and Development Commission. November 7, 1997 Page 7 Bay West Cove Specific Plan South San Francisco, California 1.3 Objectives of the Specific Plan: Implement the East of 101 Area Plan. The East of 101 Area Plan, adopted in 1994, establishes comprehensive land uses, circulation patterns and policies on a wide range of development and conservation issues. The Specific Plan is a tool used to promote compliance with the requirements and general policies for the East of 101 Area Plan. The intent of the Specific Plan is not to reexamine the East of 101 Plan's policy direction, but rather to create a document that will add detail and implementation programs for the Bay West Cove site. Section 1.4 below describes in greater detail the relationship of the Specific Plan to the East of 101 Area Plan. Provide for Efficient Extension of Services and Infrastructure. One aspect of achieving the two purposes listed above is to provide for efficient extension of services to those properties in the Plan area that are designated for urban development and to ensure that the intensity of site development does not overtax utility, transportation systems, or on-site parking areas. Provide for a Comprehensively Planned Development. A primary reason for preparing the Specific Plan is to facilitate subsequent review and approval of applications for development consistent with Specific Plan policies. The technical analyses conducted as background for this document investigated the factors relevant to planning for future development. By addressing land use regulation, circulation, utilities and environmental factors, the Specific Plan and accompanying environmental impact report (EIR) remove the need for each applicant to independently conduct such studies. Resolving in advance potentially controversial issues related to these topics, also reduces the possibility of time-consuming delays because of disagreement about project impacts. Ensure Coordination of Planning Efforts with Other Local, State and Federal Agencies. Through the course of site plan design, remedial action plan implementation and preparation of the grading plan, all relevant local state and federal agencies have been kept apprised of the project. The project will continue to coordinate the lawful requirements of all necessary permits from the relevant agencies. Provide a Mechanism for Flexibility in the Long Term Development of Land Uses, Within the Bounds Established in the Specific Plan. Refer to Figure No. 4 November 7, 1997 Page 8 Bay West Cove Specific Plan South San Francisco, California 1.3 Objectives of the Specific Plan - continued: Provide a Description of the Project Allowing for Comprehensive Environmental Reviews and Inclusion of Mitigations into the Plan. Adoption of a Specific Plan is defined as a project under the California Environmental Quality Act (CEQA). An initial study prepared by the City determined that the project required the preparation of an Environmental Impact Report to access potential project impacts and identify mitigation measures. The E.I.R. will allow for the review of impacts of the entire project as well as Individual projects completed over time. Further environmental documentation may not be necessary or abbreviated for individual projects which have been evaluated as part of the overall project. 1.4 Organization of the Specific Plan: This document is intended to be easily understood and useful to readers, while satisfying the requirements of State law pertaining to the content of Specific Plans. The table of contents lists the Specific Plan's major sections. The Specific Plan includes background text, policy statements, and information presented in tables, figures, maps and diagrams. As described below, the requirements contained herein are required to be consistent with the East of 101 Area Plan. Equally important is the requirement that city actions on development projects and off-site improvements be consistent with this Specific Plan and the East of 101 Area Plan. The words used in this document convey the weight given to each, as follows: "Shall, "musf' and "will" signify requirement to be met without exception under all relevant circumstances. "Should" signified the city's desire and expectation that the requirement will be met in most cases but recognizes that some circumstances may make implementation impossible or unwise. The applicant may be required to demonstrate to the city the reason for not implementing principles. '"May" signifies guidance for actions that are at the discretion of the applicant or city. November 7, 1997 Page 9 Bay West Cove Specific Plan South San Francisco, California 1.5 Relationship of the Specific Plan to the East of 101 Area Plan: 1.5.1 Consistency with the East of 101 Area Plan The Specific Plan must be consistent with the East of 101 Area Plan, as required by State law. The meaning and types of consistency are discussed in the East of 101 Area Plan. 1.5.2 Need to Refer to the General Plan One East of 101 Area Plan requirement that does not apply to the Specific Plan is comprehensiveness. The East of 101 Area Plan addresses all geographic areas as described in the document, as well as issues relevant to development and conservation in the East of 101 Area. This Specific Plan provides detailed requirements and programs on the topics of greatest importance to the future of the Bay West Cove development, and does not cover all topics addressed in the East of 101 Area Plan. Users of the Specific Plan must therefore refer to the East of 101 Area Plan to identify the city's policies relevant to activities in the Specific Plan area. 1.5.3 Amendments to the East of 101 Area Plan Concurrent with Specific Plan adoption will be adoption of amendments to the East of 101 Area Plan, as recommended in the E.I.R. to mitigate impacts of the project. November 7, 1997 Page 10 Bay West Cove Specific Plan South San Francisco, California 1.6 Environmental Review: An Environmental Impact Report (EIR) has been prepared to assess the potential environmental impacts associated with the Bay West Cove project. The EIR has been prepared in accordance with the standards and procedures set forth in the California Environmental Quality Act (CEQA).~ ~ Morehouse Associates November 7, 1997 Page 11 Bay West Cove Specific Plan South San Francisco, California 1.7. Existing Site Conditions: 1.7.1 Topography The site is generally level except where demolition debris has been placed, creating mounds of varying size or where excavations have created depressions of varying depth and lateral extent. The south east corner of the site slopes gently upwards to the south, rising from approximately six feet above mean high water to approximately 40 feet above mean high water in the southeast corner. Elevations in the southwest corner range from approximately 8 feet above mean high water to 12 feet above mean high water. The northern portion of the site ranges from approximately 6 to 7 feet above mean high water, with rubble piles up to approximately 18 feet above mean high water? 1.7.2 Existing Site Uses From 1938 to 1978 the site was operated by U.S. Steel Corporation, now a subsidiary of USX Corporation, and used for steel and pipe fabrication and assembly. Liberty ships were repaired there during World War II. Toxic chemicals used during these operations contaminated soils over the site and near shore baylands? The site is currently empty, as all buildings were demolished in the mid-1980s.' 1.7.3 Wetlands: A number of small, scattered wetlands are found on the site. A proposed wetlands determination has been prepared for approval by the U.S. Army Corps of Engineers. Approximately 0.4 acres of tidal wetlands below High Tide Line (5.0 feet) were identified. Tidal wetlands occur in a few scattered areas along the property's shoreline. Approximately 0.6 acres of non-tidal wetlands were found in depressions in 1986. An additional 2.0 acres were identified that are defined as "non-tidal exempt," because they were created by construction activity. Site remediation will result in the removal of these wetlands.5 However, replacement wetland areas will be provided on or immediately adjacent to the project site, as described in Sec. 1.6.6. 2 Morehouse Associates ~ Morehouse Associates ' Morehouse Associates ~ Morehouse Associates November 7, 1997 Page 12 Bay West Cove Specific Plan South San Francisco, California 1.7. Existing 1.7.4 1.7.5 1.7 Existing Site e Tre~ldwell & Fiollo Site Conditions - continued: Site Remediation Previous studies have identified soil and sediment contamination at the site. The principal contaminants are petroleum hydrocarbons and metals in the soil, and polychlorinated blphenols (PCBs) in the off-shore sediment. The site has been issued Order No. 96-102 by the California Regional Water Quality Control Board (RWQCB), San Francisco Bay Region, requiring spot removal and immobilization of petroleum hydrocarbon and lead contaminated soil, and spot dredging and encapsulation of contaminated sediment. Sediments placed in the slot (area designated as marsh - Figure No. 3) will be capped with bay mud, sand and gravel or combination thereof to isolate the contaminated sediments from marine organisms and to prevent the migration of contaminants into the bay, Wetlands sufficient to replace the onshore and tidal wetlands to be filled dudng site mitigation and development will be constructed in the launch basin and in the vicinity of the storm water ouffall, resulting in a net gain of wetlands at the site. The Army Corps of Engineers, San Francisco District, has granted the project authorization to dredge and fill the slot and areas outside the slot under 33 CFR 330 Appendix A, Department of the Army Nationwide Permit 38, Cleanup of Hazardous and Toxic Waste. Section 401 Water Quality Certification has been granted by the RWQCB? Hazardous Material Remediation Approximately two feet of soil within 100 feet of the slot will be excavated and used as fill material away from the shoreline. Portions of the removed shoreline contain contaminates that will be encapsulated away from the shoreline. Pockets of high concentration of hydrocarbons and lead elsewhere on the site also will be excavated and stabilized. Clean fill will be placed across the entire site to accomplish the encapsulation, consistent with the final grading plan. Remediation of off-shore toxins will consist of dredging contaminated sediment from the area of the former acid waste and storm drain ouffall and former ship channel, and placement in the back of the channel where it will be covered with approximately 1 to 3 feet of clean sand and gravel. The Conditions - continued: November 7, 1997 Page 13 Bay West Cove Specific Plan South San Francisco, California 1.7.6 dredged areas will also be covered with 2 to 3 feet of clean sand and gravel7 Wetlands Replacement Wetlands and tidal waters of the United States are protected by the U.S. Army Corps of Engineers, through provisions of Section 404 of the Clean Water Act. If wetlands under the jurisdiction of the Corps of Engineers are filled, they normally must be recreated on the same site, if feasible. The applicant has proposed to provide compensatory mitigation for all wetlands which would be filled in the by the Project, totaling about 3 acres, including the non-tidal wetlands. The Corps has approved and been a party to the Water Board's final order to clean up the site, which includes the replacement of approximately 3 acres of filled wetland with a net gain of recreated tidal wetlands. Mitigation will occur in two areas: within the slot and along the shoreline just east of the mouth of the slot. Both mitigation measures will involve containment of contaminated soils through either removal of soils or capping them with several feet of engineered fill. A new emergent marsh wetland will be created in the slot, in tidal waters, which will be filled with about 30,000 cubic yards of sediments which includes the toxic material dredged from the ouffall area and capped with clean imported sand and gravel. The fill will descend in elevation from the back of the slot to where it meets the Bay, allowing for tidal action within the slot. The shoreline mitigation area at the former storm drain ouffall will create a net gain of tidal marsh. At least two feet of soil within 100 feet from the existing shoreline will be removed. Dredged backfill material that meet standards set by the Regional Water Quality Control Board for placement for the purposes of creating tidal wetlands will be placed within a band along the shoreline and 50 to 300 feet offshore. Clean material over the capping material will be placed to a depth of 3.5 to 8 feet in order to provide a substrate for marsh plant development.8 2. LAND USE COMPONENT ' Treadwell & Rollo 8 Treadwell & Rollo November 7, 1997 Page 14 Bay West Cove Specific Plan South San Francisco, California 2. LAND USE COMPONENT 2.1 Land Use Program The 52 acre Bay West Cove project is located at one of the primary entrances to the Oyster Point Boulevard portion of South San Francisco as well as being immediately adjacent to San Francisco Bay. Recognizing this prime location, the development offers a high quality setting for a variety of retail, lodging, restaurant, entertainment and similar users taking advantage of the natural setting. Bay West Cove offers a combination of building types ranging in size, location and function. The project incorporates vehicular, service, pedestrian into the plan as well as various site amenities including public access to the Bay, pedestrian pathways and landscaped plazas and gathering places. Land uses proposed within the project include fall under the category of Planned Commercial as identified in the East of 101 Area Plan. Uses allowed under this category include hotels and motels, sales and service of new and used automobiles, offices, business and professional services. To assist in the more detailed planing of the Bay West project, the site has been divided into various Planning Areas, with more specific uses anticipated in each of these Areas. Figure No. 4 delineates the location and extent of each of the Planning Areas. The Bay West Cove Specific Plan anticipates the following uses within the Planning Areas as follows: · Planning Area 1:20 acre site Commercial and Auto Sales use with a capacity of 90,000 square feet of building area. · Planning Area 2:19.2 acre site Alternate No. 1 Commercial Retail use with a capacity of 244,372 square feet of building area (33% coverage). Alternate No. 2 Commercial Retail use with a capacity of 175,000 square feet of building area with the addition of Hotel use with a capacity of 184,258 square feet. November 7, 1997 Page 15 . - Bay West Cove Specific Plan South San Francisco, California Planning Area 3:4.6 acre site Alternate No. 1 Commercial Retail use with a capacity of 61,420 square feet of building area (33% coverage). Alternate No. 2 Hotel use with a capacity of 204,732 square feet (100% coverage). Planning Area 4:8.5 acre site Alternate No. 1 Commercial Retail use with a capacity of 222,156 square feet of building area (60% coverage). Alternate No. 3 Hotel use with a capacity of 370,260 square feet (100% coverage). Planning Area 5: No Development Proposed November 7, 1997 Page 16 Bay West Cove Specific Plan South San Francisco, California ALT. 3 - HOTEL - ~0,2~0 SF (100'/* COVERAGE) NOTE THE ~OVE I..N~D. USE DESCRIP/1ON !NCI.UOES UP TO I~OO 8F. O~ FREESTNdDING I~OROSED FOOO SERVlCE. o! /' PLANNING AREA 5 NO DEVELOPMENT SAN FRANCISCO BAY °° /° %, % ./ . ~ I .*' , '~.': ./ , .,' - PLANNING AREA 1 +/-20.0 ACRES t I I PLANNING AREA +/-19.2 ACRES STREET EXPANSION +/' 3.1 ACRES OYSTER POINT BLVD. NORTH APPROXIMATELY 52 ACRES (EXCLUDING STREET EXPANSION) FIGURE NO. 4 NOT TO SCALE LAND USE CONCEPT November 7, 1997 Page 17 Bay West Cove Specific Plan South San Francisco, California 3. SITE PLANNING DEVELOPMENT STANDARDS 3.1 Site Planning: 8.1.1 Permitl'ed Uses: Planned Commercial: Uses allowed in the Bay West Cove Planned Commercial category shall typically include hotels and motels, retail uses including new and used automobile sales and services, office development, restaurants, administrative services, business and professional services, convenience sales, financial services personal and repair services, and shoreline oriented recreation.° Ancillary and accessory uses normally and customarily associated with any of the above uses shall also be permitted, as well as parking facilities to serve any of the uses. Drive through facilities will require a Conditional Use permit. Refer to Figure No. 4 3.1.2 Development Intensity Planned Commercial Category Uses: The maximum allowed Floor Area Ratio in the Planned Commercial category is 0.60. Additional floor area, up to a maximum Floor Area Ratio of 1.0, may be permitted for hotels and motels meeting the city's development requirements. Such additional floor area shall be subject to an approved conditional use permit.'° Planned Industrial Category Uses: The maximum allowed Floor Area Ratio in the Planned Industrial category is 0.55. Structured parking areas ancillary to the main use(s) on a site are excluded from the Floor Area Ratio calculations." Consistency with Environmental Impact Report: The maximum development intensity of individual land uses, or combinations of land uses, shall be consistent with the Bay West Cove Environmental Impact Report in terms of maximum traffic generation, air quality emissions, use of water services, generation of waste water and off-site flow of storm water run- off. 3.1.3 Open Space East of 101 Area Plan East of 101 Area Plan East of 101 Area Plan Open spaces shall be integrated with pedestrian walks and defined by landscaping and other elements to create a sense of place. Additionally, they will provide pedestrian linkage between on-site gathering areas. November 7, 1997 Page 18 Bay West Cove Specific Plan South San Francisco, California $.1 Site Planning - continued: 3.1.3 Open Space - continued: Open spaces shall be accessible to the public, be highly visible and well lit. Benches, light standards, kiosks, drinking fountains, trash receptacles, and other street furniture in on-site open spaces shall be designed in a coordinated fashion to enhance the appearance and function of the site and open space. 3.1.4 Setbacks Building Setbacks Oyster Point Boulevard: Twenty feet (20') from property line. West Property Une: Twenty feet (20') from property line. East Property Line: Twenty feet (20') from property line. Main Through Road: Ten feet (10') from back of curb. Southwest edge of main through road will incorporate a 5'-0" concrete sidewalk (15'-0" overall dimension). Other: For buildings exceeding 2 stories or thirty-five feet (35') as measured from the highest finish grade, whichever is more restrictive, an additional one foot (1') of setback as measured from the face of curb shall be required for each additional one foot (1 ') in height above thirty-five feet (35'). Activities that can occur within the building setbacks identified above are landscaping, pedestrian walkways, gathering areas, utility equipment and parking. Bay Conservation and Development Commission (BCDC) jurisdictional area development will comply with requirement established by BCDC pertaining to the BCDC jurisdictional area. The BCDC jurisdictional area is located within 100"-0" of the mean high tide line. Commercial improvements located within the shoreline band are permitted by BCDC on a case-by-case basis. The City of South San Francisco may similarly permit improvements within the shoreline band and as permitted by the amended East 101 Plan. November 7, 1997 Page 19 Bay West Cove Specific Plan South San Francisco, California $.1 Site Planning - continued: 3.1.4 Setbacks - continued: Landscape Setbacks Oyster Point Boulevard: Twenty feet (20') from property line. West Property Line: Ten feet (10') from property line. East Property Line: Ten feet (10') from property line. Bay Shoreline and Marsh: Thirty-five feet (35'). Main Through Road: Ten feet (10') from back of curb. Southwest edge of main through road will incorporate a 5"-0" concrete sidewalk (15'-0" overall dimension). Activities allowed within landscape setbacks identified above are landscaping, pedestrian walkways, driveways, gathering areas and utility equipment. Interior Property Line Setbacks Interior property lines shall be as required by the Uniform Building Code, as enforced by the city of South San Francisco. When possible, buildings should be continuous structures with four 60 foot minimum side yards. November 7, 1997 Page 20 X SETBACKS Oyster Point Blvd. West Property Line East Property Line Main Through Road Bay Shoreline & Marsh BUILDING LANDSCAPING 20' 20' 20' 10' 20' 10' 15' 15' See Note Below 35' COMMENTS Refer to Figure No. 5 cQ Note: Bay Conservation and Development Commission (BCDC) jurisdictional area development will comply with requirement established by BCDC pertaining to the BCDC jurisdictional area. The BCDC jurisdictional area is located within 100'-0" of the mean high tide line. Commercial Improvements located within the shoreline band are permitted by BCDC on a case-by-case basis. The City of South San Francisco may similarly permit improvements within the shoreline band and as permitted by the ammended East 101 plan. 7 Bay West Cove Specific Plan South San Francisco, California PARKING LOT \ CANOPY TREE ~ · .~, MOUNDED' BUFFEJ ~_~,~ BUILDING EDGE "-~}~~ < LANOSC. A_P.E_.SETBACK ~ PUBLI(3 R.O.W. 20' MIN. STREETSCAPE ZONE PUBLIC WALK OYSTER POINT BOULEVARD FIGURE NO. 5A BUILDING SETBACK PARKING LOT \ CANOPY TREE , '.A'¢, ,.V . ~ 2'~ CAR OVERHANG STANDARD LUMINARE W/ SHARP CUT OFF LAMP PUBLIC WALK LANDSCAPE SETBACK ~o' ~iFL PUBLI~ R.O.W. STREETSCAPE ZONE OYSTER POINT BOULEVARD FIGURE NO. 5B -- > LANDSCAPE SETBACK November 7, 1997 Page 22 Bay West Cove Specific Plan South San Francisco, California 3.1 Site Planning - continued: 3.1.5 Building Height Objective To maintain a reasonably consistent and compatible height profile throughout Bay West Cove. Standards Maximum heights of buildings in the East of 101 Area shall not exceed the maximum heights established by the Airport Land Use Commission based on Federal Aviation Regulations Part 77 Criteria? Maximum Building Heights (including mechanical equipment screen, if utilized): Single Story Big Box Retail: 40 feet top of parapet or roof, plus 15 feet architectural elements. Single Story Retail: 40 feet. Hotel: Per Federal Aviation Regulations noted above. '3~1 FEET ', r "i -- ...- ." '"-5 ..... .<'.~ . ~/ ,:..'., .- .' . .~. ',. , ~... ~' 1.:. . '~... ..? FIGURE NO. 5D FAA HEIGHT RESTRICTION MAP East of 101 Area Plan, Policy LU-23, p.65. November 7, 1997 Page 23 Bay West Cove Specific Plan South San Francisco, California 3.1 Site Planning - continued: 3.1.6 Parking and Circulation Objectives To provide sufficient on-site parking to accommodate all vehicles associated with the use of each lot at any one time. b. To provide a layout to facilitate easy and safe pedestrian circulation. c. To provide even distribution throughout, based on the specific tenant requirements. To minimize vehicle noise, lights, and glare onto adjacent properties. To comply with the City of South San Francisco Zoning Ordinance. Standards All uses located in Bay West Cove shall provide on-site parking and loading facilities in accordance with required city parking ordinance and the Bay West Cove Specific Plan. Convenient pedestrian circulation shall be provided throughout all projects to connect parking areas and public transit facilities with buildings and pedestrian open spaces. Parking stall requirements within the Bay West Cove development are subject to the guidelines established in the South San Francisco Municipal Code and the East 101 Area Plan. Parking stall calculations will be based on gross leasable area (GLA). Parking standard stalls shall be 8'-6" x 18'-0", unless tenant specific criteria dictates larger stall sizes. Aisle widths shall be as follows: Stall Angle One Way Aisle Two Way Aisle 90° 25"-0" 25'-0" 60° 21'-0" 25'-0" Verify with the City of South San Francisco Zoning Ordinance. November 7, 1997 Page 24 Bay West Cove Specific Plan South San Francisco, California 3.1 Site Planning - continued: 3.1.6 Parking and Circulation - continued: Standards - continued: A two foot (2') overhang is permitted into adjacent landscape areas where landscaping width is six foot (6'-0") or greater. Parking spaces required for public shoreline access shall be convenient to the shoreline and shall be properly and clearly marked and sign posted per Section 21113(a) CVC. The minimum size of fire lanes shall be 20'-0". Where fire lanes are bordered by walls, (20 feet clearance, wall to wall), or to structure, an additional 5-10 feet shall be provided between fire lanes and structures to provide room for laddering buildings and other fire ground operations. Designated "Accessible Parking" spaces and signage shall be provided to meet current California State Code of regulations Title 24, Part 2. In addition to the above referenced requirement one in every eight accessible stalls required must meet van access standards. Total No. of Parking Stalls in Lot Min. Req, No. of Accessible Spaces 1-25 1 26-50 2 51-75 3 76-100 4 101-150 5 151-200 6 201-300 7 301-4130 8 401-500 9 501-1,000 2% of total 1,001 and over Twenty plus one for each 100, or fraction thereof over 1,001. The above standards have been taken from the 1994 Uniform Building Code - Section 1129B (Accessible Parking Required) - Table 11B-7 Designated '"Bicycle Parking" areas should be considered for the convenience of employees using bicycles. In order to avoid the clutter of bicycles parked in unplanned locations, bicycle parking areas shall be conveniently located next to employee entrances and be provided with racks having security locking capabilities. November 7, 1997 Page 25 Bay West Cove Specific Plan South San Francisco, California 3.1 Site Planning - continued: 3.1.6 Parking and Circulation - continued: Standards - continued: Parking areas shall be screened from view from streets and adjacent property by landscaping including berms where appropriate. k. Avoid dead end parking aisles. 3.1.7. ~;ervice Parking and on-site Circulation Objectives To ensure that service and loading areas are not visible from streets, entry drives, common area spaces and recreational areas, etc. To ensure that service and loading areas are located within a site so as to minimize the visibility of loading and service vehicles from primary view areas. To ensure that the service and loading areas are designed and located on the site so that service vehicle activities and movement do not disrupt the efficient flow of-on-site and off-site traffic. Orient loading to the rear or side of the project whenever possible. Where it is necessary for loading areas to face a street and/or bay, screen them with walls and decorative gates or landscaping. Refer to Figure No. 6. Standards a. All loading facilities and maneuvering areas must be on site. b0 All loading facilities shall be permitted only in the rear or side yard areas, refer to section 3.1.7. Aisle width to loading docks shall be a minimum of 30' (verify.) wide. Loading docks shall be set back a minimum of 60' (verify) from the northerly right of way line of Bay West Cove Boulevard. November 7, 1997 Page 26 Bay West Cove Specific Plan South San Francisco, California 3.1 Site Planning - continued: 3.1.7. Service Parking and on-site Circulation - continued: Standards - continued: Loading facilities shall be adequately screened from the public view through the use of screen walls and landscaping. Minimum aisle width adjacent to loading areas, without dock high doors, shall be 16' one way and 28' for two way. Provisions shall be made on each site for any necessary vehicle loading. On-street vehicle loading shall be prohibited. No street parking, staging and maneuvering by delivery trucks will be permitted in order to access loading docks unless within designated truck maneuvering areas. Truck dock and loading zones are subject to individual evaluation by the City of South San Francisco Traffic Department. j. No truck docks or loading areas will face the Bay. DASHED UNE REPRESENTS TRUCK _ RECESSED TRUCK WELL (4'-0") EANDSCAPE SCREENING SERV1CE ROAD FIGURE NO. 6 LOADING FACING STREET (LANDSCAPE SCREENING) November 7, 1997 Page 27 Bay West Cove Specific Plan South San Francisco, California $.1 Site Planning - continued: 3.1.8. Service Area at Auto Sales An 8'-0" high masonry screen wall will be located adjacent to the south~,esterly edge of the main access road for purposes of screening the auto sales service areas. This wall will be setback from the main access road approximately 15'-0" to incorporate a 10'-0" landscape interior zone and a 5'-0" concrete sidewalk for pedestrian access. MOUNDED BUFFERW/ , LANDSCAPING CONCRETE MASONRY . SCREEN WALL AUTO SALES AND SERVICE AREA CANOPY TREE CONCRETE SIDEWALK LANDSCAPE SETBACK (10'~.15') 5'-0" MAIN ACCESS DRIVE FIGURE NO. 7 SCREENING OF AUTO SALES SERVICE AREA November 7, 1997 Page 28 Bay West Cove Specific Plan South San Francisco, California 3.1 Site Planning - continued: 3.1.9. Emergency Vehicle and Trash Truck Clearances Parking lot layouts and service areas must be designed to accommodate emergency vehicles and the appropriate service vehicles. Confirm required clearances and turning radii with the City of South San Francisco. 3.1.10. Minimum Sight Distance Clearances A clear sight area shall be established at all intersections of public or private streets within the each planning area. This area shall be defined by a line in a horizontal plane, taken at a forty-five (45) degree angle, connecting two points twenty-five (25) feet from the intersection of the property lines or the prolongation of such lines. The maximum height of visual barriers, including but not limited to signs, vegetation, fences and walls, shall not exceed thirty-six (36) inches above the top of the curb or forty-four (44) inches above the surface of the street. PJGHT-OF'-I~AY' FIGURE NO. 7B SETBACK FOR CLEAR SIGHT TRIANGLE November 7, 1997 Page 29 Bay West Cove Specific Plan South San Francisco, California 3.1 Site Planning - continued: 3.1.11 Lighting and Illumination Parking lots, driveways, circulation areas, aisles, passageways, recesses and ground contiguous to buildings shall be provided with high intensity discharge lighting with sufficient wattage to provide adequate illumination to make clearly visible the presence of any person on or about the premises during the hours of darkness and provide safe, secure environment for all persons, property and vehicles on site. Such lighting shall be equipped with vandal-resistant covers. The following minimum illumination levels shall be achieved. Open Parking Lot: One (1) to two (2) foot-candles minimum maintained at ground level. Pedestrian Pathways/Bay Path: One-half (.5) to one (1) foot-candle minimum maintained at ground level. Covered Parking: Five (5) foot-candles minimum maintained at ground level. Proposed lighting design shall be sensitive to reducing glare and negative light intrusion on adjacent properties. 3.1.12 Cart Storage Cart storage areas shall be located conveniently throughout the parking area (Refer to Figure No. 22B). When cart storage areas are located in sidewalk along front facade of buildings, Iow decorative screening walls shall be utilized to screen carts. ELEVATION. CONCRETE CURB FINISH TO MATCH ADJACENT BUILDING -I' ! SHOPPING CART I I SECTION · ~,UILDING EDGE FIGURE NO. 7C CART STORAGE SCREENING WALL November 7, 1997 Page 30 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design The landscape at Bay West Cove is an important element in coordinating architectural massing, varied land uses and city design criteria into a unified, pleasing development with its own character. Landscape and open spaces are designed as an integral part of the overall site plan design, and will create visual interest and variety to the streetscape, enhance building architecture, screen utilities and buffer views of automobiles, pavement and service areas, and to define and to distinguish the public environment from vehicular spaces. Consideration should be given to wind protection of building and site activities by the buffer planting of wind tolerant trees and shrubs. The project architecture and building sites of Bay West Cove will most likely be varied. Landscape design will play a role in creating and conveying the overall character of an inviting public environment. The landscape serves to organize circulation patterns and define areas of differing uses and open space for public interaction. Trees, shrubs, ground covers and vines shall be used to define outdoor spaces, compliment the architecture and soften building massing. Plant materials shall be selected for their aesthetic quality, suitability for the site environmental conditions, as well as Iow maintenance and water requirements. 3.2.1 Objectives To meet or exceed the city's minimum landscape requirements for the site, including the City Water Conservation Ordinance and best management practices (BMP's) for storm water management. To provide a landscape design that creates the perception of Bay West Cove as a public environment, integrating appropriate design elements. To provide a landscape design that ensures a high visual quality of the streetscape and to provide an attractive and pleasant shopping environment. To promote a definite physical landscape link between adjoining parcels but also allowing retailers the flexibility to have individual identity. To promote the development of a landscape that has a strong aesthetic quality while at the same time remaining sensitive to Iow maintenance, Iow water requirements, and the functional uses of plants and other landscape elements. November 7, 1997 Page 31 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued: 3.2.2 Standards A minimum of 15% of the area within the property lines of the development site shall be devoted to landscape materials, inclusive of landscape setback zones. This landscaping shall be evenly distributed throughout the site. Landscape plantings shall be selected from the plant materials list within these design guidelines. Landscape phasing, if any, shall be consistent with Planning Area phasing and indicated on the landscape plans for the City of South San Francisco. 3.2.3 Landscape Zones Landscape areas for this project site are divided into three general separate zones: streetscape zone, landscape setback zone, and landscape interior zone. Each of the three general zones is broken down further into more specific categories (refer to the Plant Materials List in section 3.2.4). The division of landscape areas in this manner enhances the organization and function of site uses, and helps establish design uniformity. Descriptions of the three general zones are given below: Streetscape Zone The streetscape zone includes the transition between the Oyster Point Boulevard curb (including the public right of way) and the property line (See Figure No. 5.). It also includes the transition between interior driveways and the sidewalk or landscape setback zone. Landscape planting in this zone will be designed not only to meet City requirements, but also to uphold the character of surrounding properties and existing streetscape. The type and spacing of trees, combined with careful design of tuff, ground cover and shrub areas, will reflect the existing design character of adjacent properties. Landscape Setback Zone The landscape setback zone is the transition between the streetscape zone and the project parking lot(s) or building. Each parcel owner shall be required to provide the following: a. Transition from the streetscape to the site landscape areas shall be smooth with grades not exceeding . b. Landscape plantings shall be continuous across setback lines. November 7, 1997 Page 32 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued: 3.2.3 Landscape Zones - continued: Landscape Setback Zone - continued Surface parking areas within the landscape setback zone along major arterials shall be screened by a berm maintained a continuous 3' high, consistent with the plant list within these design guidelines. Landscape plantings shall be selected from the plant materials list under landscape setback zone. The plant materials ultimately selected shall comply with the current city of South San Francisco streetscape planting list. eo All landscaping, including street trees within the public right of way, shall be shown on the approved public improvement plans prepared by the project landscape architect. Enhanced landscape plantings and major project identification are encouraged at parcel/street corners within the landscape setback zone. Perimeter landscape phasing, if any, shall be indicated on the landscape plans. Building entrances shall be well articulated and project a formal entry statement through a variation of building form, decorative pedestrian plazas and planted areas. Complementary colors, materials and textures in conjunction with building forms is encouraged. Landscape design and plant material selection will be as appropriate for specific areas within the landscape setback zone. These areas include the railroad right-of- way setback, adjacent property setback and bay front setback. November 7, 1997 Page 33 Bay West Cove Specific Plan South San Francisco, California SAN FRANCISCO BAY NORTH STREETSCAPE ZONE LANDSCAPE SETBACK ZONE LANDSCAPEINTERIORZONE FIGURE NO. 8 NOT TO SCALE LANDSCAPE ZONES November 7, 1997 -- Page 34 Bay West Cove Specific Plan South San Francisco, California ./c^NoP¥ TREE /  , / /--sH'r~U'E~ i--iE'DGE ~.l'. ,/ i-- M, OUNDED PLANTING BUFFER I ' ' PLAN ~ ' - · .. i ' SIDEWALK -- F'l-T-ifil ELEVATION MOUNDED BUFFEr~'-,, '~,~'~. ,/~ PUBLIC WALI~ '' PARKING AR~ ~ '~ 2'~' CAR O~RHANG / ( ~NDSCAPE S~SACK ~ PUBLI~ R.O.W. 20' ~lh~ . STREETSCAPE ZONE .... OYSTER ~ BOI.,ILEVARD FIGURE NO. 9 STREET ZONE & LANDSCAPE SETBACK ZONE FIGURE NO. 10 HEDGE SCREENING IN PARKING AREAS WITHIN LANDSCAPE SETBACK ZONE November 7, 1997 Page 35 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.3 Landscape Zones - continued Landscape Interior Zone The interior zone encompasses all exterior elements within an individual parcel excluding the streetscape zone, the landscape setback zone and the building area. This zone is subject to the needs of each individual tenant and thus is meant to have a greater degree of flexibility than the streetscape or landscape setback zones. Common concerns within this zone include: landscape amenities, parking lot arrangements and planting design, site lighting, regulatory and directional signage, service area screening, and side rear property line treatment. Paving Areas: Enriched (Iow-profile) paving in parking areas, adjacent to main building entrances, plazas, outdoor eating areas and pedestrian circulation areas through parking lots is encouraged. b. Building Perimeter Planting Accent trees providing contrast in texture, color, and form to surrounding buildings and located in groups and masses are encouraged. The number of different species used shall be kept to a minimum and repetition of species is encouraged to retain continuity and conform to the harsh environmental conditions of the site. Accent shrub, vine and ground cover plantings providing contrast in texture, color, and form, grouped in masses are encouraged. November 7, 1997 Page 36 Bay West Cove Specific Plan South San Francisco, California CANOPY TREE IN TREE WELL VINE ON. TRELLIS SUPPORT ; FLOWERING SHRUBS' '1 ~, BUILDING PERIMETER ~ FIGURE NO. 1 lA LANDSCAPING AT BUILDING PERIMETER (BUILDINGS UNDER 32'-0" IN HEIGHT) CANOPY TREE IN TREE WELL VINE O~. TRELLIS SUPPORT ; FLOWERING SHRUBS' BUILDING PERIMETER FIGURE NO. 1 lB LANDSCAPING AT BUILDING PERIMETER (BUILDINGS OVER 32'-0" IN HEIGHT) November 7, 1997 Page 37 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.3 Landscape Zones - continued Landscape Interior Zone c. Parking Lot Landscape Planting Parking lot landscaping should facilitate easy and safe pedestrian circulation. A minimum of one 15 gallon tree is required per each ten parking stalls, to be placed at the end of rows, in planting '¥ingers" and/or 6'x6' tree wells aligned on striping between double rows of parking. The minimum number of parking lot trees is determined by dividing ten (10) into the total number of parking stalls. 6" CURB PLANTER "/ FOR TREES, TYP. MAX. I0 SPACES ,///,~-0" SQUARE FIGURE NO. 12 PARKING LOT TREE LAYOUT November 7, 1997 Page 38 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.3 Landscape Zones - continued Landscape Interior Zone c. Parking Lot Landscape Planting Planter areas within parking areas shall be a minimum of three feet (3') clear in width, measured from the inside of curb. A three foot (8') wide concrete walk shall be constructed inside the within planter areas at the sides of parking stalls. G ~*SQUARE FIGURE NO. 13 CONCRETE ~ ~ WIDTH PER CI1¥ STANDARD WALK ~/ ~ PLANTING AREA WIDTHS Tree wells and planter area curbs shall be used in lieu of wheel stops. Curbs for tree wells and other planter areas shall have a 6" minimum height. Concrete curbs shall be constructed in accordance with City Standard Drawing No. 20. 6' TYP. PARKING >(PLANTER PARKING 6",-0' MIN, ~< FIGURE NO. 14 PARKING LOT PLANTING AREA CURB November 7, 1997 Page 39 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2,3 Landscape Zones - continued Landscape Interior Zone d. Side and Rear Yard Landscape Planting A maximum slope of 2:1 is allowed within the side or rear yard planting zone. A one foot minimum fiat transition shall be provided at the top and bottom of all slopes within this zone. Areas along the easterly and south easterly portions of the property may require alternate retaining solutions. GROUNDCOVER SHRUB & TREE TO STABILIZE SLOPE 1'-0' MIN. FLAT ~  TOP 8( BOI'~OM ~/ SERVICE ROAD MAX.~:i SLOPE /l /! FIGURE NO. 15 SIDE &.REAR YARD PLANTING ZONE SLOPES PUBLIC ACCESS AREA '~J PARKING .. _\ PER BCDC REQUiREME="~r~-~"*~' AREA PICKLEWEED MARSH WETLAND - NATIVE UPLAND ~t~DDfllON,~I~¢ PATH ~/TU RF ~ ,~ BUFFER ~'-~' '~; STRIP' FIGURE NO. 16 SIDE & REAR YARD PLANTING ZONE ALONG BAY EDGE November 7, 1997 Page 40 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.3 Landscape Zones - continued Landscape Interior Zone d. Conceptual - Side and Rear Yard Landscape Planting At all side and rear yards, whenever development of a planted area adjacent to the property line is proposed, the design plans for each adjoining parcel shall be coordinated for consistency. Tree species shall be selected for continuity. The number of different species shall be kept to a minimum. Accent shrub, vine and ground cover plantings providing contrast in texture, color and form, grouped in masses are encouraged. FACE OF BLDG. ~ LARGER SHRUBS CLOSE TO BLDG. SMALLER SHRUBS FIGURE NO. 17 CONCEPTUAL PLANT MATERIAL MASSING ADJACENT TO BUILDINGS (ALONG PUBLIC RIGHT-OF-WAY OR MAIN THOROUGH FARES) November 7, 1997 Page 41 Bay West Cove Specific Plan South San Francisco, California $.2 Landscape Design 3.2.4 Plant Material List Botanical Name Trees Affoutus unedo Archontophoenix cunninghamiana Eucalyptus ficifolia Eucalyptus rudis Eucalyptus camaldulensis Frn.xinus oxyclupa 'Raywood' Fraxinus uhdei Met~osideros cxcelsus M¢lnleuca leucadendron Myoporum laetum Prunus bleriana Schinus terebinthifolus Schinus molie =Trachycarpus fortunei Tristania conferta Washingtonia filifera Shrubs Ceanothus 'Condra' Heteromeles arbutifolia £scallonia laevis Escallonia exoniensis 'Compacta' Limonium perezeii Myrica califomica Phormium tenax 'Dazzler' Rhaphiolepis indica 'Springtime' Groundcover Aretostaphylos uva-ursi 'Carmel Sur' Ceanothus gloriosus ~mily Brown' Ceanothus gloriosu$ 'Anchor Bay' Coprosma kirkii Gazania 'Moonglow' Scaevola Tudgrass Vines Hardenbergia violacea Type E=Evergreen D=Deciduous P=Palm S=Shrub GC=Groundcover T=Turfgrass Common Name Sueetscape Landscape Zone Setback Zone - - 5 ~ Landscape Interior Zone S~'awberry Tree 15 gal. E 30725' King Palm 24" box P 50'/15' Red Flowering Gum 15 gal. E 35'/25' SwampGum 15gal. E 40'/30' Red River Gum 15 gal. E 80'/40' Raywood Ash 15 gal. D 25'/20' Evergreen Ash 15 gal. E 35./30' New Zealand Christmas Tree 15 gal. E 30'/25' Cajeput Tree 15 gal. E 30'/25' NCN 15 gal. E 30'/20' BirdseyePlum 15gal. D 25715' Brazilian Pepper Tree 15 gal. E 30'/30' California Pepper Tree 15 gal. E 35'/35' Windmill Palm 24" box P 25'/20' Brisbane Box 15 gal. E 35'125' California Fan Palm 24" box P 50'/20' NCN Toyon Pink Escallonia NCN Sea Lavender Wax Myrtle New Zealand Flax India Hawthorne 5 gal. S 5'/7' · · · · 5 gal. S 15./15' * · 5gal. S 10'/8' * .... 5 gal. S 4'/4' · .... 5 gal. S 2'/2' · · · · 5 gal. S 10'/8' * · 5 gal. S Y/Y * · * * 5 gal. S 4./4' · Bearberry Carmel Creeper Point Reyes Ceanothus NCN Gazania Mauve Clusters Tall Fescue 1 gal. GC 6"/12' * · l gal. GC 3'/10' * * * l gal. GC 12"/Y * · flats GC 6"18' * * · * flats GC 6"/2' · .... flats GC 4"/Y * · sod T .... * * · * * * {Lilac Vine I Igal. lv l .... I I I - I I · I C=Conifer V=Vines/Climbing t: Callander Associates November 7, 1997 Page 42 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design 3.2.5 Amenities Pedestrian plazas or courtyards are provided to promote the proposed pedestrian aspect of the project. Centralized outdoor lunch patios/courtyards are required at each development site. Seating, shade and other amenities are also necessary. These areas will play an important part in establishing Bay West Cove as a quality working and shopping environment. Textured (Iow-profile) pavement in the form brick/stone/tile pavers and/or exposed aggregate concrete are encouraged to help define pedestrian from vehicular areas. Plazas/courtyards shall be separated from loading docks. Placement shall occur to encourage employee and public use. POTS WITH R.OWERING SHFlUBS AND ANNI. I~,J. COLOR BUILDING ENTRANCES BUILDING VARIES MAX. I[~'=~-~-' "~' BENCH, 1YP. It~ TRASH RECEPTACLE. I PEDESTRIAN WALKWAYS FIGURE NO. 18 SITE AMENITIES & ACCENT PAVING November 7, 1997 Page 43 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.5 Amenities -continued Public access along the bay front is required. Site amenities may include a bicycle path, seating/viewing areas, landscape planting, marsh/wetland establishment, and interpretive signage. Bay Trail Improvements will be installed by Bay West Cove L.ToD. in conjunction with the approval of the Development Plan. VIEW PLAZAS (2 LOCATIONS) REFER TO FIGURE NO. 20 FIGURE NO. 19 PLAZA/BAY PATH November 7, 1997 Page 44 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.5 Amenities -continued COMPOSED MOUNDED GRANITE PATH P~NTING AREA WETLAND SLOPE (~.: 1 ) WITH ~I~H'~-I.~N:I'iNGS . fz~/' INTERPRETIVE SIGN. TYP '_~"~. BOLLARDi TYP. .SALT MARSH AND V1EW PLAZA ORNAMENTAL ' NATIVE PLANTINGS J J PLANTING PATH ,~'TURF~, .PARKING ' .STRIP ~ ,~LT MARSH AND NATIVE PLANTINGS ,PATH~STRII~'IURF . P,~.~NG. FIGURE NO. 20 BAY PATH/PLAN/ENLARGED SECTIONS November 7, 1997 Page 45 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.5 Amenities -continued REFERTO FIGURE NO. 20 ~ = FOR ENLARGED SECTIONS ~ · ,,o,%~=,..' ,,~.,~,?_;~ ,,,~ SECTION BB: LANDSCAPE BUFFER ADIACE,~.'T TO SHORELINE !EFER TO FIGURE NO. 20 -~R ENLARGED SECTIONS q~"~EL. *10 PROPOSED SECTION AA: VIEWING PLAZA / LANDSCAPE BUFFER AROUND SLOT FIGURE NO. 21 BAY PATH/SECTIONS November 7, 1997 Page 46 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.5 Amenities - continued e0 All ground-mounted utilities (i.e. air conditioning, vaults, etc.) and irrigation equipment (i.e. backflow prevention devices, controller enclosures, etc.) will be screened with massing of shrubs, trees or some other form of screening (i.e. Iow wall, etc.). FIGURE NO. 22A PLANT MATERIAL SCREENING November 7, 1997 Page 47 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.5 Amenities- continued Cart storage areas shall be located conveniently throughout the parking area. ~ LANDSCAPE ISLAND IN PARKING FIELD ~CONCR~ERAMP SHOPPING CART I SLOPE I 4 PLAN LANDSCA~NG LANDSCAPI~ SCREENING ! 'T FIGURE NO. 22B SHOPPING CART SCREENING November 7, 1997 Page 48 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 52' 25' SIGNAGE MAIN DRIVE OYSTER POINT (HOTEL/RETAIL ENTRANCE) NOTE: THIS DESIGN IS TYPICAL OF THE GATEWAY ENTRANCE FIGURE NO. 23 MAIN ENTRANCE November 7, 1997 Page 49 Bay West Cove Specific Plan South San Francisco, California 3.2 Landscape Design - continued 3.2.6 Landscape Irrigation a. All irrigation systems shall be fully automatic. Low-volume irrigation equipment is encouraged for all planted areas within the individual sites and shall be completely automatic. Sprinkler overthrow onto walks, buildings, windows, plaza areas, etc. will not be allowed. Irrigation hardware shall be placed out of sight and within the landscape areas. e0 Irrigation controllers shall be located within the buildings wherever possible. Irrigation controllers which cannot be located within the building interior shall be installed in locking, vandal resistant cabinets, placed out of sight and within the landscape areas. Pop-up sprinkler heads shall be used in all planting areas for safety and maintenance concerns. Trees shall receive a separate bubbler irrigation system. 3.2.7 Landscape Maintenance All planted and paved areas of each parcel shall be at all times maintained in a fully and well-kept landscape condition. Plantings shall be kept in a healthy growing condition free of weeds and debris. The owner of each parcel shall, at all times, keep and properly maintain the entire premises in a safe, clean, condition and in a good state of repair, complying in a!l respects with governmental, health,fire, and police requirements and regulations. Sites that are not improved or built upon, shall be maintained at all times in a clean and neat condition by the property owner, by removal of weeds, grasses, brush, and debris. Bay West Cove Management has the right to perform the necessary maintenance and charge the individual tenant or property owner as required should the necessary maintenance not be performed within thirty (30) days of written notification by management. November 7, 1997 Page 50 Bay West Cove Specific Plan South San Francisco, California 4. ARCHITECTURE GUIDELINES These guidelines are to be used in conjunction with the East of 101 Area Plan. They do not supersede, but complement, said Guidelines. However, to the extent these Guidelines are more restrictive than the East of 101 Area Plan, they shall prevail. 4.1 Objectives To promote commercial development while enhancing the physical environment of the community. To ensure land use compatibility between parcels within the project. To ensure land use compatibility of the project with land uses on adjacent property. To set the tone for the entry way into the East 101 area in terms of quality and appearance. 4.2 Standards 4.2.1 Minimization of apparent building mass is important to the preservation of the development, and should be encouraged through these guidelines. These guidelines encourage modulation of facades, addition of recessed or protruding balconies, provision of layered facade elements, effective use of color, landscape and other means. As a general rule, building massing is to be pedestrian in scale and not excessively awesome, bulky, overbearing or monolithic. Primary masses should be set back on the site to avoid cramping the streetscape. FIGURE NO. 24A MASSING November 7, 1997 Page 51 Bay West Cove Specific Plan South San Francisco, California 4.2 Standards - continued: 4.2.2 Form Balancing of sloping roof forms with horizontal and vertical roof elements, such as towers and parapets, will be encouraged. Building forms of simple geometry with sensitive use of sculptural forms, to define and enhance, will be encouraged. Planned offsets to reduce building mass, strengthen entry plazas and establish architectural interest will be stressed. Projecting forms which break up long blank facades, overhangs which add shades and shadows, emphasized horizontal elements will also be encouraged. Hip roof Hip roof without corner Intersecting form Clerestory windows between roof lines LO~ PROFILE, HOR[ZO£1TAL ROOF FOR~'IS ARE RECO~4ENDE D. FIGURE NO. 24B FORM November 7, 1997 Page 52 Bay West Cove Specific Plan South San Francisco, California 4.2 Standards - continued: 4.2.3 Scale Low pedestrian scale is encouraged through the use of Iow profile building facades, stepping building masses and landscaping. Building signage and other elements which are constructed near pedestrian level will create a pleasant, human scale. Diversity of material within the lower zone of a project is encouraged not only to convey quality but to create visual interest for the pedestrian. - ':.. Scale can ct.otc a moo& 3:2 RaHo affords a cornfor~ble sense of enclosure FIGURE NO. 24C SCALE November 7, 1997 Page 53 Bay West Cove Specific Plan South San Francisco, California 4.2 Standards - continued: 4.2.4 Proportion Building proportions should achieve strong building base and a diminishing appearance as the building is visualized against the skyline. 4.2.5 Uniformity Design and materials of all elements within a development should be similar and compatible. 4.2.6 Height The height of a structure is measured as the vertical distance from the highest point of the structure to either the natural grade or the finished grade of the adjacent surfaces, which ever is greater. Additional height for architectural extensions should be allowed within specific height and area limitations, and subject to specific findings through public review. The intent is to allow punctuating accent and focal elements, such as towers. 4.2.7 Facade Elements Colonnades, arches, plazas, arcades and courtyards will be used to create architectural and functional interest. Windows play a critical role in the visual effects of buildings. Guidelines will encourage window design which accentuates the rhythm of the building bays, maximizes pedestrian view of storefronts where appropriate, and provides detail. FIGURE NO. 24D FACADE ELEMENTS November 7, 1997 Page 54 Bay West Cove Specific Plan South San Francisco, California 4.2 Standards - continued: 4.2.8 Materials Sensitive choice of building materials is essential to the character of the buildings within the center area. Primary surfaces should be finished in materials which convey the character of natural materials and small modular scale, such as wood, stone, brick and plaster. Prefabricated materials of larger scale, such as metal panels, should be discouraged except in areas of limited visibility. Materials should be simple and easy to maintain. All structures erected within the project, with the exception of trim and minor architectural features, shall be constructed of masonry, concrete, stucco, glass, steel, or other materials of a similar high quality nature. 4.2.9 Color Building color schemes will be non-complex, light in shades and consist of simple accents. An effective and reasonable approach to regulating color should guard against clearly disruptive effects, rather than try to arrange a particular effect. Appropriate strategies would include: require most ground floor glazing to be clear. encourage neutral colors for primary walls. allow a wider spectrum of accent colors. 4.2.10 All sides of buildings that are visible from a streets or public area shall be detailed and treated with relief elements and variation in plane. Architectural elements used for providing relief may include awning projections, trellises, built in planters, integrated plazas, expression of structural elements (i.e. beams, columns, etc.), changes in material and textures or elements/treatments that create patterns of shade shadow. 4.2.11 Exterior walls shall be painted or treated in a manner that is suitable for the exterior construction material. 4.2.12 Building placement shall be designed in such a way to create opportunities for plazas (outdoor gathering areas) or other landscaped open spaces and encourage defined spaciously enclosed open space on the same site or adjoining sites. Building orientation should include consideration of wind protection for site activities. 4.2.13 Architectural style is intended to be complimentary throughout the overall Bay West Cove project. Varying architectural styles maybe proposed as long as they do not create visual conflict. November 7, 1997 Page 55 Bay West Cove Specific Plan South San Francisco, California 4.2 Standards o continued 4.2.14 Colonnades or arcades and other covered walkways or structures that provide protection to pedestrian spaces from wind and rain shall be utilized whenever possible. COV~EI~D WAL~'WA¥ FIGURE NO. 25A TYPICAL CANOPY SECTION FIGURE NO. 251) TYPICAL CANOPY SECTION November 7, 1997 Page 56 Bay West Cove Specific Plan South San Francisco, California 4.2 Standards - continued 4.2.15 Apparent building mass should be reduced through sensitive articulation and surface treatment of exterior walls. Long, inarticulate, walls should be avoided. Staggered or layered vertical articulation reduces the visual impact and helps to provide an interesting architectural impression. 4.2.16 Building entries shall provide protection from Wind and rain. 4.2.17 Sensitive arrangement and proportion of exterior window openings, exterior fascia treatment, and building accent areas will help to relieve the appearance of large expansive exterior walls. 4.2.18 At street level, pedestrian scale building materials, and building details shall be required where appropriate. 4.2.19 All roof-mounted equipment shall be screened from view by parapets or other building forms. ROOF MOUNTED EQUIPMENT PARAPET SCREENING ! ! BLDG. A. UNE OF SIGHT BLDG. B FIGURE NO. 26 ROOF MOUNTED EQUIPMENT SCREENING November 7, 1997 Page 57 Bay West Cove Specific Plan South San Francisco, California 4.2 Standards - continued 4.2.20 The use of reflective glass shall be subject to approval by the city Design Review Committee. Any reflective glass approved will be soft and non-mirrored glass. 4.2.21 Design consideration should be given to: a. Solar orientation and climate. b. Orientation toward major streets and thoroughfares. c. Vehicular and pedestrian flows. d. Expressions of the individual character of each business. e. Energy conservation through building design. Building entrances shall be well articulated and project a formal entry statement through a variation of building form, decorative pedestrian plazas and landscape areas. Complementary colors, materials and textures in conjunction with dynamic building forms are encouraged. 4.2.22 Service areas and loading facilities shall be orientated to obscure lines of sight from Oyster Point Boulevard. Screening walls and landscaping shall be utilized to further conceal these areas, 4.2.23 Outdoor sales and storage areas shall be located in a manor as to reduce visual impact from Oyster Point Boulevard, maintain required fire access clearances, away from building entrances, out of main drive aisles and minimize impact to parking circulation patterns. When possible outdoor sales and storage areas should be located to the sides or rears of buildings 4.2.24 Style The architectural theme of the Center will integrate, to the greatest extent possible, the character of the surrounding areas. The use of traditional/historic materials, textures and colors will be combined with more contemporary motifs and detailing. The various buildings of the Center should relate to one another and to the larger community of the area. 4.3 Material Palette Building material and color palettes shall be as approved by the applicable city body. Building colors may include earth tones and appropriate pastels. Bright colors and simple primary colors should be November 7, 1997 Page 58 Bay West Cove Specific Plan South San Francisco, California avoided, except as accents. Within a limited range, building surfaces should incorporate more than one color. 4.4 Graphics, Signage A Master Sign Program shall be submitted to the applicable city body for review and approval, prior to issuance of a building permit. The sign program will include temporary signage, permanent signage, review and approval process. Refer to the following Master Sign Program for Bay West Cove. November 7, 1997 Page 59 Bay West Cove Specific Plan South San Francisco, California SIGN CRITERIA FOR BAY WEST COVE SOUTH SAN FRANCISCO, CALIFORNIA PREPARED FOR: BAY WEST COVE, LTD. 600 TOWNSEND STREET SAN FRANCISCO, CALIFORNIA (415)552-7700 PREPARED BY ARCHITECTS November 7, 1997 SIGN PROGRAM 94375.04 November 7, 1997 Page 60 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Program A. Introduction: These guidelines have been established for the purpose of assuring a functional, coordinated and visually attractive sign program for the mutual benefit of all tenants. Conformance will be stdctly enforced. Upon demand by the landlord, or the City, any installed non-conforming or unapproved sign must be brought into conformance or removed at the non-conforming tenant's expense. Exceptions to these standards shall be reviewed by the Landlord. Landlord will retain full rights of approval of any sign used in the center. The project sign consultant is to interpret these guidelines, but he is not empowered to authorize any departure from them without written approval of the City and the Landlord. B. Scope: The Bay West Cove Sign Program sets forth requirements for all signs attached to a tenant frontage or building, Including Tenant Identification signs, Secondary Identification signs, entry signs, window signs, under canopy signs, standards for freestanding signs and center identification signs. C. Definitions: 1. Tenant Identification Sign: ' A tenant name, logotype and/or logo, displayed on a sign fascia, storefront or building wall. Tenant Identification Signs may also include an ancillary graphic element where necessary to reinforce the tenant's identification. Such an ancillary graphic element shall be no more than 80% of the length and no more than 50% of the height of the primary logotype or logo. An ancillary graphic element shall be included in the calculation of sign area and sign height. Sign copy shall not include the product sold, except for logo types or Iogos which include a product name, or as allowed at Sections D. 1 .b and D.4. Logotype: A standardized representation of a company or business, comprised of a particular typeface, graphic layout and color(s), which is consistently used on signs, letterhead, business cards et al. November 7, 1997 Page 61 Bay West Cove Specific Plan South San Francisco, California C. Definitions - continued: Logo: A distinctive trademark recognizable to the public as a symbol of an established company or business. A logo is usually displayed in conjunction with a logotype. Secondary Identification Sign: A sign identifying a generic type of merchandise or service, such as a pharmacy, garden center or bakery. Food Sales anchor tenants, General Merchandise, Hotel/Motel and Entertainment anchor tenants only are allowed secondary identification signs as set forth under Sign Allowances below. Fascia Sign: A sign shall be considered to be a fascia sign if the sign would fall without support from the building or improvement. Additionally, these signs shall be mounted flush against or parallel to the surface of the building facade. These signs typically consist of either signage enclosed within a cabinet box or individual letters. Under Canopy Sign/Blade Sign: A pedestrian-scale sign mounted perpendicular to the storefront at the main entry to a major tenant or shop tenant space. An under canopy sign/blade sign is not included as part of the maximum number of signs or maximum allowable square feet of sign area permitted for a tenant space. Awning Sign: A tenant name, logotype or logo which is displayed on an awning attached to a tenant space. Total Sign Area: Total area of the sign shall be all of the area encompassed within a single continuous rectilinear-perimeter of not more than ten (10) straight lines, enclosing the extreme limits of the message surface (and in no case passing through or between any segments of the message surface) and including any color, material, or graphic which is integrated therein which differentiates the message from the background against which it is placed, and the face of any frame. Anchor Tenant: A tenant occupying a tenant space of 50,000 square feet or more. Food Sales anchor tenants sell primarily food goods, as well as non food items commonly found in "warehouse" style grocery stores. General Merchandise anchor tenants sell a variety of goods such as furniture, furnishings, household appliances, automotive accessories, sporting goods, apparel, computers and office equipment, and garden supplies. November 7, 1997 Page 62 Bay West Cove Specific Plan South San Francisco, California C. Definitions - continued: Entertainment anchor tenants - tenant providing movie theaters and concession stands. Hotel/Motel anchor tenants - tenant providing overnight accommodations. Auto sales anchor tenants - tenant providing new and used auto sales and servicing. 10. Major Tenant: A tenant (except a pad tenant) occupying a tenant space at least 15,000 square feet but less than 49,999 square feet. 11. Specialty Tenant: A tenant occupying a tenant space at least 5,000 square feet but less than 14,999 square feet. 12. Shop Tenant: A tenant occupying a tenant space, within a shops building, of 5,000 square feet or less. 13. Pad Tenant: A tenant occupying a freestanding building. 14. Maximum Fascia Sign Horizontal Dimension: The maximum allowable horizontal dimension for a fascia sign shall be 80% of the length of the tenant frontage or the fascia. See Exhibit A-1 and A-2. 15. Maximum Fascia Sign Vertical Dimension: The maximum allowable vertical dimension for a sign varies depending on the tenant category as set forth under the sign allowances below. 16. Maximum Logo Size: When a logo and logotype are displayed on the same tenant frontage, the overall height of the logo shall be no more than 150% of the overall height of the logotype, and the total sign area of the logo shall be no more than 33% of the total sign area of the logotype. 17. Window Signs: A sign applied directly onto a window or internal to the window within twelve (12) inches of the window and visible from the public right-of-way. 18. Building Frontage: The length of any given side of building in which a sign is proposed. D. General Requirements: Each tenant shall submit or cause to be submitted, scaled drawings to the Landlord for approval, before fabrication, at least five (5) copies of detailed drawings including all lettering and/or graphics, November 7, 1997 Page 63 Bay West Cove Specific Plan South San Francisco, California D. General Requirements - continued: one (1) in full color, Send to: a. Address of sign location. b. Name and phone number of tenant. c. Name, address and phone number of contractor or erector. d. Site plan showing location of signs. e. Elevation showing location on building or other structure including heights of signs and any projection from building. f. Elevation of sign showing dimensions and materials. g. Construction details of typical sections for all applicable signs. In some cases, the Building Inspector will require that the details are accompanied by the signature of a California licensed engineer or architect. h. Sign valuation and, for electric signs, the number of transformers. Tenant shall submit a sign drawing approved by the Landlord to the appropriate City and County authority for approval pdor to the start of any sign construction or fabrication. All permits for signs and their installations shall be obtained by the tenant or its representative at its expense. Tenant shall be responsible for the fulfillment of all requirements and specifications. The location of the signs shall be per the accompanying design criteria. The Tenant shall verify its sign location and size with the Landlord and Architect in writing prior to fabrication. The Tenant shall pay for all signs, their installation (including final connection, transformers and all other labor and materials) and maintenance. The maximum allocated sign area for the aggregate of all permanent signs (except as exempted pursuant to the City Code) shall be as noted. It is the responsibility of the Tenant's sign company to verify all conduit and transformer locations and service prior to fabrication. 10. Except as permitted herein any illuminated sign or lighting device shall employ only lights emitting a light of constant intensity, and no sign shall be illuminated by or contain flashing, intermittent, rotating November 7. 1997 Page 64 Bay West Cove Specific Plan South San Francisco, California D. General Requirements - continued: or moving lighting or lights. In no event shall an illuminated sign or light device be placed or so directed upon a public street, highway, sidewalk or adjacent premises so as to cause glare or reflection that may constitute a traffic hazard or nuisance. 11. No sign shall be constructed until approved permits from the City of South San Francisco Planning and Building and Safety Departments are received. Specifications and Quality Standards: All tenant identification signs and secondary identification signs shall consist of face-illuminated, individual dimensional letter forms and/or symbols (or an assembly of dimensional letter forms if the tenant's logotype is script-style letters). All letter/symbol faces shall be translucent acrylic with integral color; all returns shall be coated aluminum with a 'trim cap" type retainer detail or back lit style individual letters. If the tenant's logotype and/or symbol is a single color, the returns shall match the letter faces unless the tenant has an established corporate sign program which specifies a different return color. If the tenant's logotype and/or symbol is more than one color, all returns shall be a single color. Logos are only allowed on the building elevations that contain a permitted sign. The channel letters shall be constructed of metal or aluminum and fastened to the wall or fascia in an approved manner. All metal shall receive a minimum of two (2) coats of primer and one (1) coat of finish. Metal sheet seam joints shall be by electric weld only. No painted wall signs or awning signs are allowed. Cabinet signs are only allowed for ancillary graphic elements approved under Section D. 1 .b. Signs shall have a maximum of two rows of copy. All fascia signs shall be centered left to right on the fascia or tenant frontage, and generally centered top to bottom between fascia reveals. (The vertical position will vary depending on the configuration of the sign and the locations of the reveals on the sign fascia; Exhibit 'A'. Proposed sign locations for tenant logo types and/or symbols with unusual configurations shall be submitted to the Landlord for review prior to the filing of an application with the city. November 7, 1997 Page 65 Bay West Cove Specific Plan South San Francisco, California Specifications and Quality Standards: - continued: Power will be provided from the tenant's electrical panel to a junction box at all sign locations. Power hookup shall be by tenant. Time clock shall be provided by tenant to turn signage on and off. All electrical signs shall bear the UL label (not visible to public), and their installation shall comply with all local building and electrical codes. Electrical service to sign shall be paid for by tenant. All penetrations of the building structure required for sign installation shall be neatly sealed in a water-tight condition. Tenant's sign contractor shall repair any damage to Landlord's building caused by his work. Damage to structure that is not repaired by the sign contractor shall become the tenant's responsibility to correct. Tenant shall be fully responsible for the work of tenant's sign contractor and shall indemnify, defend and hold the Owner harmless from damages or liabilities. All lettering shall be restricted to the "net sign area". No projection above or below the "net sign area" will be permitted (except as otherwise approved in writing). See accompanying design criteria for specific information. All bolts, fastenings, clips, etc., shall be painted out to match the adjacent surface. 10. No signmaker's label or other identification shall be permitted on the exposed surface of the sign, except for those required by local ordinance, and these shall be placed in an inconspicuous location. 11. No exposed conduit, tubing light source, or raceways shall be permitted. 12. All conductors, transformers, and other equipment shall be concealed. 13. No flashing, moving, or audible signs shall be permitted. 14. No signs of any sort shall be permitted on building roofs. 15. When any sign is removed, either for replacement or on termination of the lease, the tenant shall leave the building exterior in good condition, normal wear and tear excepted. Any holes caused by the removal of said sign shall be filled and November 7, 1997 Page 66 Bay West Cove Specific Plan South San Francisco, California Specifications and Quality Standards: - continued: painted to match. 16. It shall be the responsibility of the tenant to ensure that all signs are removed from a tenant space within ten (10) days of its being vacated. 17. Banners or theme flags are permitted for special events only and shall be subject to Landlord approval and the approval of the City of South San Francisco. 18. Temporary window signage for special or seasonal sales shall be subject to Landlord approval and shall be limited to a maximum of twenty-five percent (25%) of the window area per elevation. All such signs shall be professionally prepared. 19. Tenant shall verify their sign location and size with Landlord prior to fabrication. 20. Signs which vary from this sign criteria must first be approved by Landlord and the respective City and County authorities. 21. Tenant is required to maintain their signs in a first class condition and replace defective lights, components, etc., as necessary. 22. Tenant shall display only its' established trade name of their basic product name, e.g. 'Uohn's Jeans", or combination thereof. 23. Halo lighting shall be 60 milli-amp neon lamps installed and labeled in accordance with the "National Board of Fire Underwriters Specification". 24. All letters to have service access to lamps, ballasts and wiring. Sign Allowances for Anchor Tenants: Anchor tenants occupying a tenant space of 50,000 square feet or more: The below outlined specifications should be considered design parameters for the commercial center and do not necessarily conform to the City of South San Francisco Zoning Ordinance. Applicant will require written approval from landlord prior to submittal of signage proposal to the City. The total sign area shall not exceed 1.5 square foot of sign per lineal foot of the principal tenant frontage (not to exceed 50% November 7, 1997 Page 67 Bay West Cove Specific Plan South San Francisco, California Sign Allowances for Anchor Tenants - continued: of building frontage). Corner tenants are also allowed 1.0 square foot of sign per lineal foot on the second tenant frontage (not to exceed 50% of building frontage). bJ Signs identifying a generic type of merchandise or service, such as a pharmacy, auto maintenance, garden center or bakery. Food Sales anchor tenants, General Merchandise, Auto Sales, Hotel/Motel and Entertainment anchor tenants only are allowed secondary identification signs. c. The maximum allowable letter height for any sign shall be 8'0". dj A ground level occupancy with more than (1) occupancy frontage may have one (1) attached sign on each occupancy frontage, not to exceed three (3) frontages. G. Sign Allowances for Major Tenants: Major tenants occupying a tenant space greater than 15,000 square feet but less than 50,000 square feet. The above outlined specifications should be considered design parameters for the commercial center and do not necessarily conform to the City of South San Francisco Zoning Ordinance. Applicant will require written approval from landlord prior to -submittal of signage proposal to the City. The total sign area shall not exceed 1.5 square foot of sign per lineal foot of the principal tenant frontage (not to exceed 50% of building frontage). Corner tenants are also allowed 1.0 square foot of sign per lineal foot on the second tenant frontage (not to exceed 50% of building frontage). The total number of signs allowed shall be one logotype and one Iago on the principal building elevation, and, for corner tenants only, one logotype and one Iago on the second elevation. c. The maximum allowable letter height shall be 6'0". H. Sign Allowances for Specialty Tenants: The total sign area shall not exceed 1.5 square foot of sign per lineal foot of storefront except that the minimum total area allowed shall be 16 square feet (not to exceed 80% of building frontage). November 7, 1997 Page 68 Bay West Cove Specific Plan South San Francisco, California H. Sign Allowances for Specialty Tenants - continued: The total number of signs allowed shall be one logotype and one logo unless Landlord has identified tenant as a multi occupancy frontage tenant. The maximum allowable letter height shall be 3'0", except that letters starting words may have a maximum height of 4'0". The above outlined specifications should be considered design parameters for the commercial center and do not necessarily conform to the City of South San Francisco Zoning Ordinance. Applicant will require written approval from landlord prior to submittal of signage proposal to the City. Sign Allowances for Shop Tenants: The total sign area shall not exceed 1.5 square foot of sign per lineal foot of storefront except that the minimum total area allowed shall be 16 square feet (not to exceed 80% of building frontage). The total number of signs allowed shall be one logotype and one logo unless Landlord has identified tenant as a multi occupancy frontage tenant. The maximum allowable letter height shall be 3'0", except that letters starting words may have a maximum height of 4'0". Sign Allowances for Single Tenant Pad Buildings: The total sign area shall not exceed 1.5 square foot of sign per lineal foot of storefront except that the minimum total area allowed shall be 16 square feet (not to exceed 80% of building frontage). This shall not preclude a tenant from submitting a sign of less than 16 square feet if the tenant feels this smaller sign is appropriate. e A ground level occupancy with more than (1) occupancy frontage may have one (1) attached sign on each occupancy frontage, not to exceed three (3) frontages. The maximum allowable letter height shall be 3'0", except that letters starting words may have a maximum height of 4'0". K. Sign Allowances for Multi-tenant Pad Buildings: The total sign area shall not exceed 1.5 square foot of sign per lineal foot on one building elevation, and 1.5 square foot of sign per lineal foot on a second elevation, except that the minimum total area allowed on November 7, 1997 Page 69 Bay West Cove Specific Plan South San Francisco, California K. Sign Allowances for Multi-tenant Pad Buildings - continued: either of these elevations shall be 16 square feet (not to exceed 80% of building frontage). This shall not preclude a tenant from submitting a sign of less than 16 square feet if the tenant feels this smaller sign is appropriate. A ground level occupancy with more than (1) occupancy frontage may have one (1) attached sign on each occupancy frontage, not to exceed three (3) frontages. The maximum allowable letter height shall be 3'0", except that one letter may have a maximum height of 4'0". Sign Allowances for Auto Sales Tenant: Main Building Identification - 6' channel letters and 8'-9" logo, internally illuminated (337 square feet) and mounted on two building facades. See exhibit AN-1 and AN-3. Secondary Building Identification - 5' channel letters and 7'-3" logo, internally illuminated (233 square feet) and mounted on one building facade. See exhibit AN-1 and AN-3. Service Area Building Identification - 4'-7 1/2" x 22' S/F cabinet and four 15"x 48" aluminum panels, internally illuminated (122 square feet) and mounted on one building facade. Internal directional signage will be reviewed by the City on an individual tenant basis. M. Building Address Signs: 1. Each building shall have address numbers posted in a conspicuous place. Numbers should be 12" in height and either internally or externally illuminated. Requirements for Entry Signs: Storefront Entry: Each tenant is permitted to display business hours, an emergency telephone number or similar information at each public entry as shown and specified in Exhibit B. Service/Receiving Entry: Each tenant shall display the tenant name, address and emergency telephone number on the service door as shown and specified at Exhibit B. Letter Height: The maximum letter height for entry signs shall be six inches. November 7, 1997 Page 70 Bay West Cove Specific Plan South San Francisco, California O. Requirements for Window Signs: All window signs shall be restricted to a maximum of twenty-five (25) percent of the window area on the frontage for the proposed sign(s), subject to the approval of the Planning Department. Window signs include internal displays of stock-in-trade if the display is located within twelve (12) Inches of a window and is visible from the public right-of- way. Requirements for Under Canopy Signs: One under canopy sign/blade sign is allowed at the main entry to a tenant space. An under canopy sign shall be provided and installed by the tenant, using a standardized mounting bracket. Contact Landlord's sign contractor for mounting bracket specifications. The under canopy sign shall be a single rectangular shape which displays the tenant name only; the maximum allowable size shall be 6.0 square feet. 3. The minimum clearance beneath the sign shall be 8'6". 4. All signs shall be non-illuminated. The sign is to be fabricated from a durable material such as MDO plywood, high density foam or aluminum sheet and finished with a waterproof and/or corrosion-resistant coating as required. All signs are to have flat surfaces (i.e. no sandblasting or raised letter forms). The tenant shall submit a graphic layout to scale, shop drawings, and specifications for materials, finish and color to the sign consultant for approval prior to fabrication and installation. 7. A sign permit is required for a under canopy sign. Freestanding Restaurant Signs: This provision includes menu signs for drive-through restaurants. Such signs are intended to be viewed by patrons, and shall not be designed to advertise the restaurant along street right-of-way. Such signs shall be a maximum of six feet (6') in height, and Sign Copy Area shall be a maximum of sixteen (16) square feet. Restaurant menus located at main entry to the restaurant, not exceeding three (3) square feet of Sign Area, placed at a maximum height of six feet (6'). Such signs shall be self illuminated, and may only be lit by external lighting, and shall be designed for view by pedestrians only. November 7, 1997 Page 71 Bay West Cove Specific Plan South San Francisco, California Se No freestanding sign shall cause a visual obstruction within a driveway corner cut-off. Center Identification Signs for Hotel and Commercial Tenants: 1. Subject to City and County regulations. Center Identification Signs shall be located on each side of the main entry intersection located at the arterial road of the commercial center and Oyster Point Boulevard. Monument signs at entrances shall include the range of site addresses typically accessed by that driveway entrance and shall be illuminated. 4. Refer to Exhibit C. Center Identification Signs to Auto Sales: 1. Subject to City and County regulations. Center Identification Signs shall be located on each side of the main entry intersection located at the auto sales entrance (westerly entrance off Oyster Point Boulevard) and Oyster Point Boulevard. Monument signs at entrances shall include the range of site addresses typically accessed by that driveway entrance and shall be illuminated. 4. Refer to Exhibit D. Freestanding Monument Signs: Subject to City and County regulations, for street tenant and single tenant buildings, such tenants may be allowed signage on two (2) sided monument sign not to exceed a hundred (100) square feet per sign face and dimensions of twelve (12) feet high and ten (10) feet long. The attached Planned Signage Program provides accommodation for one freestanding monument sign for each freestanding tenant pad building (i.e. Hotel/Motel, Restaurant, etc.). These signs would be located at strategic locations along the hotel / commercial center arterial road. Monument signs at entrances shall include the range of site addresses typically accessed by that driveway entrance and shall be illuminated. 5. Refer to Exhibit E. November 7, 1997 Page 72 -. Bay West Cove Specific Plan South San Francisco, California U. Freestanding Pylon Signs: Subject to City and County regulations, for street tenant and single tenant buildings, such tenants may be allowed signage on two (2) sided pylon sign not to exceed a thousand (1000) square feet per sign face and dimensions of seventy five (75'-0'~) feet high and thirty two (32'-0'~ feet wide. The attached Planned Signage Program provides accommodation for one freestanding pylon sign for the purpose of identifying the commercial center and seven (7) of the centePs tenants. The dimensional parameters of the proposed pylon sign are subject to modification upon completion of a sight-line study. City will be provided information outlining existing grades, pylon sign location and future freeway overpass to evaluate appropriate sizing of sign. Study will be prepared prior to any construction of the proposed pylon sign. 4. Refer to Exhibit F.. V. Prohibited Signs: Signs Constituting a Traffic Hazard: No person shall install, maintain, or cause to be installed or maintained any sign which simulates or imitates in size, color, lettering or design any traffic sign or signal, or which makes use of the words "STOP". "LOOt~', "DANGER", or any other words, phrases, symbols, or characters in such a manner to interfere with, mislead or confuse traffic. Immoral or Unlawful Advertising: It shall be unlawful for any person to exhibit, post or display cause to be exhibited, posted or displayed upon any sign, anything of an obscene, indecent, or immoral nature or unlawful activity. Signs on Doors, Windows or Fire Escapes: No window signs will be permitted except as noted herein. No sign shall be installed, relocated, or maintained so as to prevent free ingress to or egress from any door. No sign of any kind shall be attached to a stand pipe except those signs as required by code or ordinance. Animated, Audible or Moving Signs: Signs consisting of any moving, swinging, rotating, flashing, blinking, scintillating, fluctuating or otherwise animated lights, are prohibited. Off-Premise Signs: Any signs, other than a directional sign, installed for the purpose of advertising a project, event, person or subject not November 7, 1997 Page 73 Bay West Cove Specific Plan South San Francisco, California V. Prohibited Signs - continued: related to the premises upon which said sign is located, is prohibited. e Vehicle Signs: Signs on or affixed to trucks, automobiles, trailers, or other vehicles which advertise, identify, or provide direction to a use or activity not related to its lawful making of deliveries of sales or merchandise or rendering of services from such vehicles, is prohibited. Ught Bulb Strings and Exposed Tubing: External displays, other than temporary decorative holiday lighting, which consist of unshielded light bulbs, and open, exposed neon or gaseous light tubing, are prohibited. An exception hereto may be granted by the Landlord when the display is an integral part of the design character of the activity to which it relates. Banners, Pennants, and Balloons Used for Advertising Purposes: Flags, banners, or pennants, or a combination of same, constituting an architectural feature which is an integral part of the design character of a project may be permitted subject to Landlord and City approval. Signs in Proximity to Utility Lines: Signs which have less horizontal or vertical clearance from authorized communication or energized electrical power lines than that prescribed by the laws of the State of California are prohibited. 10. "Can" Type Signs: All signs on the faces of buildings are to be of individual channel letters. "Can" type signs will be prohibited. W. Special Event Signage/Exempted Signs: The following signs, if not illuminated, are allowed with permit required: Signage which does not meet the criteria established in the guidelines, may be approved for a period not to exceed thirty (30) days per calendar year as a means of publicizing special events such as "grand opening" or "inventory sale". This signage must be approved by the Landlord and City prior to installation. The City Building Department shall approve the method and support and attachment of such sign. Temporary signs such as "construction" or "for lease" signs shall be permitted, subject to Landlord and City review. Construction signs shall not exceed four hundred (400) sq.fl.; be not more than twenty-five (25) feet high; and cannot stay up longer than duration of construction. November 7, 1997 Page 74 Bay West Cove Specific Plan South San Francisco, California X. Internal Signage: Internal signage and directional signage will be reviewed at the Precise Plan level. Multi-story Tenants Multi-story tenants will incorporate building identification signs towards upper portion of building, Administration: In the event any conflict of interpretation (between any tenant and the Landlord) regarding these guidelines cannot be satisfactorily resolved, the Landlord decision shall be final and binding upon the tenant. November 7, 1997 Page 75 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sian Program EXHIBIT A- 1 EQ. MAX ALLOWABLE LENGTH (80% LEASEHOLD WIDTH PRINCIPLE FRONTAGE) MAX ALLOWABLE LENGTH (50% LEASEHOLD WIDTH SECONDARY FRONTAGE) · ! Il EQ. LEASEHOLD WIDTH TYPICAL TENANT FRONTAGE ELEVATION ~TAL SIGN AREA NOT TO EXCEED 1 .§ SQUARE FEET )R EACH 1'-0" OF LINEAL BLDG, FRONTAGE),. November 7, 1997 Page 76 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Program EXHIBIT A-2 FI.AT CUT-OUT LE'I-rERS WI HALO ILLUMINATION DIMENSIONAL LE'I-rERS PINNED OFF WALL REVERSE CHANNEL LETTERS W/HALO ILLUMINATION SPECIFICATIONS Fabricated sheet aluminum or.paint-loc steel letter channels, finished in acrylic automotive enamel over primer undercoat. Exterior color is tenants option (subject to approval). Interior shall have white reflective finish. 2. 3/16" clear lexan back, GE S300. o ° 60 milli-amp neon Interior Illumination system. Transformers shall be high power factor. All wiring secondary and primary shall be housed in conduit. All sign letters are to be secured to wall via concealed fasteners. Fasteners are to be stainless steel, or nickel or cadnium plated steel. Letters shall be spaced 1-1/2" from wall. 60 milli-amp high power factor transformer in each letter, all neon electrodes, shall terminate all in transformers or other U.L. approved electrode housings. November 7, 1997 Page 77 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Proaram EXHIBIT B 123 IIIIIIIIIIIIIIII ~ ' IIIIIIIIIIIIIIIII ! IIIIIIIIIIIIIIII IIIIIIIIIIIIIIIII I I I I TENANT ADDRESS NUMBER (CENTERED) SHALL BE QUICK--ALIGN-3 HELVETICA MEDIUM REVERSE DIECUT AS DISTRIBUTED BY BRADY SlGNMARK DIVISION OR EQUIVALENT, 'REFLECTIVE WHITE", NUMBER, SIZE AND HEIGHT AS REQUIRED BY GOVERNING AGENCIES. STOREFRONT DOOR FIXED GLASS (IN STOREFRONT) LOCATION OF TENANT INFORMATION NOT TO EXCEED 144 SQ. IN. TYPICAL TENANT ADDRESS SIGNAGE November 7, 1997 Page 78 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Program EXHIBIT B TENANT NAME .TENANT ADRESS NUMBER DOOR SHOWN IS TYPICAL FOR NON-CUSTOMER TYPE DOOR FOR RECEIVING MERCHANDISE. ETC. OccuRs GENERALLY AT REAR OF CENTER. (VERIFY WITH LEASE PLAN EXACT LOCATIONS FOR INDIVIDUAL TENANTS) TYPICAL TENANT NAME ONLY. (TWO LINES PERMil-~ED, IF REQUIRED.) 6" HIGH WITH 1/2" SPACING BETWEEN LINES. NOTE: ALL LETTERING AND NAUMERALS SHALL BE PAINTED OR ADHESIVE VINYL AS SHOWN IN ELEVATION ABOVE. TYPICAL COLOR SHALL BE WHITE ON DARK DOORS - BLACK ON LIGHT DOORS. TYPICAL LOADING DOOR SlGNAGE November 7, 1997 Page 79 z o OYSTER POINT MAIN DRIVE (HOTEL/RETAIL ENTRANCE)' 0 0 ~ m X I'll o MAIN DRIVE OYSTER POINT ~AUTONATION ENTRANCE~). 13'- 8' \ Itl 0 < ri-! Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Si_an Proaram EXHIBIT E 14'-0" EQ. EQ. L 1= 011 \ 1"-0" 1 '-0" 1 '-0' 2qP .\ November 7, 1997 Page 82 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Program EXHIBIT F 32'-0" 24'-0" A~EA Note: The dimensional parameters of the proposed pylon sign are subject to modification upon completion of a sight-line study. City will be provided information outlining existing grades, pylon sign location and future freeway overpass to evaluate appropriate sizing of sign. Study will be prepared prior to any construction of the proposed pylon sign. November 7, 1997 Page 83 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Program EXHIBIT G CONCEPTUAL SIGNAGE LOCATIONS November 7, 1997 Page 84 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Proaram EXHIBIT AN- 1 22'-0" I I 8' RADIUS --~ CORNERS S/F ELEVATION - WALL MOUNT s/~e"=~'-o" SMALL A/FLEX FRAME ABC EXTRUDED ALUMINUM S/F CABINET - PAINT WHITE INTERNALLY ILLUMINATED WITH 800 M.A. LAMPS SM PANAFLEX GPS FACE - V1'2S22 BLUE BACKGROUND WITH WHITE COPY AND BORDER CLIP - MOUNT TO BUILDING - CENTER ABOVE SERVICE BAYS ELEVATION - SERVICE ENTRY 5/64"= 1'-0" November 7, 1997 Page 85 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Program EXHIBIT AN-2 CHANNEL LETTERS - ANCL INTERNALLY ILLUMINATED LETTERS AND LOGO I 34'-4" 45'-0" 3/16"= 1'-0" 172 SQ. FT. ~ 61 SQ. FT. AND" USA" COPY CHANNEL LETTERS - ANCL 3/16"=1'-0" INTERNALLY ILLUMINATED LE'Fi'ERS AND LOGO November 7, 1997 Page 86 Bay West Cove Specific Plan South San Francisco, California BAY WEST COVE Planned Sign Program EXHIBIT AN-3 ELEVATION ( 6' CHANNEL LETTERS ) 1 "=25'-0" ELEVATION ( 6' CHANNEL LETTERS ) "1 "=25'-0" ELEVATION ( 5' CHANNEL LETTERS ) 1 "=25'-0' November 7, 1997 Page 87 Bay West Cove Specific Plan South San Francisco, California 4.5 Screening of Exterior Electrical Equipment and Transformers 4.5.1 Objective To eliminate the visibility of exterior electrical/mechanical equipment and transformers from view of streets, primary entry drives, floors of image buildings, and common visual and recreational areas, etc. Refer to Figure No. 22A and 26 4.5.2 Standards Transformers that may be visible shall be screened with planting and/or berms or a durable noncombustible enclosure (of a design configuration acceptable to Pacific Gas and Electric Company). bo Transformer enclosures should be designed of durable materials with finishes and colors which are compatible with the adjacent building architecture. Electrical/mechanical equipment shall be located in the interior of a building wherever possible. When interior mounting is not practical, electrical/mechanical equipment shall be located where it is substantially screened from public view. In no case shall exterior equipment be located on the street side of any building. Exterior mounted electrical/mechanical equipment and conduit shall be kept to a minimum. Visible equipment shall be installed in a neat and orderly fashion, and painted to blend with the adjacent building walls. 4.6 Retaining Walls To date it is currently unknown to which extent retaining walls will be incorporated into the development. If retaining walls are to be employed, a design criteria will be established for both structural and esthetic concerns. In most circumstances the City of South San Francisco will require a separate building permit for retaining walls. November 7, 1997 Page 88 Bay West Cove Specific Plan South San Francisco, California 5. OPEN SPACE AREA The Open Space area of the Bay West Cove development is specifically described as the public amenity and wetlands buffer area surrounding the existing slot. 5.1 Pedestrian access A landscaped pedestrian path currently exists within developed projects to the east of the site. This pedestrian path shall continue in a meandering manner along the current boundaries of the present slot, and shall remain in place subsequent to the slot's conversion to a permanent marsh area. See also section 3.2 above. Buildings developed along the open space area shall, if possible, orient tenant activities toward the open space. Pedestrian circulation along building storefronts shall provide distinct and easily accessible connections to the shoreline pedestrian path. Pedestrian access requires a minimum of 48" wide unobstructed paved surface to and along all accessible routes. Items such as signs, meter pedestals, light standards, trash receptacles, etc., shall not encroach on this 48" minimum width. Accessible routes of travel shall conform with the guidelines per California Title 24, Part 2. 5.2 Shoreline / Marsh The existing bulkhead is in a state of disrepair. It shall not be refurbished, but instead covered in the grading operations of creating the new marsh. See section 1.6.6 above. 5.3 Wetlands Mitigation Area A portion of the dedicated open space will be utilized for wetlands mitigation. See section 1.6.6 above. November 7, 1997 Page 89 Bay West Cove Specific Plan South San Francisco, California 6. TRANSPORTATION AND CIRCULATION 6.1 Existing Conditions 6.1.1 Oyster Point Boulevard Improvements Oyster Point Boulevard is under consideration for the addition of lanes in both the east and west direction, requiring dedication of a portion of the existing Bay West Cove site to facilitate realignment north of its present location. Such improvements will accommodate additional vehicular traffic generated by the completed Bay West Cove project. A portion of such improvements shall take place concurrent with the planned Highway 101 / Oyster Point Interchange project. 6.2 On Site Circulation System 6.2.1 Objective To provide access drives located such that vehicular traffic arriving and exiting the site as well as traffic passing continuously on streets, flows at a reasonable level of efficiency. 6.2.2 Ingress and Egress from Oyster Point Boulevard The proposed project will be accessed at three points from Oyster Point Boulevard, adjacent to the south side of the site. The two westerly (main points of access) will be provided with traffic control signals. The easterly entrance will accommodate a right-in and right-out traffic movement. Gateway Access Two ingress and two egress lanes approximately 11 '-9" in width each, with a 5"-0" wide landscape median. A total dive entry width is approximately 52"-0". Refer to Figure No. 23 (similar) Bay West Cove Access Two ingress and two egress lanes approximately 11 "-9" in width each, with a 5'-0" wide landscape median. A total dive entry width is approximately 52"-0". Refer to Figure No. 23 Secondary Access One ingress and one egress lane approximately 15'-0" in width each. A total drive entry width of 30'-0". November 7, 1997 Page 90 Bay West Cove Specific Plan South San Francisco, California 6.2 On Site Circulation System - continued: 6.2.3 Primary Thoroughfares A four lane primary entrance tapering down to a two lane roadway will be provided from the access point at the intersection of Oyster Point Boulevard and the main thoroughfare, continuing northward to provide access to that parcel located on the north side of the proposed marsh area. Landscaped medians shall be provided to provide an entry statement as well as facilitate separation of left turning movements. 6.2.4 Standards a. Access drives shall be coordinated with other drives indicated on the approved Bay West Cove Specific Plan. The development of common access drives is encouraged within Bay West Cove to minimize the number of curb cuts. Access drives should be coordinated with adjacent parcels so as not to impede the efficient flow of peak period traffic. Minimum two-way drive aisle width to be twenty five feet (25'-0") wide. d. Access drive designs should incorporate provisions for efficient vehicle stacking during peak periods of use. Major drive aisles from Oyster Point Boulevard or the primary roadway shall be a minimum of fifty-two feet (52') wide. The main access road will accommodate two ingress and two egress lanes which will be divided by a 5'-0" landscape planter. This four lane entry will reduce in width to two lanes as indicated in Figure No. 3. No parking will be permitted along either side of the main access road. Drive aisles provided at the entrance sides of proposed buildings shall be a minimum of twenty eight feet (28') wide. These aisles are intended for travel lanes and exclude parking field drive aisles. Drive aisles at the rear (service) sides of buildings shall be a minimum of twenty five feet (25') wide, pending the approval of the fire department. Dead-end drive aisles behind buildings shall be provided with a minimum 110 feet diameter turning area. h. All other drive aisles shall be per section 3.1.6. Dead end aisles shall be avoided within all driveway aisles designated for public access. November 7, 1997 Page 91 Bay West Cove Specific Plan South San Francisco, California 6.2 On Site 6.2.5 6.2.6 6.2.7 Circulation System - continued: Pedestrian Access A five foot (5'-0"') concrete walk shall be constructed along the southwest edge of the primary access road for pedestrian access, Crosswalks shall be located at strategic locations along this primary road to provide pedestrian access to the various developments. Bay West Cove shall be designed as a public environment, Pedestrian access into and throughout Bay West Cove shall comply with current ADA requirements - four foot (4'-0") minimum clearances along access ways. Transportation Access Refer to environmental impact report for transportation mitigation measures. No vehicle roadway connection will be made to the Sierra Point Site. Accessibility Guidelines Newly constructed multiple buildings on site shall have but are not limited to, the following features: f. g. h. i. j. Accessible machines, Refer to section Path of travel from public transportation point of arrival. Accessible routes of travel between buildings, Accessible parking. Ramps. Primary entrances. Accessible path of travel within buildings. Accessible sanitary facilities (restrooms). Accessible drinking fountains/telephones (when provided). Accessible features per specific occupancy requirements. special features (i.e. ATM's point of sales etc.). 5.1 for additional guidelines. November 7, 1997 Page 92 Bay West Cove Specific Plan South San Francisco, California 6.2 On Site Circulation System - continued 6.2.8. Service and Loading Areas a. Objectives To ensure that service and loading areas are not visible from streets, entry drives, common area spaces and recreational areas, etc. To ensure that service and loading areas are located within a site so as to minimize the visibility of loading and service vehicles from primary view areas. To ensure that the service and loading areas are designed and located on the site so that service vehicle activities and movement do not disrupt the efficient flow of-on-site and off-site traffic. b. Standards All loading facilities and maneuvering areas must be on site. All loading facilities shall be permitted only in the rear or side yard areas, refer to section 3.1.7. Aisle width to loading docks shall be a minimum of 30' (vedfy) wide. Loading docks shall be set back a minimum of 60' (verify) from the northerly right of way line of Bay West Cove Boulevard. Loading facilities shall be adequately screened from the public view through the use of screen walls and landscaping. Minimum aisle width adjacent to loading areas, without dock high doors, shall be 16' one way and 28' for two way. Provisions shall be made on each site for any necessary vehicle loading. On-street vehicle loading shall be prohibited. No street parking, staging and maneuvering by delivery trucks will be permitted in order to access loading docks unless within designated truck maneuvering areas. Truck dock and loading zones are subject to individual evaluation by the City of South San Francisco Traffic Department. November 7, 1997 Page 93 Bay West Cove Specific Plan South San Francisco, California 6.2 On Site Circulation System - continued 6.2.9 Refuse Collection Areas a. Objectives To ensure that refuse, refuse containers, trash compactors and recycling centers are not visible from primary visual exposure areas (streets, primary image entry drives, floors of image buildings, common visual and recreational amenity areas, etc.). To ensure that refuse enclosures are effectively designed to receive and contain generated refuse until collected, and enclose refuse containers after refuse is collected. To ensure that refuse collection vehicles have clear and convenient access to refuse collection areas thereby contributing to the long term maintenance and safety of this development. b. Standards All outdoor refuse containers shall be visually screened within a durable 6' - 0" or higher non-combustible enclosure, so as not to be visible from adjacent lots or sites, neighboring properties or streets. No refuse collection areas shall be permitted at the front of an in-line building. Refuse collection areas should be designed to contain all refuse generated on-site and deposited between collections.' Deposited refuse should not be visible from outside the refuse container. Refuse/recyclable collection enclosures should be designed of durable materials with finishes and colors which are compatible with the overall architectural theme. Refuse/recyclable enclosure shall be constructed per the city of South San Francisco and local solid waste collection company requirements. Refuse collection areas should be so located upon the site as to provide safe, clear and convenient access for refuse collection vehicles. Refuse collection areas should be designed and located to be convenient for the deposition of refuse generated on-site. November 7, 1997 Page 94 Bay West Cove Specific Plan South San Francisco, California 6.2 On Site Circulation System - continued 6.2.9 Bicycle Parking One bicycle parking area for every 50 parking stalls shall be provided in each tenant development. These bicycle parking areas shall be located convenient to the entrances of buildings to promote use. 7. INFRASTRUCTURE 7.1 Communication Devices 7.1.1 Objectives To have the entire Bay West Cove visually free of unsightly overhead power telephone lines, utility poles, and other utility and communication equipment and components. b. To protect off-site utility systems from becoming overburdened by individual site utility systems. To achieve minimum disruption of off-site utilities, paving, and landscaping during construction and maintenance of on-site utility systems. d. To eliminate the visibility of exterior electrical equipment and transformers from primary visual exposure areas. 7.1.2 Standards All exterior on-site utilities including, but not limited to, drainage systems, sewers, gas lines, water lines, and electrical (except transformers as addressed under Section 4.6), telephone and communications wires and equipment shall be installed and maintained underground. On-site underground utilities shall be designed and installed to minimize disruption of off-site utilities, paving and landscaping during construction maintenance and shall be designed not to place excessive burdens upon off- site utility systems during the course of use. No antenna or device for transmission or reception of any signals, including, but not limited to, telephone, television, and radio, shall be placed on any lot so that it is visible from 5' - 0" above the ground or ground floor level at a distance of 500 feet in any direction, unless specific written approval is granted by the city of South San Francisco. Transmitters and antennas shall be screened from view by walls, berms, and planting or a combination. November 7, 1997 Page 95 Bay West Cove Specific Plan South San Francisco, California 7.1 Communication Devices - continued: 7.1.2 Standards - continued Temporary overhead power and telephone facilities are permitted during construction. 7.2 Grading and Drainage 7.2.1 Objectives To encourage site design which protects buildings and business activities from damage or disruption that might otherwise occur during extreme storm conditions. To allow rain water falling on site and surface water flowing from adjacent sites to be effectively absorbed or to drain off the site without causing excessive water concentrations on adjacent sites or streets. c. To have site grading compliment and reinforce the overall architectural and landscape design character. 7.2.2 Existing Conditions~_ ae The Bay West Cove site is relatively flat east to west rising gently from elevation 1,5 to about elevation 40 in the southeast corner. The site is higher (elevation 12 to 13) along Oyster Point Boulevard sloping down to the north to elevation 5 around the water slot, with an average elevation of approximately elevation 8. The site is substantially lower than the neighboring property to the east. Previous use of the site has resulted in contaminated soils conditions in various areas, primarily around the water slot and in the southwest corner of the site. Numerous building foundations and foundation walls also remain from the previous industrial use of the site. ,4 Reimer Associates November 7, 1997 Page 96 Bay West Cove Specific Plan South San Francisco, California 7.2 Grading and Drainage - continued: 7.2.3 Proposed Grading Concept~ Two primary requirements establish the grading concept that is to be implemented for the site: drainage and encapsulation of contaminated soils. The site should be filled to elevations adequate to allow positive drainage in a 10-year storm occurring at the 100- year flood elevation established by FEMA (elevation 7.0). The city of South San Francisco requires that building floors be a minimum of 3 feet above the 100-year FEMA flood elevation. Encapsulation of the contaminated soils will be done by mixing the soils with dry cement or by such methods approved by the water board (RWQCB), spreading the fixated soils over controlled areas of the site and covering them with fill material (imported fill, pavement base and pavement) per remedial action plan. Where possible, utility corridors should be identified and isolated from the areas over which fixated soils are spread. 7.2.4 Proposed Drainage Concept~ Urbanization of the site will result in increased runoff. Drainage of the proposed development area would be by a combination of drainage swales and underground gravity pipelines. Planning Area 4 northwest of the slot would drain directly to the Bay through a new outfall near the large existing outfall north of the site. The remainder of the site would drain to a single ouffall into the bay near the existing site drainage outlet. 7.2.5 Grading and Drainage Guidelines~ Plan Area grading and drainage should be conducted to the following guidelines: Grading should be done in a manner as to preserve and enhance topographic features and provide positive drainage. b. Finished slopes should be a maximum of 2:1. '~ Reimer Associates ~6 Reimer Associates ,7 Reimer Associates November 7, 1997 Page 97 Bay West Cove Specific Plan South San Francisco, California 7.2 Grading and Drainage - continued: 7.3 7.2.5 Grading and Drainage Guidelines - continued:~ Berms, channels and swales should be graded in such a way as to be an integral part of the finished landscape or paved surface, and should be designed with smooth transitions between changes in slopes. Grading and drainage should take into consideration the control of drainage from off-site facilities and adjacent property. During construction the procedures outlined in the E.I.R. should be considered in order to minimize soil erosion by water and wind and to protect wetlands. Water~* 7.3.1 Background The site is provided water service by the California Water Service Company (CWSC). CWSC has recently installed a new 16-inch distribution line along Oyster Point Boulevard which will supply water to the site. The East of 101 Area Plan estimates that waste water generation within the Bay West Cove project could be expected to be at a rate of 80 percent of water demand. Therefore, with an estimated project waste water generation of 90,000 gallons per day, water demand is anticipated to be 113,000 gallons per day. Refer to E.I.R. for additional criteria. CWSC estimates that they have more than adequate water supply and system pressure to serve this demand from the Bay West Cove project. ,8 Reimer Associates ,9 Reimer Associates November 7, 1997 Page 98 Bay West Cove Specific Plan South San Francisco, California 7.3 Water - continued:'" 7.3.2 Water Distribution Water to the site will be provided from the existing 16-inch diameter water main in Oyster Point Boulevard. A new distribution main would be installed in a designated utility corridor following the planned main access road within the site. Service to individual building sites would be off this new distribution main. The new distribution main would be sized to convey the anticipated water demand and required fire flow. Sizing of the main would also depend on its final layout. CWSC has advised that the main could be sized based on either of two optional layouts: connection of the new main to the existing Oyster Point line and extension of the new main through the site to connect to an existing CWSC main north of the site resulting in a looped system, or increasing the size of the new main to avoid the need for the additional length to the north connection. Final selection would be based on a cost/benefit analysis of the two optional layouts. 7.3.3 Water Conservation Water conservation features should be incorporated into the Bay West Cove development including draught resistant landscaping and Iow flow plumbing fixtures. 7.4 Gas and Electric Service2' 7.4.1 The Plan Area is provided gas and electric service by Pacific Gas and Electric (PG&E). 7.4.2 PG&E has advised that area gas and electric generation and distribution facilities to the site are adequate to handle the development proposed. Gas and electric distribution facilities are available in Oyster Point Boulevard. 7.4.3 Gas, and electric service will be brought into the site from existing underground facilities in Oyster Point Boulevard. New facilities on site would be underground in a utility corridor following the main access road within the site. Individual services to building sites would be run underground from this utility corridor. ~o Reimer Associates 2, Reimer Associates November 7, 1997 Page 99 Bay West Cove Specific Plan South San Francisco, California 7.5 Telephone= 7.5.1 The site is provided telephone service by Pacific Bell. Pacific Bell has advised that their existing service facilities in Oyster Point Boulevard are of sufficient capacity to serve the proposed development. 7.5.2 New development will only be required to install copper cabling unless individual service needs demand the use of fiber optic cables for full motion video or high speed telecommunication lines. These lines, if required, are typically installed by individual users. 7.5.3 Telephone service will be brought into the site from existing underground facilities in Oyster Point Boulevard. New facilities on site would be underground in a utility corridor following the main access road within the site. Individual services to building sites would be run underground from this utility corridor. 7.6 Sanitary SeweF~ 7.6.1 Background The site is provided waste water collection service by the city of South San Francisco. Waste water treatment is provided at the city's Waste water Treatment Plant which also serves San Bruno and parts of Daly City. The city conducts an ongoing capital improvement program for the upgrade and maintenance of the collection and treatment facilities. Waste water generated within the site will be collected on site and discharged to the existing collection system in Oyster Point Boulevard. An on site pump station will be required to convey waste water off the site to the existing collections system. Final grading elevations will determine whether or not any of the site will be able to be served by gravity sewer to the existing system in Oyster Point Boulevard. 7.6.2 Waste water Collection The East of 101 Area Plan concludes that" ...sanitary sewer lines in the East of 101 Area have capacity to handle expected increases in flows form the allowed development...". The development plan for the site is = Reimer Associates = Reimer Associates November 7, 1997 Page 100 Bay West Cove Specific Plan South San Francisco, California 7.6 Sanitary Sewer - continued:~ 7.6.2 Waste water Collection - continued: anticipated to generate substantially lower waste water flows than had been estimated for previous development proposals for the area, thus impacting the existing collection system to a much lesser degree. Waste water flows generated in the development will flow by gravity or be pumped to the existing collection system in Oyster Point Boulevard. Flows are then conveyed through an existing sewer to the city's pump station No. 2 located on Gateway Boulevard. Waste water pumped from Pump Station No. 2 is conveyed through a force main in Gateway Boulevard and gravity sewers in Gateway Boulevard, Grand Avenue and Harbor Way to the city's Pump Station No. 4, from where it is pumped to the city's waste water treatment facility. A study was conducted by the city of South San Francisco in 1984 to evaluate the impact of a previous development proposal for the site. That study itemized existing collection system capacities and anticipated flows from tributary areas within the East of 101 Plan Area including the Gateway and the Oyster Point Business Park. 7.6.3 Waste water Treatment The East of 101 Area Plan conservatively sets the city's treatment plant capacity at 8.0 million gallons per day (mgd). The treatment plant currently receives an average daily flow of 7.34 million gallons. Anticipated flow from the Bay West Cove development is estimated at 0.09 mgd. This will bring the treatment plant inflow to 7.43 mgd, below its stated capacity. 24 Reimer Associates November 7, 1997 Page 101 Bay West Cove Specific Plan South San Francisco, California 8. PUBLIC SERVICES 8.1 Police Services The city of South San Francisco will provide full municipal law enforcement services to the proposed project. 8.2 Fire Prevention and Protection The project buildings shall be c~nstructed as fully sprinklered, per the requirements of the Uniform Building Code and comply with NFPA 13, current addition. On site fire hydrants shall be provided per the requirements of the fire deparh'nent. The city of South San Francisco will provide general fire fighting and emergency rescue services to the proposed project. Fire hydrants will be provided and maintained per the requirements of California Water Service and the Uniform Fire Code Appendix III-B & Ill-BB. 8.3 Solid Waste Disposal Solid waste disposal will be provided by South City Scavengers and will comply with their established requirements. November 7, 1997 Page 102 Bay West Cove Specific Plan South San Francisco, California 9. ADMINISTRATION/IMPLEMENTATION 9.1 General methods to implement The Bay West Cove Specific Plan shall be implemented through the review of precise plans, which shall set forth in detail development guidelines for proposed structures and improvements and their arrangements within the specific plan area; parcel maps; design review; and sign permits. The Redevelopment Agency shall review precise plans submitted for approval to determine whether they are consistent with the a Bay West Cove Specific Plan, the redevelopment plan, and the owner participation agreement. 9.2 Precise Plans 9.2.1 When required No person shall commence any use or erect any structure or make exterior modifications to any existing use, parking area or structure, and no building permit, or certificate of occupancy shall be issued for any new use or structure or modifications thereof until a Precise Plan therefore has been approved in accordance with the requirements set forth in sections 9.2.2 through 9.6. The following shall not require prior approval of a Precise Plan: Change in sign copy on existing changeable signs or on signs designed to allow a change of copy; Changes required in whole or in part by a requirement of any governmental agency; 9.2.2 Application for review Preapplication Meeting: Schedule at your convenience a pre- application meeting with a South San Francisco City Planner to review proposed development and determine submittal requirements. Application Submittal: Applications may be submitted to the City Of South San Francisco at any time, however the deadline for the planning cycle is the first Friday of each month. 9.2.3 Contents The following information and drawings shall be required for consideration by the Redevelopment Agency, except that the executive director of the Redevelopment Agency may require lesser information or fewer drawings if in his opinion the information and drawings submitted meet the intent and purpose of this section; or, the executive director of the Redevelopment Agency may require additional information if November 7, 1997 Page 103 Bay West Cove Specific Plan South San Francisco, California 9.2.4 9.2.5 such additional information is necessary to meet the intent and purpose of this section. All applicable tentative, final or parcel maps within the area covered by the proposed Precise Plan; A legal and physical description of the site including boundaries, easements, existing topography, natural features, existing buildings, structures and utilities; A plot or site plan, drawn to scale which depicts all proposed on-site improvements and utilities and the locations of same in accordance with the standards established in the Bay West Cove Specific Plan; A landscape plan drawn to scale which sets forth information pertinent to the landscape requirements of the Bay West Cove Specific Plan and the zoning ordinance and shows all existing trees and shrubs on the site; Eo Grading and drainage plans unless the city engineer determines they are unnecessary for the review process; Fo Architectural plans and exterior elevations indicating profiles, glazing and materials drawn to scale. The applicant shall submit one colored full-size print showing elevations drawn to scale and ten 8-1/2" x 11" reductions showing all land uses and buildings; G. Scale drawings of all signs and light standards with details of height, area, color and materials specified therein; Any other drawings or additional information necessary for the Redevelopment Agency to review and make its determinations required hereby. Design Review Each application for a Precise Plan shall be referred to the Design Review Board, which shall formulate a recommendation to the Agency. Redevelopment Agency action Guidelines for review: In reviewing Precise Plans pursuant to the Bay West Cove Specific Plan, the Redevelopment Agency shall adhere to the standards set forth herein and shall further attempt to foster and promote the general character and purposes of the Specific Plan area set forth in the redevelopment plan and the owner participation agreement. November 7, 1997 Page 104 Bay West Cove Specific Plan South San Francisco, California 9.2.6 9.2.7 Period of review: To ensure the orderly development and marketing of property in the specific plan area, the Redevelopment Agency shall act promptly on any request for its approval. The executive director of the Redevelopment Agency shall review the application in light of the guidelines and standards set forth herein and shall consult with the staff of affected departments and offices of the city in connection with the review of each Precise Plan. Upon completion of his review and consultations, the executive director shall submit the Precise Plan to the board of the Redevelopment Agency and shall recommend that the board of the Redevelopment Agency approve, conditionally approve, disapprove or suggest modifications to the Precise Plan. The Redevelopment Agency shall approve, conditionally approve, disapprove or suggest modifications to the Precise Plan. Any conditions shall be reasonable, and designed to assure attainment of the standards established in Section 9.2.4. No approval shall be unreasonably withheld by the board if the Precise Plan shall be within the standards set for in Section 9.2.4. If the board disapproves the Precise Plan, it shall specify the standards or conditions which have not been met. Changes after approval If significant changes to an approved Precise Plan are desired by the applicant, a revised Precise Plan shall be submitted and processed according to the procedures established herein for approval of the original Precise Plan. Revisions which are minor in nature, other than those applied as a condition of approval, shall be reviewed and approved by the executive director of the Redevelopment Agency. Mandatory findings The board of the Redevelopment Agency shall make the following findings before approving or conditionally approving any Precise Plan. The project proposed in the Precise Plan is compatible with the intent and purpose of the Bay West Cove Specific Plan. The proposed development and/or construction standards of the Precise Plan are designed to achieve compliance with the development and/or construction standards of the Bay West Cove Specific Plan. November 7, 1997 Page 105 Bay West Cove Specific Plan South San Francisco, California The project proposed in the Precise Plan is consistent with the redevelopment plan and the owner participation agreement. The project proposed in the Precise Plan is consistent with the East of 101 Plan. 9.3 Conditional Use Permits 9.3.1 Applicability A Conditional Use Permit shall be approved by the Redevelopment Agency for drive-up and drive-through restaurants within the Bay West Cove Specific Plan area. 9.3.2 Applications Applications for Conditional Use Permits shall be filed with the South San Francisco Planning Division, on forms specified by the Division. Applications shall be accompanied by required fees, plans and other material as determined by the Planning Division. 9.3.3 Notice, Hearing, Findings and Approval Applications for Conditional Use Permits shall be considered at a public hearing held before the Redevelopment Agency. Notice of said hearing shall be given in a manner as specified in the South San Francisco Municipal Code. Conditional Use Permits may be approved, conditionally approved or denied by the Agency. If approved or conditionally approved, findings shall be made by the Agency as specified in the South San Francisco Municipal Code. 9.4 Parcel Maps 9.4.1 Parcel maps may be filed for the purpose of sale, lease or finance of property. 9.4.2 Contents of parcel map shall be identified by the City of South San Francisco Planning and Engineering Departments 9.4.3 Parcel maps shall be reviewed and approved by the Planning Commission in conformity with the State Subdivision Map Act and local subdivision map requirements. 9.5 Sign Permits 9.5.1 All signage shall comply with the standards of the Bay West November 7, 1997 Page 106 Bay West Cove Specific Plan South San Francisco, California Cove Planned Sign Program. 9.5.2 No sign shall be constructed or installed without a permit from the City Planning Department and written approval from the landlord. 9.5.3 Sign permits are required for all new signs and change of face for existing signs. A sign permit application must be filed with the City Planning Department and must be signed by both the business owner and property owner. Sign permit applications and instructions concerning required exhibits are available from the Planning Department. 9.5.4 All pylon signs and wall signs shall be approved as part of a precise plan by the Redevelopment Agency. 9.5.5 Minor signs, including new signs containing less than 25 sq.ft, of copy area and change of copy for any existing sign shall require a Type A permit, to be issued by the Planning Department. In cases not covered by this sign program, the City of South San Francisco Zoning Ordinance and the East 101 Area Plan shall apply. 9.6 Environmental Review , 9.6.1 9.6.2 All development within the Plan Area is subject to the mitigation measures identified in the Bay West Cove Environmental Impact Report. · As provided for in State Law, certain projects may be exempt from further environmental review when: The project is consistent with the Specific Plan, and the Environmental Impact Report. The EIR adequately identified the project's significant environmental effects and corresponding mitigation measures. The City has determined the type of environmental document needed in accordance with the requirements of the California Environmental Quality Act, and has given notice of such fact as required by State Law, and the City of South San Francisco Implementing Procedures. 9.6.3 All future Precise Plans, parcel maps and sign permits within the Bay West Cove site have been obtained through the adoption of the Bay West Cove EIR. However, future amendments to the Specific Plan may require additional environmental determinations. November 7, 1997 Page 107 Bay West Cove Specific Plan South San Francisco, California 9.7 Amendments to the Specific Plan 9.7.1 The procedure for amending the Bay West Cove specific plan shall be as specified in the California Government Code, Sections 65500 through 65507. Prior to approving any amendment to the Bay West Cove Specific Plan, the City Council shall find that: The amendment is consistent with the redevelopment plan and the owner participation agreement. 2. The amendment is consistent with the general plan. November 7, 1997 Page 108 RESOLUTION NO. 137-97 ATTACHlV[ENT 2 TO BAY WEST COVE SPECIFIC PLAN RESOLUTION Bay West Cove Specific Plan December 10, 1997 1) 2) 3) 4) s) 6) 7) Approval is hereby granted for the Bay West Cove Specific Plan, dated November 7, 1997, prepared by MCG Architects. Any development in excess of the amount square footage and/or number of lodging rooms may require an amendment to the Specific Plan. All environmental mitigations contained in the Draft and Final Environmental Impact Reports shall be adhered to, as specified in the Mitigation Monitoring and Reporting Program for the Bay West Cove project. The applicant shall deposit sufficient funds with the City of South San Francisco to retain the services of a qualified consultant to administer and implement the Mitigation Monitoring and Reporting Program approved as part of the project. Figure 11 within the Plan shall be modified to provide for a minimum dimension of landscaping of 15 feet for buildings greater than fifty (50) feet in height. Pedestrian pathways, driveways and porte cocheres may be allowed within this landscaped area as part of the Design Review process. The primary entry drive (Bay West Cove Boulevard) at the intersection of Oyster Point Boulevard, shall be a minimum of 58 feet in width, curb-to-curb. This width shall include two 13-foot wide travel lanes in each direction and a six-foot wide raised median island in the center of the roadway. Section 4.2 (Design Standards) shall be modified to address the relationship between buildings, service areas/loading faciBties, outdoor sales and service area and the bay front. Section 7 (Administration/Implementation) shall be modkfied to include information as to submittal and approval requirements for "Discretionary Permits" which are required by the East of 101 Plan under certain specified conditions. 8) The Sign program should be amended to include special signs for visitors at the Bay Trail viewing plazas. The design of the sign shall be approved by the Police department and Planning Division. 9) All site lighting shall be controlled by photocell and shall remain on during the hours of OOGO ! lo) 12) 14) diminished natural lighting. The Bay Trail linkage shall accommodate emergency vehicles as determined by the Police and Fire Departments. This shall include providing a minimum 12-foot wide pathway, sufficiently large to accommodate emergency vehicles, ffthe pathway is less than 12 feet, emergency access points shall be provided every 500 feet along the pathway and appropriately marked. Section 4.2.2 shall be amended to note that no wing walls or other design elements that would provide lighting dead space or hiding spaces shall be installed. The following language shall be added to the sign program: "No sign shall be erected along any street or parking aisle in such a manner that portions of the sign support or mounting base obstructs'or interferes with the sight distance of any vehicle traveling on a street, an intersecting street, parking aisle, intersecting parking aisle or driveway access to any street or parking aisle. No sign shall be posted so close to an intersection that a motorist must move the fxont of the vehicle past the prolongation of the intersecting curb line in order to view any cross traffic which may be approaching from the right or left on the intersecting street or parking aisle or driveway which enters any street or paring aisle." The height of any landscaping within street medians shall not exceed three feet. A standard shall be added to the transportation section noting that pedestrian sidewalks shall be provided on at least one side of every major roadway and that mid-block pedestrian crossings shall be avoided. The applicant shall submit fifty (50) final bound copies of the Bay West Cove Specific Plan document, incorporating all of the above changes and modifications, to the Planning Division within sixty days following final approval by the City Council, or prior to submittal of the first Precise Plan, whichever comes first. In addition to the fifty copies, one unbound copy and one electronic copy shall be provided to the Planning Division. Prior to the issuance of grading permits or recordation of a parcel map on the rite, whichever occurs first, the applicant shall submit information to the Engineering Department identifying specific project vehicular trip generation at surrounding intersections. This is for the purpose of determining traffic impact fee calculation. The applicant shall pay a fair share cost of extending the Bay Trail to the most northerly portion of the Bay West Cove site. 00 1