Loading...
HomeMy WebLinkAboutReso 31-2014 Exhibit ADraft Entitlements Resolution - Exhibit A Conditions of Approval 13 CONDITIONS OF APPROVAL P11 -0065: UP11 -0006, DR11 -0019, TDM13 -0001, DA13 -0002 & ND12 -0004 180 EL CAMINO REAL (As recommended by City Staff on March 12, 2014) A) Planning Division requirements shall be as follows: The applicant shall comply with the Planning Divisions standard Conditions and Limitations for Commercial, Industrial, Mixed -Use and Multi - Family Residential Projects. 2. The project shall be constructed and operated substantially as indicated on the plan set prepared by Johnson Lyman Architects, dated August 1, 2013. 3. The applicant shall comply with all mitigation measures outlined in the Mitigation Monitoring and Reporting Program (MMRP) for the 180 El Camino Real Project. 4. All equipment (either roof, building, or ground- mounted) shall be screened from view through the use of integral architectural elements, such as enclosures or roof screens, and landscape screening or shall be incorporated inside the exterior building wall. Equipment enclosures and /or roof screens shall be painted to match the building. Prior to issuance of a building permit the applicant shall submit plans showing utility locations, stand- pipes, equipment enclosures, landscape screens, and /or roof screens for review and approval by the Chief Planner or designee. 5. No signs are included in this permit application. Prior to installation of any signage, the applicant shall submit a comprehensive Master Sign Program for appropriate review and approval by the Chief Planner or designee. 6. Prior to issuance of any building or construction permits, the applicant shall submit interim and final phasing plans and minor modifications to interim and final phasing plans for review and approval by the Chief Planner, City Engineer and Chief Building Official. 7. Prior to issuance of any building or construction permits for the construction of public improvements, the final design for all public improvements shall be reviewed and approved by the City Engineer and Chief Planner. Prior to issuance of any building or construction permits for grading improvements, the applicant shall submit final grading plans for review and approval by the City Engineer and Chief Planner. 9. Prior to issuance of any building or construction permits for landscaping improvements, the applicant shall submit final landscaping and irrigation plans for review and approval by the Chief Planner. The plans shall include documentation of compliance with SSFMC § 20.300.007 "Landscaping ", including Water Efficient 14 Landscaping and Irrigation calculations and shall be consistent with the intent of the El Camino Real Master Plan. 10. Prior to issuance of any building or construction permits, the applicant shall submit a "Parking and Loading Management Plan ", a "Trash Management Plan" and a "Shopping Cart Management Plan" for review and approval by the Chief Planner or designee. 11. All parking areas are to be maintained free and clear of litter and storage and shall remain clear for parking at all times. No outdoor storage of materials is allowed. 12. Prior to issuance of any building or construction permits, the developer shall revise the development plans to address the following Design Review Board comments related to Phase 1, subject to review and approval by the Chief Planner or designee: a) Revise the roof treatment to be more prominent over the primary Safeway and Major 2 entrances on the north elevation. The higher mansard roofs should be integrated with the lower mansard roofs at the building setback ends. b) Include additional patterns and textures on the ground floor facades to provide more interest at the pedestrian scale. c) Provide landscaping (trellis structures, planter boxes, etc.), lighting, and material /color texturing on the 2nd floor parking levels/ roof area of Safeway/Major 2 and the Health Club. d) Provide additional architectural and /or landscape treatment along the south elevation of the Safeway/Major 2 building to provide more visual interest. 13. Prior to issuance of any building or construction permits, the developer shall revise the development plans to address the following design related comments, subject to review and approval by the Chief Planner or designee: a) Revise the west CVS building wall so that the maximum length of blank wall is no greater than forty (40) feet and provide enhanced landscaping within the setback from El Camino Real adjacent to the southern portion of the west CVS building wall. b) Landscape the surface parking lot proposed in the future location of Building E and the Parking Structure to match the remainder of the surface parking lot as approved in the project plans. c) Provide enhanced landscaping adjacent to the Safeway parking ramp, including a mixture of shrubs, trees and growing vines, to properly screen the ramp wall. 15 14. Prior to issuance of any building or construction permit for commercial uses and prior to occupancy for residential uses, the applicant shall pay any applicable childcare fees in accordance with South San Francisco Municipal Code Chapter 20.115. This fee is subject to annual adjustment, and presently is assessed at $1,851.00 per high density residential unit and $.68. per gross square foot for commercial /retail. 15. The applicant has prepared and submitted a draft Preliminary TDM Plan. In accordance with South San Francisco Municipal Code Chapter 20.400, prior to issuance of a building permit the applicant shall submit a Final TDM Plan for review and approval by the Chief Planner. The Final TDM shall comply with SSFMC Chapter 20.400. a) The Final TDM Plan shall include all mandatory elements included in the Ordinance and shall substantially reflect the Preliminary TDM Plan prepared by TJKM. The Plan shall be designed to ultimately achieve a goal of 28% alternative mode usage by employees within the Project. b) The Final TDM Plan shall outline the required process for on -going monitoring, including annual surveys. The initial annual survey will be submitted one (1) year after the granting of a certificate of occupancy. The initial annual survey shall either: (1) state that the applicable property has achieved 28% alternative mode usage, providing supporting statistics and analysis to establish attainment of the goal; or (2) state that the applicable property has not achieved the 28% alternative mode usage, providing an explanation of how and why the goal has not been reached, and a description of additional measures that will be adopted in the coming year to attain the TDM goal of 28% alternative mode usage. c) The applicant shall be required to reimburse the City for program costs associated with monitoring and enforcing the TDM Program. 16. Developer must apply for the building permit for the Phase 1 Safeway/Major 2 commercial building, not including CVS concurrently with the building permit for the 150 Phase 1 residential units. The Safeway/Major 2 commercial building not including CVS and 150 unit residential building permits will only be issued concurrently. 17. The building permits issued for all Phase 1 commercial buildings shall provide that no certificate of occupancy for any such commercial building will be issued until construction of Phase 1 residential units, defined as vertical wall framing of residential units, has been commenced. Planning Division contact: Billy Gross, Associate Planner (650) 877 -8535 B) Fire Department requirements shall be as follows: 16 Prior to issuance of a building permit the applicant shall submit plans showing the following improvements for review and approval by the Fire Marshal or designee: a) Install fire sprinkler system per NFPA 13 /SSFFD requirements under separate fire plan check and permit for overhead and underground. b) Fire sprinkler system shall be central station monitored per California Fire Code section 1003.3. c) Install a standpipe system per NFPA 14 /SSFFD requirements under separate fire plan check and permit. d) Install exterior listed horn/strobe alarm device, not a bell. e) Elevator shall not contain shunt - trips. f) At least one elevator per building shall be sized for a gurney the minimum size shall be in accordance with the CFC. g) Fire alarm plans shall be provided per NFPA 72 and the City of South San Francisco Municipal Code. h) Buildings 4 stories or more will require a modified smoke control system. A rational analysis is required before building plans are approved. i) Plans are to conform to Building codes and the City of South San Francisco Municipal Code. Section 15.24.130. j) Provide fire extinguishers throughout the building. k) All Non parking space curbs to be painted red to local Fire Code Specifications. 1) Access road shall have all weather driving capabilities and support the imposed load of 75,000 pounds. m) Road gradient and vehicle turning radius shall not exceed maximum allowed. n) Provide fire flow in accordance with California Fire Code Appendix III -A. o) Provide fire hydrants with an average spacing of 400 feet between hydrants; location and number to be determined. p) All buildings shall provide premise identification in accordance with SSF municipal code section 15.24.100. 17 q) Provide Knox key box for each building with access keys to entry doors, electrical /mechanical rooms, elevators, and others to be determined. r) The minimum road width is 20 feet per the California Fire Code. s) All buildings shall have Emergency Responder Radio Coverage throughout in compliance with Section 510 of the California Fire Code. Fire Prevention contact: Luis DaSilva, Fire Marshal (650) 829 -6645 C) Engineering Division requirements shall be as follows: The development shall comply with the "Standard Development Conditions for Commercial and Industrial Developments ", copies of which are available from the Engineering Division. 2. The building permit application plans shall conform to the standards of the Engineering Division's "Building Permit Typical Plan Check Submittals" requirements, copies of which are available from the City Engineer's Office. 3. The owner shall hire a licensed land surveyor or civil engineer authorized to practice land surveying to certify that the new foundation forms conform with all setbacks from confirmed property lines and that all easements are verified and in conformance with the plans. A letter certifying the foundation forms shall be submitted to the Engineering Division for approval. 4. The developer shall submit a geotechnical report along with a cash deposit of $5,000 for peer review. The geotechnical report shall also include, but not limited to, design criteria for the subterranean parking area, footing /foundations of the future structures, etc. 5. The developer shall coordinate the signal light timing along Spruce Avenue and the El Camino Real signal light, which may include installation of conduit and upgrades to the existing signal lights. Any improvements constructed on El Camino Real shall be approved by Caltrans. All improvements shall be designed by a registered civil engineer and approved by the Engineering Division. 6. Any grading over 50 cubic yards shall require a grading permit. The grading plan should clearly state the amount of cut and fill required to grade the project. The developer shall apply for the grading permit with the Engineering Division and shall submit an application, all documentation, fees, deposits, bonds and all necessary paperwork needed for the application. The developer shall place an initial $30,000 cash deposit with the City for environmental compliance inspection personnel time, which includes, but not limited to, air quality, grading and storm water pollution inspections. 110 7. The developer shall, at his/her expense, design and construct a drainage system that will route storm water run -off from all areas towards the public storm drainage system. The storm drainage plan shall be designed by a licensed civil engineer. In addition to the drainage plan, the developer shall submit all drainage calculations and pre - and post - construction run -off calculations. The storm drainage pipes shall be sized for a 10 -year, 5 -min storm. Any off -site improvements shall be designed by a licensed civil engineer, be at no cost to the City and shall be reviewed and approved by the Engineering Division. The existing 10" sewer main is a major trunk for the City. It shall be relocated to South Spruce Avenue. In addition, only one service connection to the city's sewer main per parcel is allowed. The plans currently showing two connections. 9. The developer, at his/her own expenses, shall provide flow study for both storm water and sewer system to justify if the existing city facilities will be sufficient to support the development. 10. The bio- detention along the back of sidewalk on South Spruce Avenue is shown to be constructed on top of the 60- inches storm main with the City's easement. Shall the city need to access the storm main, the owner shall be responsible for restoring the bio - detention. 11. Prior to the issuance of a building permit, the applicant shall revise Sheet C4. Ito show Section B -B in the correct location. In addition, retaining wall on top of the 60- inches storm main is not allowed. 12. The developer shall remove and replace all sidewalk and broken curb and gutter at his/her own expense. The developer shall install all required standard accessible ramps and appurtenances related to pedestrian use. Driveways shall not be greater than a 12% grade. 13. Developer shall coordinate with the California Water Service for all water - related issues. They can be contacted at (650) 558 -7800. 14. Any work performed in the City's right -of -way shall require an encroachment from the Engineering Division. The owner shall apply and pay all fees and deposits for the encroachment permit. Engineering Division contact: Andy Tan, Senior Engineer (650) 829 -6652 D) Police Department requirements shall be as follows: 19 Municipal Code Compliance. The applicant shall comply with the provisions of Chapter 15.48 of the Municipal Code, "Minimum Building Security Standards" Ordinance revised May 1995. The Police Department reserves the right to make additional security and safety conditions, if necessary, upon receipt of detailed / revised building plans. Police Department contact: Sergeant Scott Campbell (650) 877 -8927 E) Water Quality Control Plant requirements shall be as follows: A plan showing the location of all storm drains and sanitary sewers must be submitted. 2. Encourage the use of pervious pavement where possible. 3. The onsite catch basins are to be stenciled with the approved San Mateo Countywide Stormwater Logo (No Dumping! Flows to Bay). 4. Any food service establishments must install a grease removal device. The grease removal device must be connected to all wash sinks, mop sinks, and floor sinks and must be upstream of the domestic waste stream. Sizing of the grease removal device must be in accordance with the uniform plumbing code. The minimum size shall be no less than 750 gallons. This must be shown on the plans prior to the issuance of a permit. 5. A signed maintenance agreement for the grease removal device must be submitted prior to the issuance of a permit. 6. Source Control Requirements. The project must implement source control measures onsite that at a minimum shall include the following: a) Minimization of stormwater pollutants of concern in urban runoff through measures that may include plumbing of the following discharges to the sanitary sewer, subject to the local sanitary sewer agency's authority and standards: i. Discharges from indoor floor mat/equipment/hood filter wash racks or covered outdoor wash racks for restaurants; ii. Dempster drips from covered trash, food waste and compactor enclosures; iii. Discharges from covered outdoor wash areas for vehicles, equipment, and accessories; iv. Fire sprinkler test water, if discharge to onsite vegetated areas is not a feasible option; b) Properly designed covers, drains, and storage precautions for outdoor material storage areas, loading docks, repair /maintenance bays, and fueling areas; 20 c) Properly designed trash storage areas; d) Landscaping that minimizes irrigation and runoff, promotes surface infiltration, minimizes the use of pesticides and fertilizers, and incorporates other appropriate sustainable landscaping practices and programs such as Bay - Friendly Landscaping; e) Efficient irrigation systems; and f) Storm drain system stenciling or signage. 7. Implement Site Design and Stormwater Treatment Requirements The project must implement at least the following design strategies onsite: a) Limit disturbance of natural water bodies and drainage systems; minimize compaction of highly permeable soils; protect slopes and channels; and minimize impacts from stormwater and urban runoff on the biological integrity of natural drainage systems and water bodies; b) Conserve natural areas, including existing trees, other vegetation, and soils; c) Minimize impervious surfaces; d) Minimize disturbances to natural drainages; and e) Minimize stormwater runoff by implementing one or more of the following site design measures: i. Direct roof runoff into cisterns or rain barrels for reuse. ii. Direct roof runoff onto vegetated areas. iii. Direct runoff from sidewalks, walkways, and/or patios onto vegetated areas. iv. Direct runoff from driveways and /or uncovered parking lots onto vegetated areas. v. Construct sidewalks, walkways, and/or patios with permeable surfaces. vi. Construct driveways, bike lanes, and/or uncovered parking lots with permeable surfaces. Stormwater from the entire project must be included in the treatment system design. ( Stormwater treatment systems must be designed to treat stormwater runoff from the entire project.) The project is required to treat 100% of the amount of runoff identified in provision C.3.d for the Regulated Project's drainage area with LID treatment measures onsite or with LID treatment measures at a joint stormwater treatment facility. 21 a) LID treatment measures are harvesting and re -use, infiltration, evapotranspiration, or biotreatment. b) A properly engineered and maintained biotreatment system may be considered only if it is infeasible to implement harvesting and re -use, infiltration, or evapotranspiration at a project site. c) Infeasibility to implement harvesting and re -use, infiltration, or evapotranspiration at a project site may result from conditions including the following: i. Locations where seasonal high groundwater would be within 10 feet of the base of the LID treatment measure. ii. Locations within 100 feet of a groundwater well used for drinking water. Treatment devices must be sized according to the WEF Method or the Start at the Source Design. Please state what method is used to calculate sizing. The applicant must submit a signed Operation and Maintenance Information for Stormwater Treatment Measures form for the stormwater pollution prevention devices installed. 9. The applicant must submit a signed maintenance agreement for the stormwater pollution prevention devices installed. Each maintenance agreement will require the inclusion of the following exhibits: a) A letter -sized reduced -scale site plan that shows the locations of the treatment measures that will be subject to the agreement. b) A legal description of the property. c) A maintenance plan, including specific long -term maintenance tasks and a schedule. It is recommended that each property owner be required to develop its own maintenance plan, subject to the municipality's approval. Resources that may assist property owners in developing their maintenance plans include: i. The operation manual for any proprietary system purchased by the property owner. 10. The owner or his representative must file this agreement with the County of San Mateo and documentation that the County received it must be sent to the Technical Services Supervisor. 11. Applicant must complete the Project Applicant Checklist and C3 and C6 Data Worksheet prior to issuance of a permit and return to the Technical Services Supervisor at the WQCP. 22 12. Condensate and /or blowdown from rooftop equipment must be routed to the sanitary sewer. 13. If there is underground parking, water from the groundwater infiltration/foundation drain must be plumbed to the sanitary sewer. 14. Landscaping shall meet the following conditions related to reduction of pesticide use on the project site: a) Where feasible, landscaping shall be designed and operated to treat stormwater runoff by incorporating elements that collect, detain, and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolonged exposure to water shall be specified. b) Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency and plant interactions to ensure successful establishment. c) Existing native trees, shrubs, and ground cover shall be retained and incorporated into the landscape plan to the maximum extent practicable. d) Proper maintenance of landscaping, with minimal pesticide use, shall be the responsibility of the property owner. e) Integrated pest management (IPM) principles and techniques shall be encouraged as part of the landscaping design to the maximum extent practicable. Examples of IPM principles and techniques include: i. Select plants that are well adapted to soil conditions at the site. ii. Select plants that are well adapted to sun and shade conditions at the site. In making these selections, consider future conditions when plants reach maturity, as well as seasonal changes. iii. Provide irrigation appropriate to the water requirements of the selected plants. iv. Select pest- resistant and disease - resistant plants. v. Plant a diversity of species to prevent a potential pest infestation from affecting the entire landscaping plan. vi. Use "insectary" plants in the landscaping to attract and keep beneficial insects. 15. No decorative bark shall be used in landscaping. 16. Trash handling area must be covered, enclosed and must drain to sanitary sewer. This must be shown on the plans prior to issuance of a permit. 23 17. Install a separate water meter for each commercial unit. 18. Install a separate water meter for landscaping. 19. A construction Storm Water Pollution Prevention Plan must be submitted and approved prior to the issuance of a permit. 20. Plans must include location of concrete wash out area and location of entrance /outlet of tire wash. 21. A grading and drainage plan must be submitted. 22. An erosion and sediment control plan must be submitted. 23. Applicant must pay sewer connection fee at a later time based on anticipated flow, BOD and TSS calculations. 24. Must file a Notice of Termination with the WQCP when the project is completed Water Quality contact: Rob Lecel (650) 877 -8555 2249211.1 24 Draft Entitlements Resolution - Exhibit C Project Plans (Download as Separate File on Website) 25